Skip to main content

Validation of a Digital Mammography Image Simulation Chain with Automated Scoring of CDMAM Images

  • Conference paper
Digital Mammography (IWDM 2008)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Included in the following conference series:

Abstract

A wide variety of digital mammography systems are available for breast cancer imaging, each varying in physical performance. However, the relationship between physical performance assessment and clinical outcome is not clear. Thus, a means of simulating technically and clinically realistic images from different systems would represent a first step towards elucidating the impact of physical performance on clinical outcome. To this end, a framework for simulating technically realistic images has been developed. A range of simulated test objects, including CDMAM have been used to determine whether the simulation chain correctly reproduces these objects thus validating the simulation framework. Results evaluated for two digital mammography systems have been promising, with simulated images proving similar to experimental images for Modulation Transfer Function and Normalised Noise Power Spectrum measurements differing by approximately 3%.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Young, K.C., Cook, J.J.H., Oduko, J.M.: Automated and human determination of threshold contrast for digital mammography systems. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. LNCS, vol. 4046, pp. 266–272. Springer, Heidelberg (2006)

    Chapter  Google Scholar 

  2. Visser, M., Karssemeijer, N.: Manual CDCOM version 1.5: software for automated readout of CDMAM 3.4 images, http://www.euref.org

  3. Young, K.C., Cook, J.J.H., Oduko, J.M., Bosmans, H.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: Flynn, M.J., Hsieh, J. (eds.) Medical Imaging 2006: Physics of Medical Imaging, vol. 6142. SPIE, San Diego (2006)

    Google Scholar 

  4. Young, K.C., Alsager, A., Oduko, J.M., Bosmans, H., Verbrugge, B., Geertse, T., van Engen, R.: Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems. In: Hsieh, J., Samei, E. (eds.) Medical Imaging 2008: Physics of Medical Imaging, vol. 6913. SPIE (2008)

    Google Scholar 

  5. Saunders, R.S., Samei, E.: A method for modifying the image quality parameters of digital radiographic images. Medical Physics 30(11), 3006–3017 (2003)

    Article  Google Scholar 

  6. Sandborg, M., Dance, D.R., Alm Carlsson, G.: Calculation of contrast and signal-to-noise degradation factors for digital detectors in chest and breast imaging. Department of Radiation Physics, Linkoping University (2003) ISSN 1102-1799

    Google Scholar 

  7. Marshall, N.W.: A comparison between objective and subjective image quality measurements for a full field digital mammography system. Phys. Med. Biol. 51, 2441–2463 (2006)

    Article  Google Scholar 

  8. Carton, A.-K., Vandenbroucke, D., Struye, L., Maidment, A.D.A., Kao, Y.-H., Albert, M., Bosmans, H., Marchal, G.: Validation of MTF measurement for digital mammography quality control. Medical Physics 32(6), 1684–1695 (2005)

    Article  Google Scholar 

  9. Karssemeijer, N., Thijssen, M.A.O.: Determination of contrast detail curves of mammography systems by automated image analysis. In: Doi, K., Giger, M.L., Nishikawa, R.M., Schmidt, R.A. (eds.) IWDM 1996, pp. 155–160. Elsevier, Amsterdam (1996)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Yip, M., Alsager, A., Lewis, E., Wells, K., Young, K.C. (2008). Validation of a Digital Mammography Image Simulation Chain with Automated Scoring of CDMAM Images. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_57

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_57

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics