Skip to main content

One Year of Experience with Remote Quality Assurance of Digital Mammography Systems in the Flemish Breast Cancer Screening Program

  • Conference paper
Digital Mammography (IWDM 2008)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Included in the following conference series:

Abstract

The European Guidelines on Digital Mammography (EUREF) prescribe that regularly the homogeneity of the used digital systems should be tested. In a decentralized screening environment with centralized quality control (QC) supervision this can become a time consuming work. Therefore we developed a novel method to simplify remote QC. Exposures of a homogeneous plate of PMMA are made daily under clinical conditions and are sent to our locally installed analysis software. Several parameters are calculated for the complete image, for 6 reference regions of interest (ROIs) and for series of small adjacent ROIs all over the image. These calculated parameters are summarized in maps that are treated as thumbnail images. Analysis results are sent to the reference site where they are supervised by a trained physicist and compared with the results of previous tests. Several artifacts could be traced with the thumbnail images. These include: dirt on phosphor cassettes, scanline artifacts, scratches on the IP and burned-in markers for CR units. For DR units, increasing ghost image factors, lag images, crystallization of detector material, defective pixel artifacts and several electrical artifacts were noticed. Our initial experience indicates that failures with digital mammography devices can be traced remotely via thumbnail images of the above parameters that are electronically sent to our reference center, instead of the full-size image.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Thierens, H., Bosmans, H., Buls, N., Bacher, K., De Hauwere, A., Jacobs, J., Clerinx, P.: Typetesting of the physical characteristics of digital mammography systems for screening within the Flemish breast cancer screening programme. Eur. J. Radiol. (2007)

    Google Scholar 

  2. van Engen, R., et al.: The European protocol for the quality control of the physical and technical aspects of mammography screening. Part B. In: European Guidelines for Breast Cancer Screening, 4th edn. (2006)

    Google Scholar 

  3. Jacobs, J., Deprez, T., Marchal, G., Bosmans, H.: The Automatic Analysis of Digital Images for Quality Control Purposes Made Easy with a Generic Extendable and Scriptable DICOM Router. In: Proceedings of the Scientific Assembly and Annual Meeting of the Radiological Society of North America, Chicago, IL (December 2006)

    Google Scholar 

  4. Van Engen, R.E., Swinkels, M.M.J., Oostveen, L.J., Geertse, T.D., Visser, R.: Using a Homogeneity Test as Weekly Quality Control on Digital Mammography Units. In: Proceedings of the 8th International Workshop on Digital Mammography, Manchester, United Kingdom, pp. 259–265 (2006)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Jacobs, J., Lemmens, K., Nens, J., Michielsen, K., Marchal, G., Bosmans, H. (2008). One Year of Experience with Remote Quality Assurance of Digital Mammography Systems in the Flemish Breast Cancer Screening Program. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_97

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_97

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics