Skip to main content

Impact of Distributed Generation on Power Quality in Medium Voltage Distribution Networks

  • Conference paper
  • First Online:
Advanced Technologies, Systems, and Applications II (IAT 2017)

Abstract

This paper provides an analysis of the impact of mini hydropower plant “Kordići” on the 20 kV distribution network of Bugojno area in terms of power quality. Therefore, measurement and evaluation of the quality of the supplied power was carried out at the point of common coupling between the mini hydropower plant and the distribution network. Measurement was carried out for the period from March 7 to March 18, 2016 and the data were evaluated in accordance with EN 50160 standard.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Jusic, A.: Analysis of the impact of the first synchronization of MHP “Kordići” on the 20 kV distribution network of Bugojno area. University of Sarajevo, Faculty of Electrical Engineering (2016)

    Google Scholar 

  2. Ferracci, P.: Power Quality. Cahiers Techniques no. 199, Schneider Electric (2001)

    Google Scholar 

  3. Dugan, R.C., McGranaghan, M.F., Santoso, S., Beaty, H.W.: Electrical Power Systems Quality, 2nd edn. The McGraw-Hill Companies (2004)

    Google Scholar 

  4. Tesařová, M.: Power Quality and Quality of Supply. Železná Ruda-Špičák, University of West Bohemia, Czech Republic (2011)

    Google Scholar 

  5. Markiewicz, H., Klajn, A.: Voltage Disturbances, Standard EN 50160—Voltage Characteristics of Public Distribution Systems. Wroclaw University of Technology (2004)

    Google Scholar 

  6. de Almeida, A., Moreira, L., Delgado, J.: Power Quality Problems and New Solutions. ISR—Department of Electrical and Computer Engineering, University of Coimbra (2003)

    Google Scholar 

  7. European standard EN 50160: Voltage characteristics of electricity supplied by public distribution systems

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alija Jusić .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Jusić, A., Jareb, E., Bajramović, Z. (2018). Impact of Distributed Generation on Power Quality in Medium Voltage Distribution Networks. In: Hadžikadić, M., Avdaković, S. (eds) Advanced Technologies, Systems, and Applications II. IAT 2017. Lecture Notes in Networks and Systems, vol 28. Springer, Cham. https://doi.org/10.1007/978-3-319-71321-2_39

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-71321-2_39

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-71320-5

  • Online ISBN: 978-3-319-71321-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics