Abstract
Recent technical advances in electromagnetic (EM) tracking have facilitated the use of EM sensors in surgical interventions. Due to the susceptibility to distortions of the EM field when placed in close proximity to metallic objects, they require calibration in situ to maintain an acceptable degree of accuracy. In this paper, a freehand method is presented for calibrating electromagnetic position sensors by mapping the coordinate measurements to those from optical trackers. Unlike previous techniques, the proposed method allows for free movement of the calibration object, permitting C2 continuity and interdependence between positional and angular corrections. The proposed method involves calculation of a mapping from {ℝ3, SO(3)} to {ℝ3, SO(3)} with radial basis function interpolation based on a modified distance metric. The system provides efficient distortion correction of the EM field, and is applicable to clinical situations where a rapid calibration of EM tracking is required.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Solomon, S.B., White, P., Wiener, C.M., Orens, J.B., Wang, K.P.: Three dimensional ct-guided bronchoscopy with a real-time electromagnetic position sensor - a comparison of two image registration methods. Chest 118, 1783–1787 (2000)
Schwarz, Y., Mehta, A.C., Ernst, A., Herth, F., Engel, A., Besser, D., Becker, H.D.: Electromagnetic navigation during flexible bronchoscopy. Respiration 70, 516–522 (2003)
Mori, K., Deguchi, D., Sugiyama, J., Suenaga, Y., Toriwaki, J., Maurer, C.R., Takabatake, H., Natori, H.: Tracking of a bronchoscope using epipolar geometry analysis and intensity-based image registration of real and virtual endoscopic images. Med. Image Anal. 6, 321–336 (2002)
Shahidi, R., Bax, M.R., Maurer, C.R., Johnson, J.A., Wilkinson, E.P., Wang, B., West, J.B., Citardi, M.J., Manwaring, K.H., Khadem, R.: Implementation, calibration and accuracy testing of an imageenhanced endoscopy system. IEEE Trans. Med. Imaging 21, 1524–1535 (2002)
Kindratenko, V.: A survey of electromagnetic position tracker calibration techniques. Virtual Reality: Research, Development and Applications 5, 169–182 (2000)
Ikits, M., Brederson, J.D., Hansen, C., Hollerbach, J.: An improved calibration framework for electromagnetic tracking devices. In: Proc. IEEE Virtual Reality, pp. 63–70 (2000)
Livingston, M.A., State, A.: Magnetic tracker calibration for improved augmented reality registration. Presence-Teleoper. Virtual Env. 6, 532–546 (1997)
Birkfellner, W., Watzinger, F., Wanschitz, F., Ewers, R., Bergmann, H.: Calibration of tracking systems in a surgical environment. IEEE Trans. Med. Imaging 17, 737–742 (1998)
Nakada, K., Nakamoto, M., Sato, Y., Konishi, K., Hashizume, M., Tamura, S.: A rapid method for magnetic tracker calibration using a magneto-optic hybrid tracker. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2879, pp. 285–293. Springer, Heidelberg (2003)
Wu, X.H., Taylor, R.: A direction space interpolation technique for calibration of electromagnetic surgical navigation systems. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2879, pp. 215–222. Springer, Heidelberg (2003)
Frantz, D.D., Wiles, A.D., Leis, S.E., Kirsch, S.R.: Accuracy assessment protocols for electromagnetic tracking systems. Phys. Med. Biol. 2241–2251 (2003)
Kim, M.J., Kim, M.S., Shin, S.Y.: A general construction scheme for unit quaternion curves with simple high order derivatives. Computer Graphics 29, 369–376 (1995)
Kim, M.J., Kim, M.S., Shin, S.Y.: A compact differential formula for the first derivative of a unit quaternion curve. The Journal of Visualization and Computer Animation 7, 43–58 (1996)
Curtis, W.D., Janin, A.L., Zikan, K.: A note on averaging rotations. In: Virtual Reality. Annual International Symposium 1993, pp. 377–385 (1993)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2004 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Chung, A.J., Edwards, P.J., Deligianni, F., Yang, GZ. (2004). Freehand Cocalibration of Optical and Electromagnetic Trackers for Navigated Bronchoscopy. In: Yang, GZ., Jiang, TZ. (eds) Medical Imaging and Augmented Reality. MIAR 2004. Lecture Notes in Computer Science, vol 3150. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-28626-4_39
Download citation
DOI: https://doi.org/10.1007/978-3-540-28626-4_39
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-22877-6
Online ISBN: 978-3-540-28626-4
eBook Packages: Springer Book Archive