Skip to main content

Custom Manipulation of Corneal Asphericity (The Q Factor)

  • Chapter
  • First Online:
  • 859 Accesses

Abstract

When ablating the cornea with a myopic wavefront optimized (WFO) or aberration-free profile, the cornea is always going to receive more ablation in the centre than in the periphery of the optical zone and this will lead to the induction of spherical aberration. With manipulation of corneal asphericity, the final corneal asphericity can be influenced to preserve more natural prolateness than would otherwise occur. Asphericity-guided (Q-adjusted) procedures can also be used to induce corneal asphericity that enhances depth of field (hyper-prolate cornea). This is sometimes used in procedures called “Advanced monovision” due to the fact that the reading eye has better distance vision than would be the case in a patient with straight-forward monovision. Additional reasons for using an asphericity-guided ablation profile would be that for higher myopic corrections, the ablation depth is usually less than with a wavefront-optimised profile. Additionally, the refraction can be refined to 0.01D and the optical zone can be increased in 0.1 mm increments as opposed to 0.5 mm increments in WFO treatments. The target-Q can also be used to either attempt to preserve the preoperative Q-value (that is, not inducing any change) or a different Q-value could be targeted to create negative asphericity and increased depth of field for advanced monovision treatments.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   69.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   99.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   119.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Gatinel D, Haouat M, Hoang-Xuan T. A review of mathematical descriptors of corneal asphericity. J Fr Ophtalmol. 2002;25(1):81–90.

    PubMed  CAS  Google Scholar 

  2. Seiler T, Koller T. Asphericity of the cornea and astigmatism. Klin Monatsbl Augenheilkd. 2005;222(12):977–82.

    Article  CAS  PubMed  Google Scholar 

  3. Amigo A, Bonaque-Gonzalez S. Q factor Presbylasik. Fundamentals and therapeutic approach. J Emmetropia. 2012;3:167–71.

    Google Scholar 

  4. Gatinel D, Malet J, Hoang-Xuan T, Azar DT. Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity. Invest Ophthalmol Vis Sci. 2002;43(4):941–8.

    PubMed  Google Scholar 

  5. Amigo A, Bonaque S, Lopez-Gil N, Thibos L. Simulated effect of corneal asphericity increase (Q-factor) as a refractive therapy for presbyopia. J Refract Surg. 2012;28(6):413–8.

    Article  PubMed  Google Scholar 

  6. Calossi A. Corneal asphericity and spherical aberration. J Refract Surg. 2007;23(5):505–14.

    PubMed  Google Scholar 

  7. Dorronsoro C, Remon L, Merayo-Lloves J, Marcos S. Experimental evaluation of optimized ablation patterns for laser refractive surgery. Opt Express. 2009;17(17):15292–307.

    Article  CAS  PubMed  Google Scholar 

  8. Alio JL, Amparo F, Ortiz D, Moreno L. Corneal multifocality with excimer laser for presbyopia correction. Curr Opin Ophthalmol. 2009;20(4):264–71.

    Article  PubMed  Google Scholar 

  9. Vargas-Fragoso V, Alio JL. Corneal compensation of presbyopia: PresbyLASIK: an updated review. Eye Vis (Lond). 2017;4:11.

    Article  Google Scholar 

  10. Courtin R, Saad A, Grise-Dulac A, Guilbert E, Gatinel D. Changes to corneal aberrations and vision after monovision in patients with hyperopia after using a customized aspheric ablation profile to increase corneal asphericity (Q-factor). J Refract Surg. 2016;32(11):734–41.

    Article  PubMed  Google Scholar 

  11. Gatinel D. Presbyopia surgery. Rev Prat. 2008;58(10):1049–54.

    PubMed  Google Scholar 

  12. Gatinel D, Azar DT, Dumas L, Malet J. Effect of anterior corneal surface asphericity modification on fourth-order zernike spherical aberrations. J Refract Surg. 2014;30(10):708–15.

    Article  PubMed  Google Scholar 

  13. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for presbyopia correction in emmetropic patients using aspheric ablation profiles and a micro-monovision protocol with the Carl Zeiss Meditec MEL 80 and VisuMax. J Refract Surg. 2012;28(8):531–41.

    Article  PubMed  Google Scholar 

  14. Reinstein DZ, Archer TJ, Gobbe M. LASIK for myopic astigmatism and presbyopia using non-linear aspheric micro-Monovision with the Carl Zeiss Meditec MEL 80 platform. J Refract Surg. 2011;27(1):23–37.

    Article  PubMed  Google Scholar 

  15. Reinstein DZ, Archer TJ, Gobbe M. Aspheric ablation profile for presbyopic corneal treatment using the MEL80 and CRS Master Laser blended vision module. J Emmetropia. 2011;2(3):161–75.

    Google Scholar 

  16. Wang Yin GH, McAlinden C, Pieri E, Giulardi C, Holweck G, Hoffart L. Surgical treatment of presbyopia with central presbyopic keratomileusis: one-year results. J Cataract Refract Surg. 2016;42(10):1415–23.

    Article  PubMed  Google Scholar 

  17. Vastardis I, Gatzioufas Z, Pajic BE, Muller J, Pajic B. Multifocal corneal excimer femtosecond laser in situ Keratomileusis following radial keratotomy: a case report with six months of follow-up. Case Rep Ophthalmol. 2014;5(3):423–8.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Koller T, Iseli HP, Hafezi F, Mrochen M, Seiler T. Q-factor customized ablation profile for the correction of myopic astigmatism. J Cataract Refract Surg. 2006;32(4):584–9.

    Article  PubMed  Google Scholar 

  19. Stojanovic A, Wang L, Jankov MR, Nitter TA, Wang Q. Wavefront optimized versus custom-Q treatments in surface ablation for myopic astigmatism with the WaveLight ALLEGRETTO laser. J Refract Surg. 2008;24(8):779–89.

    PubMed  Google Scholar 

  20. Matalia H, Francis M, Gangil T, et al. Noncontact quantification of topography of anterior corneal surface and Bowman’s layer with high-speed OCT. J Refract Surg. 2017;33(5):330–6.

    Article  PubMed  Google Scholar 

  21. Salomao MQ, Hofling-Lima AL, Lopes BT, et al. Role of the corneal epithelium measurements in keratorefractive surgery. Curr Opin Ophthalmol. 2017;28(4):326–36.

    Article  PubMed  Google Scholar 

  22. Gualdi LGF, Rusciano D, Ambrósio R Jr, Salomão MQ, Lopes BT, Capello V, Fintina T, Gualdi M. Ciliary muscle electrostimulation to restore accommodation (CMERA) in patients with early presbyopia: preliminary results. J Refract Surg. 2017;33(9):578.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Arthur B. Cummings .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG, part of Springer Nature

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Faria-Correia, F., Ambrósio, R., Mendes, J.F., Cummings, A.B. (2018). Custom Manipulation of Corneal Asphericity (The Q Factor). In: Sinjab, M., Cummings, A. (eds) Customized Laser Vision Correction. Springer, Cham. https://doi.org/10.1007/978-3-319-72263-4_7

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-72263-4_7

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-72262-7

  • Online ISBN: 978-3-319-72263-4

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics