The Stirling and Ericsson cycles are among the important refrigeration systems for the production of very low temperature, especially in the cryogenic range. These cycles have been utilized by a number of engineering firms in the construction of practical systems and have promoted the development of new design of these cycles for different applications. The reversed Stirling and Ericsson cycles are also called gas refrigeration cycle as gas/air being the working fluid and are very similar to each other. The basic Stirling and Ericsson refrigeration cycles are very similar to each other. These refrigeration cycles also slightly deviate from the reverse Carnot cycle because the adiabatic processes of the latter replaced with the isochoric processes in the Stirling cycle and with the isobaric processes in the Ericsson cycle involving a regenerator for heat transfer during the operation of these cycles. Also the performance of these cycles approaches to the Carnot cycle, as the regenerator efficiency tends to unify, which seldom happens in real practice, and hence, the performance of Stirling and Ericsson cycles is always lesser than that of a Carnot cycle for the same set of operating parameters.

References

  1. Blanchard, C.H. (1980). Coefficient of performance for finite speed heat pump. J. Appl. Phys, 51(5), 2471–2472.ADSCrossRefGoogle Scholar
  2. Chen, J. (1998). Minimum power input of irreversible Stirling refrigerator for given cooling rate. Energy Conv. & Mgmt, 39(12), 1255–1263.CrossRefGoogle Scholar
  3. Curzon, F.L. and Ahlborn, B. (1975). Efficiency of a Carnot engine at maximum power output. American Journal of Physics, 43, 22–24.ADSCrossRefGoogle Scholar
  4. Kaushik, S.C. (1999). State-of-the-art on finite time thermodynamics. Internal Report CES, IIT Delhi, India.Google Scholar
  5. Kaushik, S.C. and Kumar, S. (2000a). Finite time thermodynamic analysis of an endoreversibble Stirling heat engine with regenerative losses. Energy, 25, 989–1003.CrossRefGoogle Scholar
  6. Kaushik, S.C. and Kumar, S. (2000b). Finite time thermodynamic evaluation of irreversible Ericsson and Stirling heat pump cycles, Proceedings of 4th Minsk International Seminar on Heat Pipes, Heat Pumps & Refrigerators, Minsk, Belarus 2000b, 113–126.Google Scholar
  7. Kaushik, S.C. and Tyagi, S.K. (2002). Finite time thermodynamic analysis of a nonisentropic regenerative Brayton heat engine. Int. J. Solar Energy, 22, 141–151.Google Scholar
  8. Kaushik, S.C., Tyagi, S.K., Bose, S.K. and Singhal, M.K. (2002a). Performance evaluation of irrerversible Ericsson and Stirling heat pump cycles. Int. J. Thermal Sciences, 41, 193–200.CrossRefGoogle Scholar
  9. Leff, H.S. and Teeters, W.D. (1978). EER, COP and second law efficiency for airconditioner. Am. J. Phys, 41(1), 19–22.ADSCrossRefGoogle Scholar
  10. Tyagi, S.K., Kaushik, S.C. and Salhotra, R. (2002). Ecological optimization and parametric study of irreversible Ericsson and Stirling heat engines. Journal of Phys D: Appl. Phys, 35, 2668–2675.ADSCrossRefGoogle Scholar
  11. Tyagi, S.K., Wang, S.W. and Park, S.R. (2008). Performance criteria on different pressure ratios of an irreversible modified complex Brayton cycle. Indian Journal of Pure & Applied Physics, 46, 565–574.Google Scholar

Copyright information

© Capital Publishing Company, New Delhi, India 2017

Authors and Affiliations

  • Shubhash C. Kaushik
    • 1
  • Sudhir K. Tyagi
    • 1
  • Pramod Kumar
    • 2
  1. 1.Centre for Energy StudiesIndian Institute of TechnologyNew DelhiIndia
  2. 2.Solid State Physics Laboratory (SSPL)New DelhiIndia

Personalised recommendations