With image-guided percutaneous needle biopsy, different procedures are available today to remove tissue samples without surgery. By guiding tissue removal stereotactically with X-ray, ultrasound, or magnetic resonance imaging (MRI), even nonpalpable lesions can be accurately biopsied. None of these methods requires hospitalization and all of them can be carried out with the patient under local anesthesia. Which method is used in an individual case depends on the type of lesion detected.
There are acknowledged guidelines regarding indications and technique for the different procedures as well various treatises on the efficacy and effectiveness of minimally invasive breast biopsies.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Agence d’évaluation des technologies et des modes d’intervention en santé (AETMIS) (2006) Macrobiopsie mammaire par aspiration. Note technique préparée par Wilber Deck (AETMIS 06-06). AETMIS, Montréal, xi-38, p 55
Ambrogetti D, Bianchi S, Ciatto S (2003) Accuracy of percutaneous core biopsy of isolated breast microcalcifications identified by mammography. Experience with a vacuum-assisted large-core biopsy device. Radiol Med (Torino) 106(4):313–319
Apesteguia L, Mellado M, Saenz J, Cordero JL, Reparaz B, De Miguel C (2002) Vacuum-assisted breast biopsy on digital stereotaxic table of nonpalpable lesions non-recognisable by ultrasonography. Eur Radiol 12(3):638–645
Barreau B, Tastet S, Lakdja F, Henriquès C, Valentin F, Labat MJ, Dilhuydy MH (2005) Le don d’information dans les prélèvements percutanés mammaires: savoir le dire, savoir le faire. Bulletin du Cancer 92(3):257–265
Beck RM, Götz L, Heywang-Köbrunner SH (2000) Stereotaxic vacuum core breast biopsy: Experience of 560 patients. Swiss Surg 6(3):108–110
Brenner RJ, Bassett LW, Fajardo LL, Dershaw DD, Evans WP, Hunt R, Lee C, Tocino I, Fisher P, McCombs M, Jackson VP, Feig SA, Mendelson EB, Margolin FR, Bird R, Sayre J (2001) Stereotactic core-needle breast biopsy: a multi-institutional prospective trial. Radiology 218(3):866–872
Brun del Re R and Study Group “Evaluation bidgesteuerter minimal-invasiver Mammaeingriffe” (2007) [Gesuch um Evaluationsentlassung der bildgesteuerten minimal-invasiven Mammaeingriffe] Final Report on minimal invasive breast biopsies 2002-2006. On behalf of the Swiss Federal Office of Public Health (Members of the Study Group see chapter 11)
Buchberger W, Niehoff A, Obrist P, Rettl G, Dunser M (2002) Ultraschallgezielte Stanzbiopsie der Mamma: Technik, Ergebnisse, Indikationen. [Sonographically guided core needle biopsy of the breast: technique, accuracy and indications] Radiologe 42(1):25–32
Burbank F (1997) Stereotactic breast biopsy: comparison of 14- and 11-gauge mammotome probe performance and complication rates. Am Surg 63(11):988–995
Burbank F, Parker SH (1998) Methods for evaluating the quality of an image-guided breast biopsy program. Semin Breast Dis 1(2):71–83. Reproduced From Lai et al., Can Assoc Radiol J 2001;52(4):223-227
Burns RP, Brown JP, Roe SM, Sprouse LR 2nd, Yancey AE, Witherspoon LE (2000) Stereotactic core-needle breast biopsy by surgeons: minimum 2-year follow-up of benign lesions. Ann Surg 232(4):542–548
Cangiarella J, Waisman J, Cohen JM, Chhieng D, Symmans WF, Axelrod D, Gross J (2001) Radial sclerosing lesion: correlation between mammotome core biopsy and surgical excision. Breast J 7(1):66–67
Cassano E, Urban L, Pizzamiglio M, Abbate F, Maisonneuve P, Renne G, Viale G, Bellomi M (2007) Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 102:103–110
Cho N, Moon WK, Cha JH, Kim SM, Kim SJ, Lee SH, Chung HK, Cho KS, Park IA, Noh DY (2005) Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods. Korean J Radiol 6(2):102–109
Ciatto S, Houssami N, Ambrogetti D, Bianchi S, Bonardi R, Brancato B, Catarzi S, Risso GG (2007) Accuracy and underestimation of malignancy of breast core needle biopsy: the Florence experience of over 4000 consecutive biopsies. Breast Cancer Res Treat 101(3):291–297
Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S (2005) Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound 33(2):47–52
Dahlstrom JE, Jain S (2001) Histological correlation of mammographically detected microcalcifications in stereotactic core biopsies. J Pathol 33(4):444–448
de Waal JC, Prechtel K, Weitz J, Staufer F, Pankratz-Hauer M, Nerlich A (2006) [Scope and limitations of diagnostics in breast disease-focussing on large core biopsy] Möglichkeiten und Grenzen der Mammadiagnostik unter besonderer Berucksichtigung der perkutanen Stanzbiopsie. UltraschallMed-27(5)
Diebold T, Jacobi V, Krapfl E, von Minckwitz G, Solbach C, Ballenberger S, Hochmuth K, Balzer JO, Fellbaum M, Kaufmann M, Vogl TJ (2003) [The role of stereotactic 11G vacuum biopsy for clarification of BI- RADS IV findings in mammography] Wertigkeit der stereotaktischen 11 G-Vakuumbiopsie zur Abklarung von Befunden der Kategorie BI-RADS IV in der Mammographie. Rofo 175(4):489–494
Dillon MF, Hill ADK, Quinn CM, O’Doherty A, McDermott EW, O’Higgins N (2005) The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases Ann Surg 242(5):701–707
Fajardo LL, Pisano ED, Caudry DJ, Gatsonis CA, Berg WA, Connolly J, Schnitt S, Page DL, McNeil BJ (2004) Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study. Acad Radiol 11(3):293–308
Fehr MK, Hornung R, Von Orelli S, Haller U (2002) [Stereotaxic breast biopsy techniques have become the standard of care for mammographically suspicious lesions] Gynakol Geburtshilfliche Rundsch 42(4):201–211
Golub RM, Bennett CL, Stinson T, Venta L, Morrow M (2004) Cost minimization study of image-guided core biopsy versus surgical excisional biopsy for women with abnormal mammograms. J Clin Oncol 22(12):2430–2437
Han BK, Choe YH, Ko YH, Nam SJ, Kim JH, Yang JH (2003) Stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up. Kor J Radiol 4(4):217–223
Heywang-Kobrunner SH, Schaumloffel U, Viehweg P, Hofer H, Buchmann J, Lampe D (1998) Minimally invasive stereotaxic vacuum core breast biopsy. Eur Radiol 8(3):377–385
Higgins JPT, Green S (eds) (2005) Cochrane handbook for systematic reviews of interventions 4.2.5 [updated May 2005]. In: The Cochrane Library, Issue 3. Wiley, Chichester, UK
Hoorntje LE, Peeters PH, Mali WP, Borel Rinkes IH (2003) Vacuum-assisted breast biopsy: a critical review. Eur J Cancer 39(12):1676–1683
Houssami N, Ciatto S, Ellis I, Ambrogetti D (2007) Underestimation of malignancy of breast core-needle biopsy: concepts and precise overall and category-specific estimates. Cancer 109(3):487–495
Huber S, Wagner M, Medl M, Czembirek H (2003) Benign breast lesions: minimally invasive vacuum-assisted biopsy with 11-gauge needles patient acceptance and effect on follow-up imaging findings. Radiology 226(3):783–790
Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni FA, Finkelstein SI, Shepard MJ (1999) Breast imaging: stereotactic, Automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 210:799–805
Kaelin CM, Smith TJ, Homer MJ, Taback B, Azurin D, Schmid CH, Weld L (1995) Safety, accuracy, and diagnostic yield of needle localization biopsy of the breast performed using local anesthesia.J Am Coll Surg 180(4):509–510
Kettritz U, Morack G, Decker T (2005) Stereotactic, vacuum-assisted breast biopsies in 500 women with microcalcifications: radiological and pathological correlations. Eur J Radiol 55(2):270–6
Kirkwood BR (1988) Further methods for contingency tables (Chapter XIV) in essentials of medical statistics. Blackwell Scientific, London, pp 102–104
Kirshenbaum KJ, Voruganti T, Overbeeke C, Kirshenbaum MD, Patel P, Kaplan G, Maker V, August C, Cavallino RP (2003) Stereotactic core needle biopsy of nonpalpable breast lesions using a conventional mammography unit with an add-on device. AJR Am J Roentgenol 181(2):527–523
Klem D, Jacobs HK, Jorgensen R, Facenda LS, Baker DA, Altimari A (1999) Stereotactic breast biopsy in a community hospital setting. Am Surg 8:737–740
Koskela AK, Sudah M, Berg MH, Karja VJ, Mustonen PK, Kataja V, Vanninen RS (2005) Add-on device for stereotactic core-needle breast biopsy: how many biopsy specimens are needed for a reliable diagnosis? Radiology 236(3):801–809
Lai JT, Burrowes P, MacGregor JH (2001) Diagnostic accuracy of a stereotaxically guided vacuum-assisted large-core breast biopsy program in Canada. Can Assoc Radiol J 52(4):223–7
Lee CH, Philpotts LE, Horvath LJ (1999) Tocino I follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: frequency of mammographic change and false-negative rate. Radiology 212(1):189–194
Liberman L, Sama M (2000) Cost-effectiveness of stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR 175:53–58
Liberman L, Ernberg LA, Heerdt A, Zakowski MF, Morris EA, LaTrenta LR, Abramson AF, Dershaw DD (2000) Palpable breast masses: is there a role for percutaneous imaging-guided core biopsy? AJR Am J Roentgenol 175(3):779–787
Liberman L, Benton CL, Dershaw DD, Abramson AF, LaTrenta LR, Morris EA (2001) Learning curve for stereotactic breast biopsy: how many cases are enough? AJR 176:721–727
Lomoschitz FM, Helbich TH, Rudas M, Pfarl G, Linnau KF, Stadler A, Jackman RJ (2004) Stereotactic 11-gauge vacuum-assisted breast biopsy: influence of number of specimens on diagnostic accuracy. Radiology 232(3):897–903
Makoske T, Preletz R, Riley L, Fogarty K, Swank M, Cochrane P, Blisard D (2000) Long-term outcomes of stereotactic breast biopsies. Am Surg 66(12):1104–1108
Meloni GB, Dessole S, Becchere MP, Soro D, Capobianco G, Ambrosini G, Nardelli GB, Ca-nalis GC (2001) Ultrasound-guided mammotome vacuum biopsy for the diagnosis of impalpable breast lesions. Ultrasound Obstet Gynecol 18(5):520–4
Meyer JE, Smith DN, Lester SC, Kaelin C, DiPiro PJ, Denison CM, Christian RL, Harvey SC, Selland DG, Durfee SM (1999) Large-core needle biopsy of nonpalpable breast lesions. JAMA 281:1638–1641
Pfarl G, Helbich TH, Riedl CC, Wagner T, Gnant M, Rudas M, Liberman L (2002a) Stereotactic 11-gauge vacuum-assisted breast biopsy: a validation study. AJR Am J Roentgenol 179(6):1503–1507
Pfarl G, Helbich TH, Riedl CC, Rudas M, Wagner T, Memarsadeghi M, Lomoschitz F (2002b) Stereotaktische Nadelbiopsie der Brust: Diagnosesicherheit verschiedener Biopsie-Systeme und Nadelkaliber. (Stereotactic needle breast biopsy: diagnostic reliability of various biopsy systems and needle sizes). Fortschr Röntgenstr 174:614–619
Rappaport W,Thompson S, Wong R, Leong S, Villar H (1991) Complications associated with needle localization biopsy of the breast. Surg Gynecol Obstet 172(4):303–306
Reynolds HE (2000) Core needle biopsy of challenging benign breast conditions: a comprehensive literature review. Am J Roentgenol 174(5):1245–1250
Riedl CC, Pfarl G, Memarsadeghi M, Wagner T, Fitzal F, Rudas M, Helbich TH (2005) Lesion miss rates and false-negative rates for 1115 consecutive cases of stereotactically guided needle-localized open breast biopsy with long-term follow-up. Radiology 237(3):847–853
Sebag P, Tourasse C, Rouyer N, Lebas P, Denier JF, Michenet P (2006) [Value of vacuum assisted biopsies under sonography guidance: results from a multicentric study of 650 lesions] Place des macrobiopsies mammaires assistees par le vide sous guidage echographique: etude multi-centrique de 650 lesions. J Radiol 87(1):29–34
Siegmann KC, Wersebe A, Fischmann A, Fersis N, Vogel U, Claussen CD, Muller-Schimpfle M (2003) [Stereotactic vacuum-assisted breast biopsy - success, histologic accuracy, patient acceptance and optimizing the BI-RADS?-correlated indication] Stereotaktische Vakuumbiopsie mammographisch detektierter Lasionen - Erfolg, histologische Sicherheit, Patientenakzeptanz und BI-RADS trade mark -korrelierte Indikationsoptimierung. Rofo 175(1):99–104
Sittek H, Perlet C, Schneider P, Untch M, Kolopenko T, Reiser M (2002) [Stereotactic Vakuumbiopsie in der vornübergeneigten und sitzenden Position] Radiologe 42(1):19–24
Travade A, Isnard A, Bagard C, Bouchet F, Chouzet S, Gaillot A, Vilmant R (2002) [Stereotactic 11-gauge directional vacuum-assisted breast biopsy: experience with 249 patients] Macrobiopsies stereotaxiques par systeme a aspiration 11-G: a propos de 249 patientes. J Radiol 83(9-C1):1063–1071
Verkooijen HM, Peeters PH, Buskens E, Koot VC, Borel Rinkes IH, Mali WP, van Vroonhoven TJ (2000) Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis. Br J Cancer 82(5):1017–1021
Verkooijen HM, Buskens E, Peeters PH, Borel Rinkes IH, de Koning HJ, van Vroonhoven TJ (2002) Diagnosing non-palpable breast disease: short-term impact on quality of life of large-core needle biopsy versus open breast biopsy. Surg Oncol 10(4):177–181
Ward SE, Taves DH, McCurdy LI (2000) Stereotactic core needle biopsy of breast microcalcifications obtained using a standard mammography table with an add-on unit. Can Assoc Radiol J 51(1):10–15
Author information
Authors and Affiliations
Consortia
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Brun del Re, R., Bürki, R.E., Study Group MIBB of the Swiss Society of Senology. (2009). Systematic Review and Meta-analysis of Recent Data. In: Brun del Re, R. (eds) Minimally Invasive Breast Biopsies. Recent Results in Cancer Research, vol 173. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-31611-4_12
Download citation
DOI: https://doi.org/10.1007/978-3-540-31611-4_12
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-31403-5
Online ISBN: 978-3-540-31611-4
eBook Packages: MedicineMedicine (R0)