Abstract

Most of the refrigeration cycles discussed so far involve change in phase of the working fluid (refrigerant) while undergoing through different stages. However, the gas refrigeration cycle is one in which the working fluid (refrigerant) remains as gas throughout the cycle, such as Brayton refrigeration cycle and Stirling/Ericsson refrigeration cycle. The gas refrigeration cycle deviates from the reversed Carnot cycle/vapour compression refrigeration (VCR) cycle because the heat transfer to and from the gas cycle is not isothermal. In fact, the gas temperature varies considerably during heat transfer processes. Consequently, the gas refrigeration cycle has much lower coefficient of performance (COP) as compared to the VCR and reversed Carnot cycle. Also, gas refrigeration systems have a number of important applications over the vapour compression, vapour absorption, and hybrid refrigeration systems. Some of them are used to achieve very low temperature for many important applications, such as liquefaction of gases/air, aircraft cabin cooling, superconductivity-related R&D works, and other specialized applications. Among others, the Brayton refrigeration cycle is one of the important gas refrigeration cycles being used for space airconditioning applications with its unique application for aircraft cooling, liquefaction of gases, and cryogenic applications.

References

  1. Blanchard, C.H. (1980). Coefficient of performance for finite speed heat pump. J. Appl. Phys, 51(5), 2471–2472.ADSCrossRefGoogle Scholar
  2. Curzon, F.L. and Ahlborn, B. (1975). Efficiency of a Carnot engine at maximum power output. American Journal of Physics, 43, 22–24.ADSCrossRefGoogle Scholar
  3. Kodal, A., Sahin, B., Ekmekei, I. and Yilmaz, T. (2003). Thermoeconomic optimization for irreversible absorption refrigerators and heat pumps. Energy Convers. Mgmt, 44, 109–123.CrossRefGoogle Scholar
  4. Leff, H.S. and Teeters, W.D. (1978). EER, COP and second law efficiency for airconditioner. Am. J. Phys, 41(1), 19–22.ADSCrossRefGoogle Scholar
  5. Tyagi, S.K., Kaushik, S.C. and Salhotra, R. (2002). Ecological optimization and parametric study of irreversible Ericsson and Stirling heat engines. Journal of Phys D: Appl. Phys, 35, 2668–2675.ADSCrossRefGoogle Scholar
  6. Tyagi, S.K., Chen, J. and Hua, B. (2004a). Performance evaluation and parametric study of irreversible Carnot heat pump and refrigerator cycles. Proceedings of 3rd International Symposium on Heat Transfer Enhancement and Energy Conservation, Guangzhou, China.Google Scholar
  7. Tyagi, S.K., Chen, J. and Kaushik, S.C. (2004b). Thermoeconomic optimization and parametric study of an irreversible Stirling heat pump cycle. Int. J. of Thermal Sciences, 43, 105–112.CrossRefGoogle Scholar
  8. Tyagi, S.K., Zhou, Y. and Chen, J. (2004c). Optimum criteria on the performance of an irreversible Braysson heat engine based on the new thermoeconomic approach. Entropy—An Int. Journal, 6, 244–256.Google Scholar
  9. Tyagi, S.K., Chen, G.M., Wang, Q. and Kaushik, S.C. (2006a). A new thermoeconomic approach and parametric study of irreversible regenerative Brayton refrigeration cycle. Int. Journal of Refrigeration, 29, 1167–1174.CrossRefGoogle Scholar
  10. Tyagi, S.K., Chen, G.M., Wang, Q. and Kaushik, S.C. (2006b). Thermodynamic analysis and parametric study of an irreversible regenerative-intercooled-reheat Brayton cycle heat engine Int. Journal of Thermal Sciences, 45, 829–840.CrossRefGoogle Scholar

Copyright information

© Capital Publishing Company, New Delhi, India 2017

Authors and Affiliations

  • Shubhash C. Kaushik
    • 1
  • Sudhir K. Tyagi
    • 1
  • Pramod Kumar
    • 2
  1. 1.Centre for Energy StudiesIndian Institute of TechnologyNew DelhiIndia
  2. 2.Solid State Physics Laboratory (SSPL)New DelhiIndia

Personalised recommendations