Abstract
There are different stereotactic systems with different tables for breast biopsy available around the world. In three of the six described methods or tables, the patients are in the prone position, whereas the other techniques use the upright system. The Giotto system: the Mammobed in combination with a digital mammography unit The MultiCare Platinum system: the Lorad table from Hologic The Fischer table Breast biopsy with upright stereotactic image guidance by Siemens The GE system: Diamond with Delta 32 The StereoLoc II system from Hologic
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Kochli OR (2000) Developments in minimally invasive breast surgery – overview and our own experience: new diagnostic and therapeutic challenges in breast cancer. Gynakol Geburtshilfliche Rundsch 40:3–12
Lifrange E, Dondelinger RF, Quatresooz P, Vandevorst G, Colin C (2002) Stereotactic breast biopsy with an 8-gauge, directional, vacuum-assisted probe: initial experience. Eur Radiol:2180–2187
Marti WR, Zuber M, Oertli D, Weber WP, Muller D, Kochli OR, Langer I, Harder F (2001) Advanced breast biopsy instrumentation for the evaluation of impalpable lesions: a reliable diagnostic tool with little therapeutic potential. Eur J Surg 167:15–18
Meloni GB, Becchere MP, Soro D, Feo CF, Profili S, Dettori G, Trignano M, Navara G, Canalis GC (2002) Percutaneous vacuum-assisted core breast biopsy with upright stereotactic equipment. Indications, limitations and results. Acta Radiol 43:575–578
Senn Bahls, E, Dupont Lampert V, Oelschlegel C, Senn HJ (2006) Multitarget stereotactic core-needle breast biopsy (MSBB) – an effective and safe diagnostic intervention for non-palpable breast lesions: A large prospective single institution study. Breast 17:222–229
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Köchli, O.R. (2009). Available Stereotactic Systems for Breast Biopsy. In: Brun del Re, R. (eds) Minimally Invasive Breast Biopsies. Recent Results in Cancer Research, vol 173. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-31611-4_5
Download citation
DOI: https://doi.org/10.1007/978-3-540-31611-4_5
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-31403-5
Online ISBN: 978-3-540-31611-4
eBook Packages: MedicineMedicine (R0)