Abstract
A high resolution Time Domain Reflectometry system has been designed in order to investigate the possibility of measuring with good accuracy the dielectric properties of high voltage cables insulator materials by means of Time-of-Flight measures. The system employs a dedicated Time-To-Digital Converter in order to achieve a time resolution of 90 ps. By exploiting averaging techniques the resolution has been further increased. Experimental results showed the possibility of measuring the dielectric constant with a resolution of 0.03%.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
BAUR: IRG 3000 Time Domain Reflectometer Datasheet. BAUR Corporation (2014)
Fluke Networks: TS-100 Cable Fault Finder Datasheet. Fluke Corporation (2006)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this paper
Cite this paper
Randazzo, G., Di Stefano, A., Costantino Giaconia, G. (2018). High Resolution Time Domain Reflectometry for Dielectric State Monitoring in High Voltage Cables. In: De Gloria, A. (eds) Applications in Electronics Pervading Industry, Environment and Society. ApplePies 2016. Lecture Notes in Electrical Engineering, vol 429. Springer, Cham. https://doi.org/10.1007/978-3-319-55071-8_13
Download citation
DOI: https://doi.org/10.1007/978-3-319-55071-8_13
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-55070-1
Online ISBN: 978-3-319-55071-8
eBook Packages: EngineeringEngineering (R0)