Abstract

In the last decade, electrophysiological models for in-silico simulations of cardiac electrophysiology have gained much attention in the research field. However, to translate them to clinical uses, the models need personalization based on recordings from the patient. In this work, we explore methodologies for the patient-specific personalization of torso and heart geometric models based on standard clinical cardiac magnetic resonance acquisitions to enable simulations. The inclusion of the torso and its internal structures allows simulations of the human ventricular electrophysiological activity from the ionic level to the body surface potentials and to the electrocardiogram.

Notes

Acknowledgments

EZ acknowledges the Marie Sklodowska-Curie Individual Fellowship from the H2020 EU Framework Programme for Research and Innovation (Proposal No: 655020-DTI4micro-MSCA-IF-EF-ST). AM and BR are supported by BR’s Wellcome Trust Senior Research Fellowship in Basic Biomedical Sciences, the CompBiomed project (grant agreement No 675451) and the NC3R Infrastructure for Impact award (NC/P001076/1). BV acknowledges the support of the RCUK Digital Economy Programme grant number EP/G036861/1 (Oxford Centre for Doctoral Training in Healthcare Innovation). VC was supported by ERACoSysMed through a grant to the project SysAFib - Systems medicine for diagnosis and stratification of atrial fibrillation. RA is supported by a British Heart Foundation Clinical Research Training Fellowship. VG is supported by a BBSRC grant (BB/I012117/1), an EPSRC grant (EP/J013250/1), by BHF New Horizon Grant NH/13/30238 and by the CompBiomed project (grant agreement No 675451).

References

  1. 1.
    Arevalo, H., et al.: Arrhythmia risk stratification of patients after myocardial infarction using personalized heart models. Nature Commun. 7, 11437 (2016)CrossRefGoogle Scholar
  2. 2.
    Zettinig, O., et al.: From medical images to fast computational models of heart electromechanics: an integrated framework towards clinical use. In: Ourselin, S., Rueckert, D., Smith, N. (eds.) FIMH 2013. LNCS, vol. 7945, pp. 249–258. Springer, Heidelberg (2013). doi: 10.1007/978-3-642-38899-6_30 CrossRefGoogle Scholar
  3. 3.
    Peng, P., et al.: A review of heart chamber segmentation for structural and functional analysis using cardiac MRI. Magn. Reson. Mater. Phys. 29(2), 155–195 (2016)MathSciNetCrossRefGoogle Scholar
  4. 4.
    Heiberg, E., et al.: Design and validation of segment - freely available software for cardiovascular image analysis. BMC Med. Imaging 10(1), 1 (2010)CrossRefGoogle Scholar
  5. 5.
    Schulz-Menger, J., et al.: Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for cardiovascular magnetic resonance (SCMR) board of trustees task force on standardized post processing. J. Cardiovasc. Magn. Reson. 15(1), 35 (2013)CrossRefGoogle Scholar
  6. 6.
    Prakash, R.: Determination of right ventricular wall thickness in systole and diastole. Echocardiographic and necropsy correlation in 32 patients. Heart 40(11), 1257–1261 (1978)CrossRefGoogle Scholar
  7. 7.
    Villard, B., Zacur, E., Dall’Armellina, E., Grau, V.: Correction of slice misalignment in multi-breath-hold cardiac MRI scans. In: Mansi, T., McLeod, K., Pop, M., Rhode, K., Sermesant, M., Young, A. (eds.) STACOM 2016. LNCS, vol. 10124, pp. 30–38. Springer, Cham (2017). doi: 10.1007/978-3-319-52718-5_4 CrossRefGoogle Scholar
  8. 8.
    Villard, B., et al.: Cardiac mesh reconstruction from sparse, heterogeneous contours. In: Valdés Hernández, M., González-Castro, V. (eds.) MIUA 2017. CCIS, vol. 723, pp. 169–181. Springer, Cham (2017)Google Scholar
  9. 9.
    Zhu, S., et al.: An efficient human model customization method based on orthogonal view monocular photos. Comput. Aided Des. 45(11), 1314–1332 (2013)CrossRefGoogle Scholar
  10. 10.
    Zettinig, O., et al.: Data-driven estimation of cardiac electrical diffusivity from 12-lead ECG signals. Med. Image Anal. 18(8), 1361–1376 (2014)CrossRefGoogle Scholar
  11. 11.
    Gillette, K., et al.: Generation of combined-modality tetrahedral meshes. In: Proceedings CinC 2015 (2015)Google Scholar
  12. 12.
    Trayanova, N., et al.: How computer simulations of the human heart can improve anti-arrhythmia therapy. J. Physiol. 594(9), 2483–2502 (2016)CrossRefGoogle Scholar
  13. 13.
    Pishchulin, L., et al.: Building statistical shape spaces for 3D human modeling. Pattern Recogn. 67, 276–286 (2017)CrossRefGoogle Scholar
  14. 14.
    Rohr, K., et al.: Landmark-based elastic registration using approximating thin-plate splines. IEEE Trans. Med. Imaging 20(6), 526–534 (2001)CrossRefGoogle Scholar
  15. 15.
    Amberg, B., et al.: Optimal step nonrigid ICP algorithms for surface registration. In: Proceedings IEEE CVPR 2007 (2007)Google Scholar
  16. 16.
    Geneser, S., et al.: Application of stochastic FEM to study the sensitivity of ECG forward modeling to organ conductivity. IEEE Trans. Biomed. Eng. 55(1), 31–40 (2008)CrossRefGoogle Scholar
  17. 17.
    Keller, D., et al.: Ranking the influence of tissue conductivities on forward-calculated ECGs. IEEE Trans. Biomed. Eng. 57(7), 1568–1576 (2010)CrossRefGoogle Scholar
  18. 18.
    Bernabeu, M., et al.: Shock-induced arrhythmogenesis in the human heart: a computational modelling study. In: Proceedings IEEE EMBS 2010 (2010)Google Scholar
  19. 19.
    Engwirda, D.: Locally-optimal Delaunay-refinement and optimisation-based mesh generation. Ph.D. thesis, The University of Sydney (2014)Google Scholar
  20. 20.
    Hang, S.: TetGen, a Delaunay-based quality tetrahedral mesh generator. ACM Trans. Math. Softw. 41(2), 11:1–11:36 (2015)Google Scholar
  21. 21.
    Pitt-Francis, J., et al.: Chaste: a test-driven approach to software development for biological modelling. Comput. Phys. Commun. 180(12), 2452–2471 (2009)MathSciNetCrossRefzbMATHGoogle Scholar
  22. 22.
    Cardone-Noott, L., et al.: Human ventricular activation sequence and the simulation of the electrocardiographic QRS complex and its variability in healthy and intraventricular block conditions. EP Europace 18(suppl. 4), iv4–iv15 (2016)Google Scholar
  23. 23.
    Streeter, D.: Gross Morphology and Fiber Geometry of the Heart. Johns Hopkins Press, Baltimore (1979)Google Scholar

Copyright information

© Springer International Publishing AG 2017

Authors and Affiliations

  • Ernesto Zacur
    • 1
    Email author
  • Ana Minchole
    • 2
  • Benjamin Villard
    • 1
  • Valentina Carapella
    • 4
  • Rina Ariga
    • 3
  • Blanca Rodriguez
    • 2
  • Vicente Grau
    • 1
  1. 1.Department of Engineering Science, Institute of Biomedical EngineeringUniversity of OxfordOxfordUK
  2. 2.Department of Computer ScienceUniversity of OxfordOxfordUK
  3. 3.Division of Cardiovascular MedicineUniversity of Oxford Centre for Clinical Magnetic Resonance ResearchOxfordUK
  4. 4.Simula Research LaboratoryBærumNorway

Personalised recommendations