Zibari G, Rohr M, Landreneau M, Bridges R, DeVault G, Petty F, Costley K, Brown S, McDonald J: Complications from permanent hemodialysis vascular access Surgery 1988; 104: 681–686
Vorwerk D, Günther RW, Schürmann K, Sohn M: Perkutane Behandlungsmöglichkeiten beim thrombotischen Verschluss von Brescia-Cimino-Dialyseshunt. Fortschr Röntgenstr 1995, 162: 236–240
Kistler D, Bohndorf K, Günther RW. Kombiniert chirurgischradiologisches Vorgehen beim Verschluss eines Hämodialyseshunts. Chirurg 1990; 61: 84–86
Smith T, Hunter D, Darcy M, Castaneda-Zuniga W, Amplatz K: Thrombosed synthetic hemodialysis access fistulas: the success of combined thrombectomy and angioplasty (Technical note). Am J Roentgenol 1986; 147: 161–163
Raynaud A, Auguste M, Pagny J, Beyssen B, Bourquelot P: Acute angioaccess thrombosis. treatment by fibrinolysis associated to thromboaspiration. Abstract 138, p 79 Angioaccess for Hemodialysis, Tours 1996
Valji K, Bookstein J, Roberts A, Davis G: Pharmacomechanical thrombolysis and angioplasty in the management of clotted haemodialysis grafts: early and late clinical results. Radiology 1991; 178: 243–248
Davis G, Dowd C, Bookstein J, Maroney T, Lang E, Halasz N: Thrombosed dialysis grafts. Efficacy of intrathrombic deposition of concentrated urokinase, clot maceration and angioplasty Am J Roentgenol 1987; 149: 177–181
Poulain F, Raynaud A, Bourquelot P, Knight C, Rovani X, Gaux J: Local thrombolysis and thromboaspiration in the treatment of acutely thrombosed arteriovenous hemodialysis fistulas. Cardiovasc Intervent Radiol 1991; 14: 98–101
Young A, Hunter D, Castaneda-Zuniga W, So S, Mercado S, Cardella J, Amplatz K: Thrombosed synthetic hemodialysis access fistulas: failure of fibrinolytic therapy. Radiology 1985; 154: 639–642
Beathard G: Mechanical versus pharmacomechanical thrombolysis for the treatment of thrombosed dialysis access grafts. Kidney Int 1994; 45: 1401–1406
Haage P, Vorwerk D, Wildberger JE, Piroth W, Schurmann K, Gunther RW: Percutaneous treatment of thrombosed primary arteriovenous hemodialysis access fistulae. Kidney Int 2000; 57: 1169–1175
Vorwerk D, Sohn M, Schurmann K, Hoogeveen Y, Gladziwa U, Guenther RW: Hydrodynamic thrombectomy of hemodialysis fistulas: first clinical results. J Vasc Intervent Radiol 1994; 5: 813–821
Turmel-Rodrigues L, Pengloan J, Baudin S, Testou D, Abaza M, Dahdah G, Mouton A, Blanchard D: Treatment of stenosis and thrombosis in haemodialysis fistulas and grafts by interventional radiology. Nephrol Dial Transplant 2000; 15: 2029–2036
Turmel-Rodrigues L, Pengloan J, Rodrigue H, Brillet G, Lataste A, Pierre D, Jourdan JL, Blanchard D: Treatment of failed native arteriovenous fistulae for hemodialysis by interventional radiology. Kidney Int 2000; 57: 1124–1140
Vorwerk D, Schürmann K, Müller-Leisse C, Adam G, Bücker A, Sohn M, Kierdorf H, Günther RW: Hydrodynamic thrombectomy of haemodialysis grafts and fistulas: results of 51 procedures. Nephrol Dialys Transplant 1996; 11: 1058–1064
Hathaway PB, Vesely TM: The apex-puncture technique for mechanical thrombolysis of loop hemodialysis grafts. J Vasc Interv Radiol 1999; 10: 775–779
Barth KH, Gosnell MR, Palestrant AM, Martin LG, Siegel JB, Matalon TA, Goodwin SC, Neese PA, Swan TL, Uflacker R: Hydrodynamic thrombectomy system versus pulse-spray thrombolysis for thrombosed hemodialysis grafts: a multicenter prospective randomized comparison. Radiology 2000; 217: 678–684
Vesely TM, Williams D, Weiss M, Hicks M, Stainken B, Matalon T, Dolmatch B: Comparison of the angiojet rheolytic catheter to surgical thrombectomy for the treatment of thrombosed hemodialysis grafts. Peripheral AngioJet Clinical Trial. J Vasc Interv Radiol 1999; 10: 1195–1205
Uflacker R, Rajagopalan PR, Selby JB, Hannegan C: Investigators of the Clinical Trial Sponsored by Microvena Corporation. Thrombosed dialysis access grafts: randomized comparison of the Amplatz thrombectomy device and surgical thromboembolectomy. Eur Radiol 2004; 14: 2009–2014. Epub
Lazzaro CR, Trerotola SO, Shah H, Namyslowski J, Moresco K, Patel N: Modified use of the arrow-trerotola percutaneous thrombolytic device for the treatment of thrombosed hemodialysis access grafts. J Vasc Interv Radiol 1999; 10: 1025–1031
Rocek M, Peregrin JH, Lasovickova J, Krajickova D, Slaviokova M: Mechanical thrombolysis of thrombosed hemodialysis native fistulas with use of the Arrow-Trerotola percutaneous thrombolytic device: our preliminary experience. J Vasc Interv Radiol 2000; 11: 1153–1158
Trerotola S, Lund G, Scheel P, Savader S, Venbrux A, Osterman F: Thrombosed dialysis access grafts: percutaneous mechanical declotting without urokinase. Radiology 1994; 191: 721–726
Swan TL, Smyth SH, Ruffenach SJ, Berman SS, Pond GD: Pulmonary embolism following hemodialysis access thrombolysis/thrombectomy. J Vasc Interv Radiol 1995; 6: 683–686
Harp RJ, Stavropoulos SW, Wasserstein AG, Clark TW: Pulmonary hypertension among end-stage renal failure patients following hemodialysis access thrombectomy. Cardiovasc Intervent Radiol 2005; 28: 17–22
Vorwerk D, Guenther RW, Schurmann K: Stent placement on fresh venous thrombosis. Cardiovasc Intervent Radiol 1997; 20: 359–363
Schwab S, Raymond J, Saeed M, Newman G, Dennis P, Bollinger R: Prevention of hemodialysis fistula thrombosis. Early detection of venous stenoses. Kidney Int 1989; 36: 707–711
Palder S, Kirkman R, Whittemore A, Hakim R, Lazarus M, Tilney N: Vascular access for hemodialysis. Patency rates and results of revision. Ann Surg 1985; 202: 235–239
Smith T, Hunter D, Darcy M, Castaneda-Zuniga W, Amplatz K: Thrombosed synthetic hemodialysis access fistulas: the success of combined thrombectomy and angioplasty (Technical note). Am J Roentgenol 1986; 147: 161–163
Etheredge E, Haid S, Maeser M, Sicard G, Anderson C. Salvage operations for malfunctioning PTFE hemodialysis access grafts. Surgery 1983; 94: 464–470
Brotman D, Fandos L, Faust G, Doscher W, Cohen J. Hemodialysis graft salvage. J Am Coll Surg 1994; 178: 431–434
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Vorwerk, D. (2007). Management of Occluded Hemodialysis Shunts, Grafts, and Venous Access. In: Marincek, B., Dondelinger, R.F. (eds) Emergency Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-68908-9_29
Download citation
DOI: https://doi.org/10.1007/978-3-540-68908-9_29
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-26227-5
Online ISBN: 978-3-540-68908-9
eBook Packages: MedicineMedicine (R0)