Abstract
Aim
The alteration of an already existing voxel model, after the completion of its segmentation, is a complicated process, leading to many problems to be solved. To solve those intricacies in an easy way, a new software tool was developed and shall be presented here.
In the voxel model, organs are represented by voxels (3d-pixels). If the organs are modified, no bit of tissue, i.e. voxel, may vanish nor an extra one should appear. That means organs cannot be modified without considering the neighbouring tissue. Thus, the principle of organ modification is based on the reassignment of voxels from one organ/tissue to another; deleting and adding voxels is only possible at the external surface, i.e. skin. The modifications are done by semiautomatic routines but including human control. Because of the complexity of the matter, a person has to validate that the applied changes on organs are still anatomically reasonable. A graphical user interface was designed to fulfil the purpose of a comfortable working process and an adequate graphical display of the modified voxel model was developed.
With the presented tool, called “VolumeChange”, two human models were adjusted to fit the reference organ masses of a male and a female adult, as defined by the International Commission on Radiological Protection (ICRP). These two new voxel models of the adult male and female reference person are going to succeed the MIRD-type models, which have been used for dosimetry purposes until now.
Single organs, organ complexes and even whole limbs can be edited with respect to volume, shape and location. The new software tool cannot only be used to adjust a voxel model to reference organ masses but also to fit individual patient characteristics. This introduces an important step towards individual patient dosimetry.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Fisher H L, Snyder W S (1967), Distribution of dose in the body from a source of gamma rays distributed uniformly in an organ, Oak Ridge National Laboratory, ORNL-4168, Oak Ridge, TN
Zankl M, Wittmann A (2001) The adult male voxel model “Golem” segmented from whole body CT patient data. Radiat. Environ. Biophys. 153–162
Dimbylow P J (1996) The development of realistic voxel phantoms for electromagnetic field dosimetry, Workshop on Voxel Phantom Development, Chilton, UK, pp 1–7
International Commission on Radiological Protection (1975), Reference man: Anatomical, physiological and metabolic characteristics, Pergamon Press, 23, Oxford, UK
Kramer R, Vieira J W, Khoury H J, et al. (2003) All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry. Phys. Med. Biol. 1239–1262
Kramer R, Khoury H J, Vieira J W, et al. (2004) All about FAX: a female adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry. Phys. Med. Biol. 5203–5216
Dimbylow P (2005) Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields. Phys. Med. Biol. 1047–1070
International Commission on Radiological Protection (2002), Basic anatomical and physiological data for use in radiological protection: reference values, Pergamon Press, 89, Oxford, UK
Lee C T, Lee J (2004) The Korean adult male voxel model “Korman” segmented form magnetic resonance images. Med. Phys. 1017–1022
Nagaoka T, Watanabe S, Sakurai K, et al. (2004) Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry. Phys. Med. Biol. 1–15
Zankl M, Becker J, Fill U, et al. (2005) GSF male and female adult voxel models representing ICRP reference man-the present status, The Monte Carlo Method: Versatility Unbounded in a Dynamic Computing World, Chatttanooga, 17–21 April 2005, pp
Petoussi-Henss N, Zankl M, Fill U, et al. (2002) The GSF family of voxel phantoms. Phys. Med. Biol. 89–106
Author information
Authors and Affiliations
Corresponding author
Editor information
Rights and permissions
Copyright information
© 2007 International Federation for Medical and Biological Engineering
About this paper
Cite this paper
Becker, J., Zankl, M., Petoussi-Henss, N. (2007). Modifications of human voxel models used for radiation protection calculations. In: Magjarevic, R., Nagel, J.H. (eds) World Congress on Medical Physics and Biomedical Engineering 2006. IFMBE Proceedings, vol 14. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-36841-0_525
Download citation
DOI: https://doi.org/10.1007/978-3-540-36841-0_525
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-36839-7
Online ISBN: 978-3-540-36841-0
eBook Packages: EngineeringEngineering (R0)