Skip to main content

Researches on the Measurement of the Dissolved Oxygen Concentration in Stationary Waters

  • Conference paper
  • First Online:
Proceedings of the International Conference of Mechatronics and Cyber-MixMechatronics – 2018 (ICOMECYME 2018)

Abstract

The paper presents methods for measuring the dissolved oxygen concentration in water; the electrical method is presented by presenting an experimental installation designed and built in the laboratories of POLITEHNICA University in Bucharest. For the creation of fine air bubbles, a bubble generator with 0.1 mm orifices processed by spark-erosion was used. The results of the experimental researches on the measurement of dissolved oxygen in water are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Oprina, G., Pincovschi, I., Băran, G.: Hidro-Gazo-Dinamica Sistemelor de aerare echipate cu generatoare de bule. POLITEHNICA PRES, Bucureşti (2009)

    Google Scholar 

  2. Robescu, D., Robescu, D.L.: Procedee, instalaţii şi echipamente pentru epurarea apelor, Litografia UPB, Bucureşti (1996)

    Google Scholar 

  3. Droste, L.R.: Theory and Practice of Water and Wastewater Treatment. Wiley, New York (1996). ISBN 978-0-471-12444-3

    Google Scholar 

  4. Călușaru, I.: Influenţa proprietăţilor fizice ale lichidului asupra eficienţei proceselor de oxigenare, Teză de doctorat, Universitatea Politehnica din Bucureşti, Facultatea de Inginerie Mecanică și Mecatronică (2014)

    Google Scholar 

  5. Pătulea, A.S.: Influenţa parametrilor funcţionali şi a arhitecturii generatoarelor de bule fine asupra eficienţei instalaţiilor de aerare. Teză de doctorat, Universitatea Politehnica din Bucureşti (2012)

    Google Scholar 

  6. Oprina, G.: Contribuţii la hidro-gazo-dinamica difuzoarelor poroase, Teză de doctorat, Universitatea Politehnica din Bucureşti, Facultatea de Energetică (2007)

    Google Scholar 

  7. Robescu, D., Robescu, D.L., Verestoy, A.: Fiabilitatea proceselor, instalaţiilor şi echipamentelor de tratare şi epurare a apelor. Tehnică, Bucureşti (2002)

    Google Scholar 

  8. Robescu, D.L., Lanyi, S., Verestoy, A., Robescu, D.: Modelarea şi simularea proceselor de epurare. Tehnică Bucureşti (2004)

    Google Scholar 

  9. Băran, N., Patulea, A.S., Căluşaru, I.M.: The determination of the oxygen transfer speed in water in nonstationary conditions. In: International Proceedings of Computer Science and Information Technology, Mechanical Engineering, Robotics and Aerospace, pp. 267–272. IACSIT Press (2011). ISSN 2010-460X, ISBN 978-981-07-0420-9

    Google Scholar 

  10. Pătulea, A., Băran, N., Căluşaru, I.M.: Measurements of dissolved oxygen concentration in stationary water. World Environ. 2(4), 106–109 (2012)

    Google Scholar 

  11. Căluşaru, I.M., Costache, A., Băran, N., Ionescu, G.L., Donţu, O.: The determination of dissolved oxygen concentration in stationary water. Appl. Mech. Mater. 436, 233–237 (2012). (Trans Tech Publications, Switzerland)

    Article  Google Scholar 

  12. Pincovschi, I.: Hidrodinamica sistemelor disperse gaz-lichid, Teză de doctorat, Universitatea Politehnica din Bucureşti (1999)

    Google Scholar 

  13. Mitchel, T.O.: Luminescence based measurement of dissolved oxygen in natural waters (2006). www.hachenvironmental.com

  14. Noninvasive, D.O.: Measurement http://www.nomacerc.com/enology/nomasense_02_p300

  15. Căluşaru, I., Băran, N., Pătulea, A.: The influence of the constructive solution of fine bubble generators on the concentration of oxygen dissolved in water. Adv. Mater. Res. 538–541, 2304–2310 (2012). (Trans Tech Publications, Switzerland)

    Article  Google Scholar 

  16. Pătulea, A., Căluşaru, I.M., Băran, N.: Researches regarding the measurements of the dissolved concentration in water. Adv. Mater. Res. 550–553, 3388–3394 (2012). (Trans Tech Publications, Switzerland)

    Article  Google Scholar 

  17. Căluşaru-Constantin, M., Tănase, E.B., Băran, N., Mlisan-Cusma, Rasha: Researches regarding the modification of dissolved oxygen concentration in water. IJISET - Int. J. Innov. Sci. Eng. Technol. 1(6), 228–231 (2014)

    Google Scholar 

  18. Constantin, M., Băran, N., Tănase, B.: A new solution for water oxygenation. Int. J. Innov. Res. Adv. Eng. (IJIRAE) 2(7), 49–52 (2015)

    Google Scholar 

  19. Dobrovicescu, A., Băran, N., Chisacof, A.: Bazele termodinamici Tehnice, Elemente de Termodinamică Tehnică. POLITEHNICA PRESS (2009)

    Google Scholar 

  20. Băran, Gh., Pincovschi, I., Oprina, G., Bunea, F.: Performanţe ale generatoarelor de bule fine. Revista Hidrotehnica, București 53(3–4), 27–32 (2008)

    Google Scholar 

  21. Tănase, B., Besnea, D., Mlisan, R., Constantin, M., Băran, N.: Constructive solutions for the achievement of fine bubble generators based on micro-drilling technologies. IJISET - Int. J. Innov. Sci. Eng. Technol. 2(2), 46–50 (2015)

    Google Scholar 

  22. Tănase, E.B., Băran, N., Mlisan, R.: An efficient solution for water oxygenation. Asian Eng. Rev. 1(3), 36–40 (2014)

    Google Scholar 

  23. Căluşaru, I.M., Băran, N., Pătulea, A.: The influence of the constructive solution of fine bubble generators on the concentration of oxygen dissolved in water. Adv. Mater. Res. 538–541, 2304–2310 (2012). (Trans Tech Publications, Switzerland)

    Article  Google Scholar 

  24. Căluşaru, I.M., Băran, N., Pătulea, A.: Researches regarding the transfer of oxygen in water. In: The 3rd International Conference on Mechanic Automation and Control Engineering (MACE 2012), pp. 2617–2620 (2012). July 27th–29th, published by IEEE Computer Society CPS, and then submitted to be indexed by Ei Compendex, Baotou, China

    Google Scholar 

Download references

Acknowledgements

This work was supported by a grant of the Romanian National Authority for Scientific Research and Innovation, CCCDI – UEFISCDI, project number Manunet – MNET17/ENER2307 – CEBIOTREAT, within PNCDI III.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Gheorghe I. Gheorghe .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer International Publishing AG, part of Springer Nature

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Gheorghe, G.I., Donțu, O., Băran, N., Moga, I.C., Constantin, M., Tămășanu, E. (2019). Researches on the Measurement of the Dissolved Oxygen Concentration in Stationary Waters. In: Gheorghe, G. (eds) Proceedings of the International Conference of Mechatronics and Cyber-MixMechatronics – 2018. ICOMECYME 2018. Lecture Notes in Networks and Systems, vol 48. Springer, Cham. https://doi.org/10.1007/978-3-319-96358-7_4

Download citation

Publish with us

Policies and ethics