Abstract
Modernization of anesthesia delivery equipment and monitoring, as well as improvements in provider training, has led to a decline in reportable adverse events in the Anesthesia Closed Claims database. Anesthesia providers should be trained on the recognition and management of common equipment failures to reduce the risk of patient injury. Training should occur through a combination of studied learning, on-site training, and simulation training. Anesthesia providers should be competent in performing all aspects of the pre-anesthesia machine checklist and be aware of common equipment problems, the risk of patient injury, how to react when equipment failure occurs, and how to best prevent equipment from happening in the first place or resulting in patient harm.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsBibliography
Sub-Committee of ASA Committee on Equipment and Facilities. Recommendations for pre-anesthesia checkout procedures. 2008. Retrieved from https://www.asahq.org/resources/clinical-information/2008-asa-recommendations-for-pre-anesthesia-checkout
Al Suhaibani M, Al Malki A, Al Dosary S, Al Barmawi H, Pogoku M. Pre-use anesthesia machine check; certified anesthesia technician based quality improvement audit. Anesth Essays Res. 2014;8(3):354–60. https://doi.org/10.4103/0259-1162.143142.
Goneppanavar U, Prabhu M. Anaesthesia machine: checklist, hazards, scavenging. Indian J Anaesth. 2013;57(5):533–40. https://doi.org/10.4103/0019-5049.120151.
Association of Anaesthetists of Great Britain and Ireland (AAGBI), Hartle A, Anderson E, Bythell V, Gemmell L, Jones H, et al. Checking anaesthetic equipment 2012: association of anaesthetists of Great Britain and Ireland. Anaesthesia. 2012;67(6):660–8. https://doi.org/10.1111/j.1365-2044.2012.07163.x.
Cassinello F, Ariño JJ, Bartolomé Ruibal A, de la Pinta JC, de la Quintana FB, Espinosa ME, Grupo de Trabajo de la Sociedad Española de Anestesiología, Reanimación y Tratamiento del Dolor para el desarrollo de Directrices para procedimientos de chequeos previos a la anestesia de la SEDAR, et al. Spanish Society of Anaesthesia (SEDAR) guidelines for pre-anaesthesia checking procedures. Revista Espanola de Anestesiologia Y Reanimacion. 2012;59(4):210–6. https://doi.org/10.1016/j.redar.2012.03.002.
Dobson G, Chong M, Chow L, Flexman A, Kurrek M, Laflamme C, et al. Guidelines to the practice of anesthesia – revised edition 2017. Can J Anaesth. 2017;64(1):65–91. https://doi.org/10.1007/s12630-016-0749-0.
Caplan RA, Vistica MF, Posner KL, Cheney FW. Adverse anesthetic outcomes arising from gas delivery equipment: a closed claims analysis. Anesthesiology. 1997;87(4):741–8. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/9357874
Mehta SP, Eisenkraft JB, Posner KL, Domino KB. Patient injuries from anesthesia gas delivery equipment: a closed claims update. Anesthesiology. 2013;119(4):788–95. https://doi.org/10.1097/ALN.0b013e3182a10b5e.
Woodcock BJ. Mechanical ventilators. In: Lobato EB, Gravenstein N, Kirby RR, editors. Complications in Anesthesia. 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2007. p. 1,008.
Abel M, Eisenkraft JB. Vaporizers. In: Lobato EB, Gravenstein N, Kirby RR, editors. Complications in anesthesia. 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2007. p. 1009.
Gaba DM. Anaesthesiology as a model for patient safety in health care. BMJ (Clinical Research Ed). 2000;320(7237):785–8. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/10720368
Aitkenhead AR. Injuries associated with anaesthesia. A global perspective. Br J Anaesth. 2005;95(1):95–109. https://doi.org/10.1093/bja/aei132.
Schwilk B, Muche R, Bothner U, Goertz A, Friesdorf W, Georgieff M. Quality control in anesthesiology. Results of a prospective study following the recommendations of the German Society of Anesthesiology and Intensive Care. Anaesthesist. 1995;44(4):242–9. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/7785752
Waldrop WB, Murray DJ, Boulet JR, Kras JF. Management of anesthesia equipment failure: a simulation-based resident skill assessment. Anesth Analg. 2009;109:426–33.
Mudumbai SC, Fanning R, Howard SK, Davies MF, Gaba DM. Use of medical simulation to explore equipment failures and human-machine interactions in anesthesia machine pipeline supply crossover. Anesth Analg. 2010;110:1292–6.
Woodworth G, Kirsch JR, Sayers-Rana S. The Anesthesia technician and technologist’s manual: all you need to know for study: Lippincott Williams & Wilkins; 2012.
Yang KK, Lewis IH. Mask induction despite circuit obstruction: an unrecognized hazard of relying on automated machine check technology. Anesth Analg Case Rep. 2014;2:143–6.
Moreno-Duarte I, Montenegro J, Balonov K, Schumann R. Increased resistance to flow and ventilator failure secondary to faulty CO2 absorbent insert not detected during automated anesthesia machine check: a case report. Anesth Analg Case Rep. 2017;8:192–6.
Eng TS, Durieux ME. Automated machine checkout leaves an internal gas leak undetected: the need for complete checkout procedures. Anesth Analg. 2012;114:144–6.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Homra, B., Clark, A. (2019). Equipment Problems. In: Fox, III, C., Cornett, E., Ghali, G. (eds) Catastrophic Perioperative Complications and Management. Springer, Cham. https://doi.org/10.1007/978-3-319-96125-5_21
Download citation
DOI: https://doi.org/10.1007/978-3-319-96125-5_21
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-96124-8
Online ISBN: 978-3-319-96125-5
eBook Packages: MedicineMedicine (R0)