Abstract
Intracranial electrode arrays for recording and stimulating electrical brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. When compared to scalp electroencephalography (EEG), cortical recordings have demonstrated superior spatial resolution and consequently a greater potential for cognitive command output. Traditional cortical arrays require direct implantation into the brain via open craniotomy, which is a delicate and lengthy procedure. This can lead to inflammatory tissue responses amongst other clinical complications and has necessitated the development of minimally invasive methods that circumvent or mitigate brain trauma. In this study, we demonstrate the feasibility of chronically recording brain activity from within an external cerebral vein using a passive stent - electrode recording array (stentrode). We achieved implantation into a superficial cortical vein lying adjacent to the motor cortex using catheter angiography. Access was made via vascular puncture in the external jugular vein in the neck. Following successful implantation, we demonstrated neural recordings in freely moving sheep for time periods up to 190 days. Venous internal lumen patency was preserved for the duration of implantation. Spectral content and bandwidth of vascular electrocorticography were found to be comparable to those of recordings from epidural surface arrays.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Deuschl G, Schade-Brittinger C, Krack P et al (2006) A randomized trial of deep-brain stimulation for parkinson’s Disease. N Engl J Med 355:896–908. doi:10.1056/NEJMoa060281
Cook MJ, O’Brien TJ, Berkovic SF et al (2013) Prediction of seizure likelihood with a long-term, implanted seizure advisory system in patients with drug-resistant epilepsy: A first-in-man study. Lancet Neurol 12:563–571. doi:10.1016/S1474-4422(13)70075-9
Morrell MJ (2011) Responsive cortical stimulation for the treatment of medically intractable partial epilepsy. Neurology 77:1295–1304. doi:10.1212/WNL.0b013e3182302056
Hochberg LR, Serruya MD, Friehs GM et al (2006) Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 442:164–171. doi:10.1038/nature04970
Yanagisawa T, Hirata M, Saitoh Y et al (2012) Electrocorticographic control of a prosthetic arm in paralyzed patients. Ann Neurol 71:353–361. doi:10.1002/ana.22613
Wilson BS, Finley CC, Lawson DT et al (1991) Better speech recognition with cochlear implants. Nature 352:236–238. doi:10.1038/352236a0
Weiland JD, Cho AK, Humayun MS (2011) Retinal Prostheses: Current Clinical Results and Future Needs. Ophthalmology 118:2227–2237. doi:10.1016/j.ophtha.2011.08.042
Oxley TJ, Opie NL, John SE et al., Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity. Nat Biotechnol 34:320–327. doi:10.1038/nbt.3428
Yanagisawa T, Hirata M, Saitoh Y et al (2009) Neural decoding using gyral and intrasulcal electrocorticograms. Neuroimage 45:1099–1106. doi:10.1016/j.neuroimage.2008.12.069
Chimowitz MI, Lynn MJ, Derdeyn CP et al (2011) Stenting versus Aggressive Medical Therapy for Intracranial Arterial Stenosis. N Engl J Med 365:993–1003. doi:10.1056/NEJMoa1105335
Puffer RC, Mustafa W, Lanzino G (2013) Venous sinus stenting for idiopathic intracranial hypertension: a review of the literature. J Neurointerv Surg 5:483–486. doi:10.1136/neurintsurg-2012-010468
van der Giessen WJ, Serruys PW, van Beusekom HM et al., (1991) Coronary stenting with a new, radiopaque, balloon-expandable endoprosthesis in pigs. Circulation 83:1788LP–1798. http://circ.ahajournals.org/content/83/5/1788.abstract
Watanabe H, Takahashi H, Nakao M et al (2009) Intravascular neural interface with nanowire electrode. Electron Commun Japan 92:29–37. doi:10.1002/ecj.10058
Mikuni N, Ikeda A, Murao K et al (1997) ‘Cavernous Sinus EEG’: A new method for the preoperative evaluation of temporal lobe epilepsy. Epilepsia 38:472–482. doi:10.1111/j.1528-1157.1997.tb01738.x
Bower MR, Stead M, Van Gompel JJ et al (2013) Intravenous recording of intracranial, broadband EEG. J Neurosci Methods 214:21–26. doi:10.1016/j.jneumeth.2012.12.027
Boniface SJ, Antoun N (1997) Endovascular electroencephalography: the technique and its application during carotid amytal assessment. J Neurol Neurosurg Psychiatry 62:193–195
Penn RD, Hilal SK, Michelsen WJ et al (1973) Intravascular intracranial EEG recording - technical note. J Neurosurg 38:239–243. doi:10.3171/jns.1973.38.2.0239
Driller J, Hilal SK, Michelsen WJ et al., (1969) Development and use of the POD catheter in the cerebral vascular system. Med Res Eng 8:11–6. http://europepmc.org/abstract/MED/5823257
Lukatch HS, Kiddoo CE, Maciver MB (2005) Anesthetic-induced burst suppression EEG activity requires glutamate-mediated excitatory synaptic transmission. Cereb Cortex 15:1322–1331. doi:10.1093/cercor/bhi015
Acknowledgements
The Vascular Bionics Laboratory would like to acknowledge all participants and contributors to our work thus far. In particular, we would like to recognise the input of
The University of Melbourne
• Dept. of Medicine
• Dept. of Electrical and Electronic Engineering
The Florey Institute of Neuroscience and Mental Health
The Royal Melbourne Hospital
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 The Author(s)
About this chapter
Cite this chapter
Oxley, T.J. et al. (2017). A Minimally Invasive Endovascular Stent-Electrode Array for Chronic Recordings of Cortical Neural Activity. In: Guger, C., Allison, B., Lebedev, M. (eds) Brain-Computer Interface Research. SpringerBriefs in Electrical and Computer Engineering. Springer, Cham. https://doi.org/10.1007/978-3-319-64373-1_6
Download citation
DOI: https://doi.org/10.1007/978-3-319-64373-1_6
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-64372-4
Online ISBN: 978-3-319-64373-1
eBook Packages: Computer ScienceComputer Science (R0)