Abstract
With emerging new developments in the scope of the Bio-Impedance Measurement System (BIMS), an automated test of the data acquisition equipment and its proper tuning in conditions of strict accuracy requirements have become a critical issue. Such BIMS, as the one designed by ELIKO Competence Centre and Artec Design LLC, is basically a complex synchronous data acquisition platform, with the base elements being a sine wave excitation signal generator, a multi-channel sampler and a DSP unit. Such a system requires full testing and calibration prior to conducting complicated and expensive biomedical experiments. Thus, the solution was selected, where the observable biological system is replaced with a digitally controlled resistance and capacitance array (DCRCA) during the testing and calibration process. DCRCA is the part of the proposed digitally controlled reference impedance device (DCRID), which emulates the behaviour of biological tissue in a determined manner. The parameter variation is supervised by a microcontroller, which enables to change properties of DCRCA with high resolution and exact timing.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Poola G, Toomessoo J (2007) Inherently synchronous data acquisition as a platform for bioimpedance measurement. 11th Mediterranean Conference on Medical and Biological Engineering and Computing, to be published.
EBI-Box and EBI-Phantom developed by MESEL at http://www.elin.ttu.ee/BME-Lab/Equipmnt/Biomedic/
Analog Devices, Inc. Analog switches and multiplexers at http://www.analog.com
Maxim Integrated Products, Inc. Analog switches and multiplexers at http://www.maxim-ic.com
Mayes L (2002) Using a FET as a voltage controlled resistor, 18 Oct 2002, URL: http://freespace.virgin.net/ljmayes.mal/comp/vcr.htm
Senani R (1994) Realisation of linear voltage-controlled resistance in floating form. Electronic Letters 30(23):1909-1911 10th Nov 1994
Kushima M, Inaba M, Tanno K, Ishizuka O (2004) Design of a floating node voltage-controlled linear variable resistor circuit. Circuits and Systems, 2004. MWSCAS ’04 pp. I- 85-8 vol.1
Geiger R, Sánchez-Sinencio E (1985) Active filter design using operational trans-conductance amplifiers: a tutorial. IEEE Circuits and Devices Magazine 1:20-32
Miller J (1920) Dependence of the input impedance of a three-electrode vacuum tube upon the load in the plate circuit. Scientic Papers of the Bureau of Standards 15(351):367-385 Scanned at http://web.mit.edu/klund/www/papers/jmiller.pdf
Gumstix, Inc. at http://www.gumstix.com
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Birjukov, A., Krivoshei, A., Parve, T. (2007). Digitally Controlled Reference Impedance Device for Test and Calibration of the Bio-Impedance Measurement System (BIMS) in a Networked Environment. In: Scharfetter, H., Merwa, R. (eds) 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography. IFMBE Proceedings, vol 17. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73841-1_73
Download citation
DOI: https://doi.org/10.1007/978-3-540-73841-1_73
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-73840-4
Online ISBN: 978-3-540-73841-1
eBook Packages: EngineeringEngineering (R0)