The aim of this study was to compare equilibrated urea Kt/V (eKt/V) from the slope of the logarithmic online UV-absorbance measurements measured by the Dialysis Adequacy Monitor (DIAMON), by eKt/V obtained from a new algorithm that can be implemented into the DIAMON prototype. As the reference the urea eKt/V was utilized obtained from the blood samples according to the rate adjustment method. The mean value of equilibrated Kt/V obtained with UV-absorbance (eKt/Va) was 1.06 ± 0.21, using the new algorithm (eKt/Vn) was 1.09 ± 0.18, and eKt/V from blood-urea (eKt/Vb) 1.09 ± 0.20 (N = 21). The mean values of eKt/V were not statistically different comparing different methods. However, both the systematic and the random error were diminished by the new algorithm. The systematic error was decreased from 2.19% to 0.312%, and the random error was decreased from 14.37% to 7.30% using the new algorithm. In summary, the DIAMON prototype can accurately and on-line estimate the dialysis dose.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
NKF K/DOQI guidelines. CLINICAL PRACTICE GUIDELINES FOR HEMODIALYSIS ADEQUACY, UPDATE 2006. at http://www.kidney.org/professionals/KDOQI/guideline_upH D_PD_VA/index.htm.
Port F K, Ashby V B, Dhingra R K, Roys E C and Wolfe R A (2002) Dialysis dose and body mass index are strongly associated with survival in hemodialysis patients. Journal of the American Society of Nephrology 13:1061–1066
Locatelli F, Buoncristiani U, Canaud B, Khler H, Petitclerc T and Zucchelli P (2005) Haemodialysis with on-line monitoring equipment: tools or toys? Nephrology Dialysis Transplantation 20:22–33
Fridolin I, Magnusson M and Lindberg L-G (2002) On-line monitoring of solutes in dialysate using absorption of ultraviolet radiation: technique description. The International Journal of Artificial Organs 25:748–761
Uhlin F, Fridolin I, Lindberg L-G and Magnusson M (2003) Estimation of delivered dialysis dose by on-line monitoring of the UV-absorbance in the spent dialysate. American Journal of Kidney Diseases 41:1026–1036
Fridolin I, Uhlin F, Magnusson M and Lindberg L-G (2006) Accurate Estimation of Delivered Dialysis Dose by On-Line Ultra Violet Absorbance in the Spent Dialysate. Nephrol Dial Transplant. Vol 21:ERA/EDTA XLIII Congress (abstract), Glasgow
Daugirdas J T (1995) Simplified equations for monitoring Kt/V, PCRn, eKt/V, and ePCRn. Advances in Renal Replacement Therapy 2:295–304
Fridolin I and Uhlin F, 'Device for Dialysis Quality Parameters, Utility Model nr. EE 00620 U1. Estonia, 2006.
Fresenius, OCM. Online Clearance Monitor. Operating instructions for 4008 H7S Dialysis Machines, Fresenius Medical Care 2000.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Fridolin, I., Jerotskaja, J., Lauri, K., Scherbakov, A., Luman, M. (2007). Accurate On-line Estimation of Delivered Dialysis Dose by Dialysis Adequacy Monitor (DIAMON). In: Jarm, T., Kramar, P., Zupanic, A. (eds) 11th Mediterranean Conference on Medical and Biomedical Engineering and Computing 2007. IFMBE Proceedings, vol 16. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73044-6_89
Download citation
DOI: https://doi.org/10.1007/978-3-540-73044-6_89
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-73043-9
Online ISBN: 978-3-540-73044-6
eBook Packages: EngineeringEngineering (R0)