Modern medical devices are increasingly developed by composing a variety of interoperable elements such as medical devices, services, and platform infrastructures. In many scenarios, multi-vendor consortia are organized to support the development and deployment of interoperable medical systems, in which safety-critical element implementations, risk management results, and safety assurance are reused across organizational boundaries. This reality calls for an assurance case approach that supports interfacing, refinement, and composition of distributed, component-level claims and evidences to construct system-level assurance argumentation. We present a collection of objectives and top-level safety claims towards the development of such an approach for interoperable systems built using medical application platforms.

B. Larson—This work is sponsored in part by US National Science Foundation and Food and Drug Administration Scholar-in-Residence program (CNS 1238431,1355778,1446544,1565544).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 69.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 89.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. ASTM: F-2761: Medical devices and medical systems - essential safety requirements for equipment comprising the patient-centric integrated clinical environment (ICE) - Part 1: general requirements and conceptual model (2009)

    Google Scholar 

  2. Denney, E., Pai, G.: Towards a formal basis for modular safety cases. In: Koornneef, F., van Gulijk, C. (eds.) SAFECOMP 2015. LNCS, vol. 9337, pp. 328–343. Springer, Cham (2015). https://doi.org/10.1007/978-3-319-24255-2_24

    Chapter  Google Scholar 

  3. Gorski, J., Jarzebowicz, A., Miler, J.: Validation of services supporting healthcare standards conformance. Metrol. Meas. Syst. 19(2), 269–284 (2012)

    Article  Google Scholar 

  4. Hatcliff, J., et al.: Rationale and architecture principles for medical application platforms. In: Proceedings of the 2012 International Conference on Cyberphysical Systems, pp. 3–12 (2012)

    Google Scholar 

  5. Hawkins, R., Kelly, T., Habli, I.: Developing assurance cases for D-MILS systems. In: International Workshop on MILS: Architecture and Assurance for Secure Systems (2015)

    Google Scholar 

  6. ICE Alliance. http://www.icealliance.org

  7. Kelly, T.: Concepts and principles of compositional safety case construction. Contract Research Report for QinetiQ COMSA/2001/1/1 34 (2001)

    Google Scholar 

  8. Kelly, T.: Using software architecture techniques to support the modular certification of safety-critical systems. In: Proceedings of the 11th Australian Workshop on Safety Critical Systems and Software, vol. 69, pp. 53–65 (2006)

    Google Scholar 

  9. Kim, Y.J., Procter, S., Hatcliff, J., Ranganath, V.P., Robby: ecosphere principles for medical application platforms. In: IEEE International Conference on Healthcare Informatics (ICHI) (2015)

    Google Scholar 

  10. King, A., et al.: An open test bed for medical device integration and coordination. In: Proceedings of the 31st International Conference on Software Engineering, pp. 141–151 (2009). https://doi.org/10.1109/ICSE-COMPANION.2009.5070972

  11. MDPnP Program: OpenICE - open-source integrated clinical environment (2015). https://www.openice.info/

  12. Sljivo, I., Gallina, B., Carlson, J., Hansson, H.: Generation of safety case argument-fragments from safety contracts. In: Bondavalli, A., Di Giandomenico, F. (eds.) SAFECOMP 2014. LNCS, vol. 8666, pp. 170–185. Springer, Cham (2014). https://doi.org/10.1007/978-3-319-10506-2_12

    Chapter  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yi Zhang .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 This is a U.S. government work and its text is not subject to copyright protection in the United States; however, its text may be subject to foreign copyright protection

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Zhang, Y., Larson, B., Hatcliff, J. (2018). Assurance Case Considerations for Interoperable Medical Systems. In: Gallina, B., Skavhaug, A., Schoitsch, E., Bitsch, F. (eds) Computer Safety, Reliability, and Security. SAFECOMP 2018. Lecture Notes in Computer Science(), vol 11094. Springer, Cham. https://doi.org/10.1007/978-3-319-99229-7_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-99229-7_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-99228-0

  • Online ISBN: 978-3-319-99229-7

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics