Skip to main content

Gray Scale Registration of Mammograms Using a Model of Image Acquisition

  • Conference paper

Part of the book series: Lecture Notes in Computer Science ((LNCS,volume 2732))

Abstract

A parametric technique is proposed to match the pixel-value distributions of two mammograms of the same woman. It can be applied to mammograms of the left and the right breast, or, more effectively, to temporal mammograms, e.g., from two screening rounds. The main reason to match mammograms is to lessen irrelevant differences between images due to acquisition: by varying breast compression, different film types, et cetera. Firstly, a technique like this might reduce the radiologist’s efforts to detect relevant differences like abnormal growth in breast tissue that signals breast cancer. Secondly, though not the aim of this study, applications might be found in subtraction radiology or in the computer aided detection of abnormalities in temporal mammograms. Instead of arbitrarily shifting and/or scaling the pixel-values of one image to match the other or directly mapping one histogram to the other, the proposed method is based on general aspects of acquisition. This encompasses (1) breast compression; (2) exposure time; (3) incident radiation intensity; and, (4a) film properties and digitization for screen-film mammograms, or (4b) detector response for unprocessed digital mammograms. The method does not require a priori knowledge about specific settings of acquisition to match histograms; the degrees of freedom are estimated from the pixel-value distributions of the two mammograms themselves. By the method it is possible to match digitized screen-film mammograms (in the next also referred to as analog mammograms) as well as unprocessed digital mammograms in any of the four possible combinations: analog to analog, analog to digital, digital to analog, and digital to digital.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Sallam, M.Y., Bowyer, K.W.: Registration and difference analysis of corresponding mammogram images. Medical Image Analysis 3(2), 103–118 (1999)

    Article  Google Scholar 

  2. Wirth, M.A., Narhan, J., Gray, D.: Non-rigid mammogram registration using mutual information. In: Proc. SPIE Medical Imaging 2002: Image Processing, vol. 4684, pp. 562–573 (2002)

    Google Scholar 

  3. Thurfjell, M.G., Vitak, B., Azavedo, E., Svane, G., Thurfjell, E.: Effect on sensitivity and specificity of mammography screening with or without comparison of old mammograms. ACTA Radiologica 41(1), 52–56 (2000)

    Article  Google Scholar 

  4. Burnside, E.S., Sickles, E.A., Sohlich, R.E., Dee, K.E.: Differential value of comparison with previous examinations in diagnostic versus screening mammography. American Journal of Roentgenology 179(5), 1173–1177 (2002)

    Google Scholar 

  5. Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., Suetens, P.: Multimodality image registration by maximisation of mutual information. IEEE Transactions on Medical Imaging 16(2), 187–198 (1997)

    Article  Google Scholar 

  6. Barrett, H.H., Swindell, W.: Radiological Imaging: the Theory of Image Formation, Detection, and Processing, vol. I and II. Academic Press, Inc., London (1981)

    Google Scholar 

  7. Hurter, F., Driffield, V.C.: Photo-chemical investigations and a new method of the sensitiveness of photographic plates. The Journal of the Society of Chemical Industry, 455–469 (1890)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2003 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Snoeren, P.R., Karssemeijer, N. (2003). Gray Scale Registration of Mammograms Using a Model of Image Acquisition. In: Taylor, C., Noble, J.A. (eds) Information Processing in Medical Imaging. IPMI 2003. Lecture Notes in Computer Science, vol 2732. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-45087-0_34

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-45087-0_34

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-40560-3

  • Online ISBN: 978-3-540-45087-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics