Introduction

  • Jiawei Xu
  • Refet Firat Yazicioglu
  • Chris Van Hoof
  • Kofi Makinwa
Chapter
Part of the Analog Circuits and Signal Processing book series (ACSP)

Abstract

Electroencephalography (EEG) acquisition in a wearable form factor is a very important noninvasive solution for long-term brain monitoring. This chapter introduces the basic working principle of scalp EEG measurement, the developing history, and the practical need for personal EEG devices. Conventional EEG systems with passive electrodes are widely used in modern clinical practice. However, they rely on gel electrodes which are not suitable for user-friendly EEG recording. Alternatively, active electrode (AE)-based EEG systems are promising solution for wearable EEG because they are easy to use and compatible with dry electrodes. This chapter summarizes the benefits of AEs and their associated design challenges for medical applications.

Keywords

EEG Active electrodes Wearable Dry electrodes BCI 

References

  1. 1.
  2. 2.
    O.V. Lounasmaa et al., Information processing in the human brain – Magnetoencephalographic approach. Proc. Natl. Acad. Sci. U. S. A. 93, 8809–8815 (1996)CrossRefGoogle Scholar
  3. 3.
    EEGinfo. What is neurofeedback? [online] available at: https://www.eeginfo.com/what-is-neurofeedback.jsp
  4. 4.
    D.E. Bloom et al., The global economic burden of noncommunicable diseases (World Economic Forum, Geneva, 2011)Google Scholar
  5. 5.
    Transparency Market Research. [online] available at: http://www.transparencymarketresearch.com/wearable-medical-devices.html
  6. 6.
    G.B. Marson, J.B. McKinnon, A miniature tape recorder for many applications. Control. Instrum. 4, 46–47 (1972)Google Scholar
  7. 7.
    IBVA. [online] available at: http://www.ibva.co.uk/eeg.htm
  8. 8.
    Neurofax EEG-1100 System (1999), Nihon KohdenGoogle Scholar
  9. 9.
    g.tec IntendiX. [online] available at: http://www.cortechsolutions.com/Products/DA/DA-IX
  10. 10.
    imec EEG headset (2012). [online] available at: http://www2.imec.be/be_en/press/imec-news/imeceeg2012.html
  11. 11.
    Cognionics, 72-Channel Dry EEG Headset System. [online] available at: http://www.cognionics.com
  12. 12.
    Emotiv. [online] available at: https://emotiv.com/
  13. 13.
    Y.M. Chi, T.-P. Jung, G. Cauwenberghs, Dry-contact and noncontact biopotential electrodes: Methodological review. IEEE Rev. Biomed. Eng. 3, 106–119 (2010)CrossRefGoogle Scholar
  14. 14.
    A. Searle, L. Kirkup, A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol. Meas. 21(2), 271 (2000)CrossRefGoogle Scholar
  15. 15.
    S. Lee, J. Kruse, Biopotential electrode sensors in ECG/EEG/EMG systems. Analog Devices 200, 1–2 (2008)Google Scholar
  16. 16.
    A.C. Metting-van Rijn et al., High-quality recording of bioelectric events. Part 2. Low-noise, low-power multichannel amplifier design. Med. Biol. Eng. Comput. 29(4), 433–440 (1991)CrossRefGoogle Scholar
  17. 17.
    C.J. Harland et al., Electric potential probes – New directions in the remote sensing of the human body. Meas. Sci. Technol 13, 163 (2002)CrossRefGoogle Scholar
  18. 18.
    T. Degen et al., Low-noise two-wired buffer electrodes for bioelectric amplifiers. IEEE Trans. Biomed. Eng. 54, 1328–1332 (2007)CrossRefGoogle Scholar
  19. 19.
    F.Z. Padmadinata et al., Microelectronic skin electrode. Sens. Actuators B Chem. 1(1–6), 491–494 (1990)CrossRefGoogle Scholar
  20. 20.
    J. Xu, R. F. Yazicioglu, P. Harpe, K. A. A. Makinwa, C. Van Hoof, A 160μW 8-channel active electrode system for EEG monitoring, Digest of ISSCC, (Feb. 2011), pp. 300–302Google Scholar
  21. 21.
    IEC60601-2-26, Medical electrical equipment – Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs, (2012)Google Scholar
  22. 22.
    M.R. Nuwer et al., IFCN standards for digital recording of clinical EEG. Electroencephalogr. Clin. Neurophysiol. 106(3), 259–261 (1998)CrossRefGoogle Scholar
  23. 23.
    H. Aurlien et al., EEG background activity described by a largecomputerized database. Clin. Neurophysiol. 115(3), 665–673 (2004)CrossRefGoogle Scholar
  24. 24.
    IEC60601-2-26, 3rd Edition, Medical electrical equipment – Part 2-26: Particular requirements for basic safety and essential performance of electroencephalographs, (2012)Google Scholar
  25. 25.
    S. Kim et al., A 2.4μA continuous-time electrode-skin impedance measurement circuit for motion artifact monitoring in ECG acquisition systems, Digest of Symp. VLSI Circuits, (June. 2010), pp. 219–220Google Scholar
  26. 26.
    M. Guermandi, R. Cardu, E. Franchi, R. Guerrieri, Active electrode IC combining EEG, electrical impedance tomography, continuous contact impedance measurement and power supply on a single wire, Digest of ESSCIRC, (Sept. 2011), pp. 335–338Google Scholar
  27. 27.
    Datasheet LIR2450 – Multicomp, Coin Cell, Lithium, 120mAh, 3.6V. [online] available at: https://www.powerstream.com/p/Lir2450.pdf

Copyright information

© Springer International Publishing AG 2018

Authors and Affiliations

  • Jiawei Xu
    • 1
  • Refet Firat Yazicioglu
    • 2
  • Chris Van Hoof
    • 3
  • Kofi Makinwa
    • 4
  1. 1.Holst Centre / imecEindhovenThe Netherlands
  2. 2.Galvani BioelectronicsStevenageUK
  3. 3.ESAT-MICASKU Leuven / imecLeuvenBelgium
  4. 4.Delft University of TechnologyDelftThe Netherlands

Personalised recommendations