Abstract

In 1816, Robert Stirling and James Stirling conceived and patented an external combustion heat engine, which turned by their name and was continuously improved by them over the next 30 years. It is also a reversible cycle like the Carnot cycle and, hence, also has the highest thermal efficiency working between two (high and low) temperatures of source and sink reservoirs, but it has some advantages over the Carnot cycle. The Stirling heat engine consists of two cylinders with two pistons on each side and a regenerator in the middle, which is used for temporary storage of thermal energy. The Stirling engine is a closed system and also required more innovative hardware for execution. In 1833, the Swedish-born engineer John Ericsson developed a different type of hot air, reciprocating, external combustion engine, which could operate on either an open or closed loop cycle.

References

  1. Badescu, V. (1992). Optimum operation of solar convertor in combustion with a Stirling or Ericsson heat engine. Energy, 17, 601–607.CrossRefGoogle Scholar
  2. Blank, D.A., Davis, G.W. and Wu, C. (1994). Power optimization of an endoreversible Stirling cycle with regeneration. Energy, 19, 125–133.CrossRefGoogle Scholar
  3. Blank, D.A. and Wu, C. (1995). Power optimization of an extra-terrestrial solar radiant Stirling heat engine, Energy, 20(6), 523–530.CrossRefGoogle Scholar
  4. Blank, D.A. and Wu, C. (1996a). Power limit of an endoreversible Ericsson cycle with regeneration. Energy Convs. Mgmt, 37, 59–66.CrossRefGoogle Scholar
  5. Blank, D.A. and Wu, C. (1996b). Finite time power limit for solar-radiant Ericsson engines for space applications. Applied Thermal Engineering, 18, 1347–1357.CrossRefGoogle Scholar
  6. Chen, J. (1997a). Optimal performance analysis of irreversible cycles used as heat pumps and refrigerators. J. Phys. D: Appl. Phys, 30, 582–587.ADSCrossRefGoogle Scholar
  7. Chen, J. (1997b). Effect of regenerative losses on the efficiency of Stirling heat engine at maximum power output. Int. Journal of Ambient Energy, 18, 107–112.CrossRefGoogle Scholar
  8. Chen, J. and Schouten, J.A. (1999). The comprehensive influence of several major irreversibilities on the performance of an Ericsson heat engine. Applied Thermal Engineering, 19, 555.CrossRefGoogle Scholar
  9. Chen, J., Yan, Z., Chen, L. and Andresen, B. (1998). Efficiency bound of solar-driven Stirling heat engine system. Int. Journal Energy Res, 22, 805–812.CrossRefGoogle Scholar
  10. Curzon, F.L. and Ahlborn, B. (1975). Efficiency of a Carnot engine at maximum power output. American Journal of Physics, 43, 22–24.ADSCrossRefGoogle Scholar
  11. Erbay, L.B. and Yavuz, H. (1997). Analysis of Stirling heat engine at maximum power conditions. Energy, 22, 645–650.CrossRefGoogle Scholar
  12. Kaushik, S.C. (1999). State-of-the-art on finite time thermodynamics. Internal Report CES, IIT Delhi, India.Google Scholar
  13. Kaushik, S.C. and Kumar, S. (2000a). Finite time thermodynamic analysis of an endoreversibble Stirling heat engine with regenerative losses. Energy, 25, 989–1003.CrossRefGoogle Scholar
  14. Kaushik, S.C. and Kumar, S. (2000b). Finite time thermodynamic evaluation of irreversible Ericsson and Stirling heat pump cycles, Proceedings of 4th Minsk International Seminar on Heat Pipes, Heat Pumps & Refrigerators, Minsk, Belarus 2000b, 113–126.Google Scholar
  15. Kaushik, S.C. and Kumar, S. (2001). Finite time thermodynamic evaluation of irreversible Ericsson and Stirling heat engines. Energy Convers. Mgmt, 42, 295–312.CrossRefGoogle Scholar
  16. Kaushik, S.C. and Tyagi, S.K. (2002). Finite time thermodynamic analysis of a nonisentropic regenerative Brayton heat engine. Int. J. Solar Energy, 22, 141–151.Google Scholar
  17. Kumar, S. (2000). Finite time thermodynamic analysis and second law evaluation of thermal energy conversion systems. Ph.D. Thesis, C.C.S. University, Meerut India.Google Scholar
  18. Ladas, H.G. and Ibrahim, O.M. (1994). Finite time view of Stirling heat engine. Energy, 19, 837–843.CrossRefGoogle Scholar
  19. Senft, J.R. (1998). Theoretical limits on the performance of Stirling engine. Int Journal Energy Res, 22, 991–1000.CrossRefGoogle Scholar
  20. Trukhow, V.S., Tursunbaev, I.A., Lezhebokov, I.A. and Kenzhaev, I.G. (1997). Energy balance of autonomous solar power plant, with the Stirling engine Appl Solar Energy, 33, 17–23.Google Scholar
  21. Tyagi, S.K., Kaushik, S.C. and Salhotra, R. (2002). Ecological optimization and parametric study of irreversible Ericsson and Stirling heat engines. Journal of Phys D: Appl. Phys, 35, 2668–2675.ADSCrossRefGoogle Scholar
  22. Zhou Yinghui, Tyagi S. K., and Chen J., The optimal performance of an irreversible Braysson heat engine cycle, Int. Journal of Thermal Sciences, Vol.43 (2004) pp.1101–1106.Google Scholar

Copyright information

© Capital Publishing Company, New Delhi, India 2017

Authors and Affiliations

  • Shubhash C. Kaushik
    • 1
  • Sudhir K. Tyagi
    • 1
  • Pramod Kumar
    • 2
  1. 1.Centre for Energy StudiesIndian Institute of TechnologyNew DelhiIndia
  2. 2.Solid State Physics Laboratory (SSPL)New DelhiIndia

Personalised recommendations