Abstract
Approaches used to evaluate passive measures related to residential buildings deal principally with their incidence in energy demand and overheating risks. The first approach considers that all buildings are equipped with air conditioning systems, and the second one that they are naturally conditioned. But in the Mediterranean Region, due to different climate severities, and considering socio-economically vulnerable population, these systems may not exist, cannot be used, or have a very limited use. On the other hand, evaluation of indoor thermal environments should take into account that population living in residential buildings are intergenerational and varied, and should all be protected from future changing conditions through a Climate-Ready Architecture. Case Studies of two typical residential building typologies located in ten different locations in Southern Europe have been studied from both approaches, allowing an assessment of this challenge.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsNotes
- 1.
Oporto is excluded in the mean values of cooling demand in these cases, due to its low demand.
- 2.
In the current scenario and in T5 Typology, only cooling demand percentages in first floor are considered because in the ground floor, demand increase is very variable. However, both floors are considered in mean energy demand values (kWh/m2 a).
- 3.
Oporto is excluded in the average values of cooling demand in these cases, due to its low-energy demand.
- 4.
Footnote 3 Idem.
- 5.
In the current scenario and in T5 typology, only first floor cooling demands are considered, since on the ground floor the increase in demand is quite variable. In absolute values, both floors are considered.
- 6.
In T1 Typology, with a sloped roof with ceramic tiles, variation in roof’s albedo has not been considered since it is not a usual solution.
References
ASHRAE55-2013. (2013). Thermal Environmental Conditions for Human Occupancy.
Brotas, L., & Nicol, J. F. (2016). The problem of overheating in European dwellings. Windsor, 2016(April), 7–10.
CTE-HE. (2013). Documento Básico CTE-HE Ahorro de energía. Septiembre. Retrieved from http://www.codigotecnico.org/images/stories/pdf/ahorroEnergia/DBHE.pdf.
EEA. (2016). Climate change, impacts and vulnerability in Europe 2016 - Key findings. EEA Report. https://doi.org/10.2800/66071.
Huang, J. (2011). ASHRAE Research Project 1477-RP Development of 3,012 typical year weather files for international locations. Final Report.
Jentsch, M. F., James, P. A. B., Bourikas, L., & Bahaj, A. S. (2013). Transforming existing weather data for worldwide locations to enable energy and building performance simulation under future climates. Renewable Energy, 55, 514–524. https://doi.org/10.1016/j.renene.2012.12.049.
Psomas, T., Heiselberg, P., Duer, K., & Bjorn, E. (2016). Overheating risk barriers to energy renovations of single family houses: Multicriteria analysis and assessment. Energy and Buildings, 117, 138–148. https://doi.org/10.1016/j.enbuild.2016.02.031.
Rodriguez-Vidal, I. (2016). Evaluación del estándar de construcción Passivhaus y su aplicación en el ámbito climático de la Comunidad Autónoma Vasca y la Comunidad Foral Navarra. El caso de la vivienda colectiva de protección oficial. Retrieved from http://hdl.handle.net/10810/17870
Saman, W., Boland, J., Pullen, S., Dear, R. De, Soebarto, V., Miller, W., … Chileshe, N. (2013). A framework for adaptation of Australian households to heat waves. Retrieved from http://www.nccarf.edu.au/sites/default/files/attached_files_publications/Saman_2013_Adapting_households_to_heat_waves.pdf.
UCLA. (n.d.). http://www.energy-design-tools.aud.ucla.edu/.
UNE-EN 15251. (2008). Parámetros del ambiente interior a considerar para el diseño y la evaluación de la eficiencia energética de edificios incluyendo la calidad del aire interior, condiciones térmicas, iluminación y ruido.
Acknowledgements
We would like to thank María Dolores Juri, student in the Master’s Degree in Environmental Management and Building Design, MDGAE in University of Navarra (Spain), who carry out the Master’s Thesis titled ‘Resiliencia al cambio climático en viviendas del sur de Europa de climas mediterráneos’. Also to Cristina Guell, for her assistance in the elaboration of overheating graphs.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this chapter
Cite this chapter
Monge-Barrio, A., Sánchez-Ostiz Gutiérrez, A. (2018). Incidence of Passive Measures in a Climate-Ready Architecture. Attending to Energy Demands and Overheating Risks. In: Passive Energy Strategies for Mediterranean Residential Buildings. Green Energy and Technology. Springer, Cham. https://doi.org/10.1007/978-3-319-69883-0_8
Download citation
DOI: https://doi.org/10.1007/978-3-319-69883-0_8
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-69882-3
Online ISBN: 978-3-319-69883-0
eBook Packages: EnergyEnergy (R0)