Skip to main content

Development of a Miniaturized Focused Shock Wave Generator for Medical Application

  • Conference paper
  • First Online:
31st International Symposium on Shock Waves 2 (ISSW 2017)

Included in the following conference series:

  • 1046 Accesses

Abstract

This paper reports the result of development of a miniaturized focused shock wave generator for a technological innovation in minimally invasive therapy. The focused shock waves generated from the tip of the shock wave ablation catheter reached 80 MPa of peak pressure and successfully damaged a slab of fresh potato. The depth of damaged area and the pulse laser energy were related to positive correlation. These results indicate the potential usefulness of our new shock wave ablation system.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 299.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 379.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. R.K. Thakur, G.J. Klein, R. Yee, Radiofrequency catheter ablation in patients with Wolf-Parkinson-White syndrome. Can. Med. Assoc. J. 151(6), 771–776 (1994)

    Google Scholar 

  2. J.J. Rasswiler, T. Knoll, K. Köhrmann, J.A. MacAteer, J.E. Lingeman, R.O. Cleveland, M.R. Bailey, C. Chaussy, Shock wave technology and application: An update. Eur. Urol. 59, 784–796 (2011)

    Article  Google Scholar 

  3. Y. Hasebe, H. Yamamoto, K. Fukuda, K. Nishimiya, K. Hanawa, T. Shindo, M. Kondo, M. Nakano, Y. Wakayama, K. Takayama, H. Shimokawa, Development of a novel shock wave catheter ablation system – the first feasibility study in pigs. PLoS One 10(1), e0116017 (2015)

    Article  Google Scholar 

  4. P. Sunka, V. Babicky, M. Clupek, J. Benes, P. Pouckova, Localized damage of tissues induced by focused shock waves. IEEE Trans. Plasma Sci 32(4), 1609–1613 (2004)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Yamamoto .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Yamamoto, H., Takayama, K., Shimokawa, H. (2019). Development of a Miniaturized Focused Shock Wave Generator for Medical Application. In: Sasoh, A., Aoki, T., Katayama, M. (eds) 31st International Symposium on Shock Waves 2. ISSW 2017. Springer, Cham. https://doi.org/10.1007/978-3-319-91017-8_50

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-91017-8_50

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-91016-1

  • Online ISBN: 978-3-319-91017-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics