Skip to main content

Oc and CTX BioSensors: Characteristics and Validation

  • Chapter
  • First Online:
Point-of-Care Solution for Osteoporosis Management
  • 331 Accesses

Abstract

As mentioned in Chap. 3, while immunoassays have an extensive application in both clinic and research, the immunosensor concept is yet to be implemented in routine diagnostics [23, 24]. There are certain issues in this regard, the most important of which is the coupling chemistry of proteins on surfaces, which is critical for optimal functioning. In other words, the optimal orientation of Ab molecules on the surface is of great importance in selective and sensitive detection in a reproducible way without affecting its activity [25]. The relative lack of long-term stability of biological molecules is the most important limitation in commercializing biosensors.

Therefore, this chapter deals with the immobilization of two main BTMs (Oc and CTX) on the glass-based gold electrode fabricated as mentioned in Chap. 5 and coated with AuNPs. To our knowledge, a biosensor to assess serum levels of Oc has not been developed before. A stepwise protocol to develop these sensors is explained here.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  1. J. Brown, P.D. Delmas, L. Malaval, C. Edouard, M.C. Chapuy, P.J. Meunier, Serum bone gla-protein: a specific marker for bone formation in postmenopausal osteoporosis. Lancet 1, 1091–1093 (1984)

    Article  Google Scholar 

  2. K. Nimptsch, S. Hailer, S. Rohrmann, K. Gedrich, G. Wolfram, J. Linseisen, Determinants and correlates of serum undercarboxylated osteocalcin. Ann. Nutr. Metab. 51 (6), 563–570 (2007)

    Article  Google Scholar 

  3. S. Atalay, A. Elci, H. Kayadibi, C. Onder, N. Aka, Diagnostic utility of osteocalcin, undercarboxylated osteocalcin, and alkaline phosphatase for osteoporosis in premenopausal and postmenopausal women. Ann. Lab. Med. 32 (1), 23–30 (2012)

    Article  Google Scholar 

  4. P. Khashayar, H.A. Meybodi, G. Amoabediny, B. Larijani, Biochemical markers of bone turnover and their role in osteoporosis diagnosis: a narrative review. Recent Pat. Endocr. Metab. Immune Drug Discovery 9 (2), 79–89 (2015)

    Article  Google Scholar 

  5. V. Jagtap, J. Ganu, N. Nagane, BMD and serum intact osteocalcin in postmenopausal osteoporosis women. Ind. J. Clin. Biochem. 26 (1), 70–73 (2011)

    Article  Google Scholar 

  6. E. Chow, D. Hibberta, J. Gooding, Voltammetric detection of cadmium ions at glutathione-modified gold electrodes. Analyst 130, 831–837 (2005)

    Article  Google Scholar 

  7. M. Swartz, I. Krull, Handbook of Analytical Validation (CRC Press, Boca Raton, 2012)

    Google Scholar 

  8. G.L. Long, J.D. Winefordner, Linearization of electron capture detector response to strongly responding compounds. Anal. Chem. 55 (7), 713A–724A (1983)

    Google Scholar 

  9. J. Bartlett, C. Frost, Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables. Ultrasound Obstet. Gynecol. 31, 466–475 (2008)

    Article  Google Scholar 

  10. M. Mayer, J. yang, I. Gitlin, D.H. Gracias, G.M. Whitesides, Micropatterned agarose gels for stamping arrays of proteins and gradients of proteins. Proteomics 4, 2366–2376 (2004)

    Google Scholar 

  11. A. Bernard, E. Delamarche, H. Schmid, B. Michel, H. Bosshard, H. Biebuyck, Printing patterns of proteins. Langmuir 14, 2225 (1998)

    Article  Google Scholar 

  12. P. Garnero, The contribution of collagen crosslinks to bone strength. BoneKEy Rep. 1, 182 (2012)

    Article  Google Scholar 

  13. S. Vasikaran, R. Eastell, O. Bruyere, A. Foldes, P. Garnero, A. Griesmacher, M. McClung, H.A. Morris, S. Silverman, T. Trenti, D. Wahl, C. Cooper, J. Kanis, for the IOF-IFCC Bone Marker Standards Working Group, Markers of bone turnover for the prediction of fracture risk and monitoring of osteoporosis treatment: a need for international reference standards. Osteoporos. Int. 22, 391–420 (2011)

    Google Scholar 

  14. S. Chubb, Measurement of c-terminal telopeptide of type I collagen (CTX) in serum. Clin. Biochem. 45 (12), 928–935 (2012)

    Article  Google Scholar 

  15. S. Baim, P.D. Miller, Perspective: assessing the clinical utility of serum ctx in postmenopausal osteoporosis and its use in predicting risk of osteonecrosis of the jaw. J. Bone Miner. Res. 24, 561–574 (2009)

    Article  Google Scholar 

  16. M. Bonde, P. Garnero, C. Fledelius, P. Qvist, P. Delmas, C. Christiansen, Measurement of bone degradation products in serum using antibodies reactive with an isomerized form of an 8 amino acid sequence of the c-telopeptide of type I collagen. J. Bone Miner. Res. 12 (7), 1028–1034 (1997)

    Article  Google Scholar 

  17. C. Rosenquist, C. Fledelius, S. Christgau, B. Pedersen, M. Bonde, P. Qvist, C. Christiansen, Serum crosslaps one step ELISA. First application of monoclonal antibodies for measurement in serum of bone-related degradation products from c-terminal telopeptides of type I collagen. Clin. Chem. 44 (11), 2281–2289 (1998)

    Google Scholar 

  18. Y.-H. Yun, A. Bhattacharya, N.B. Watts, M.J. Schulz, A label-free electronic biosensor for detection of bone turnover markers. Sensors 9 (10), 7957–7969 (2009)

    Article  Google Scholar 

  19. M. Ramanathan, M. Patil, R. Epur, Y. Yun, V. Shanov, M. Schulz, W.R. Heineman, M. Datta, P. Kumta, Gold-coated carbon nanotube electrode arrays: immunosensors for impedimetric detection of bone biomarkers. Biosens. Bioelectron. 77, 580–588 (2016)

    Article  Google Scholar 

  20. A. Killard, B. Deasy, R. O’Kennedy, M. Smyth, Antibodies: production, functions and applications in biosensors. Trends Anal. Chem. 14 (6), 257–266 (1995)

    Article  Google Scholar 

  21. M. Fischer, Amine coupling through EDC/NHS: a practical approach. Methods Mol. Biol. 627, 55–73 (2010)

    Article  Google Scholar 

  22. M. Hormozi-Nezhada, E. Seyedhosseinia, E. Robatjazia, Spectrophotometric determination of glutathione and cysteine based on aggregation of colloidal gold nanoparticles. Sci. Iran. 19 (3), 958–963 (2012)

    Article  Google Scholar 

  23. T.R. Holford, F. Davis, S.P. Higson, Recent trends in anti- body based sensors. Biosens. Bioelectron. 34 (1), 12–24 (2012)

    Article  Google Scholar 

  24. K. Omidfar, F. Khorsand, M. Darziani Azizi, New analytical applications of gold nanoparticles as label in ab based sensors. Biosens. Bioelectron. 43, 336–347 (2013)

    Article  Google Scholar 

  25. E. Katchalski-Katzir, D. Kraemer, C. Eupergit, A carrier for immobilization of enzymes of industrial potential. J. Mol. Catalysis B Enzymatic 10, 157–176 (2000)

    Article  Google Scholar 

  26. F. Rusmini, Z. Zhong, J. Feijen, Protein immobilization strategies for protein biochips. Biomacromolecules 8, 1775 (2007)

    Article  Google Scholar 

  27. J. La Belle, A. Fairchild, U. Demirok, A. Verma, Method for fabrication and verification of conjugated nanoparticle-ab tuning elements for multiplexed electrochemical biosensors. Methods 61 (1), 39–51 (2013)

    Article  Google Scholar 

  28. W. Vastarella, L. Della Seta, A. Masci, J. Maly, M. De Leo, L. Maria Moretto, R. PIlloton, Biosensors based on gold nanoelectrode ensembles and screenprinted electrodes. Int. J. Environ. Anal. Chem. 87 (10–11), 701–714 (2007)

    Article  Google Scholar 

  29. P. Khashayar, G. Amoabediny, M. Hosseini, R. Verplancke, F. Razi, J. Vanfleteren, B. Larijani, An electrochemical biosensor based on AuNP-modified gold electrodes for selective determination of serum levels of osteocalcin. Sensors 17(11), 3367–3374 (2017)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this chapter

Cite this chapter

Khashayar, P. (2017). Oc and CTX BioSensors: Characteristics and Validation. In: Point-of-Care Solution for Osteoporosis Management. Springer, Cham. https://doi.org/10.1007/978-3-319-55053-4_6

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-55053-4_6

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-55052-7

  • Online ISBN: 978-3-319-55053-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics