Abstract
Tribocorrosion performance of medical grade AISI 316L stainless steel with and without surface modification has been studied during exposure to an electrolyte. Some of the samples investigated were surface modified by plasma nitriding (at both 400 and 550 °C), and others by a special arc physical vapor deposition to secure a thin layer of a diamond-like carbon (DLC) coating on the surface of the samples. XRD and SEM were used to characterize the homogeneity and microstructure of all samples. Potentiodynamic polarization measurement and tribocorrosion tests were performed multiple times on all groups of samples. It was established that surface treated SS 316L exhibited totally different passive behaviors, which consequently lead different tribocorrosion performance in the electrolyte. It was also established that the DLC coating performed as a solid lubricant in the ball-on-plate tests, and the resulting wear track after the tribocorrosion tests was almost negligible. On the other hand, the untreated and Nitriding 400 °C samples experienced wear accelerated corrosion due to their passive behavior. The results suggest that the DLC coated SS 316L have the best performance at the combined wear and corrosion environment, while the untreated and Nitriding 400 °C samples should be avoided to apply in biological tribocorrosion conditions.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Reference
S. Mischler, “Triboelectrochemical techniques and interpretation methods in tribocorrosion: A comparative evaluation,” Tribol. Int., vol. 41, no. 7, pp. 573–583, Jul. 2008.
N. Espallargas, R. E. Aune, C. Torres, N. Papageorgiou, and a. I. Muñoz, “Bulk metallic glasses (BMG) for biomedical applications—A tribocorrosion investigation of Zr55Cu30Ni5Al10 in simulated body fluid,” Wear, vol. 301, no. 1–2, pp. 271–279, Apr. 2013.
N. Espallargas and S. Mischler, “Tribocorrosion behaviour of overlay welded Ni–Cr 625 alloy in sulphuric and nitric acids: Electrochemical and chemical effects,” Tribol. Int., vol. 43, no. 7, pp. 1209–1217, Jul. 2010.
N. Espallargas and S. Mischler, “Dry wear and tribocorrosion mechanisms of pulsed plasma nitrided Ni–Cr alloy,” Wear, vol. 270, no. 7–8, pp. 464–471, Mar. 2011.
A. Bazzoni, S. Mischler, and N. Espallargas, “Tribocorrosion of Pulsed PlasmaNitrided CoCrMo Implant Alloy,” Tribol. Lett., vol. 49, no. 1, pp. 157–167, Oct. 2012.
M. Asgari, a. Barnoush, R. Johnsen, and R. Hoel, “Microstructural characterization of pulsed plasma nitrided 316L stainless steel,” Mater. Sci. Eng. A, vol. 529, pp. 425–434, Nov. 2011.
C. Valero Vidal and a. Igual Muñoz, “Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids,” Corros. Sci., vol. 50, no. 7, pp. 1954–1961, Jul. 2008.
B. Larisch, U. Brusky, and H.-J. Spies, “Plasma nitriding of stainless steels at low temperatures,” Surf. Coatings Technol., vol. 116–119, pp. 205–211, Sep. 1999.
M. Azzi, M. Paquette, J. a. Szpunar, J. E. Klemberg-Sapieha, and L. Martinu, “Tribocorrosion behaviour of DLC-coated 316L stainless steel,” Wear, vol. 267, no. 5–8, pp. 860–866, Jun. 2009.
L. Wang, J. F. Su, and X. Nie, “Corrosion and tribological properties and impact fatigue behaviors of TiN- and DLC-coated stainless steels in a simulated body fluid environment,” Surf. Coatings Technol., vol. 205, no. 5, pp. 1599–1605, Nov. 2010.
M. Azzi, P. Amirault, M. Paquette, J. E. Klemberg-Sapieha, and L. Martinu, “Corrosion performance and mechanical stability of 316L/DLC coating system: Role of interlayers,” Surf. Coatings Technol., vol. 204, no. 24, pp. 3986–3994, Sep. 2010.
R. Hauert, “A review of modified DLC coatings for biological applications,” Diam. Relat. Mater., vol. 12, no. 3–7, pp. 583–589, Mar. 2003.
G. Dearnaley and J. H. Arps, “Biomedical applications of diamond-like carbon (DLC) coatings: A review,” Surf. Coatings Technol., vol. 200, no. 7, pp. 2518–2524, Dec. 2005.
C. Li and T. Bell, “Corrosion properties of active screen plasma nitrided 316 austenitic stainless steel,” Corros. Sci., vol. 46, no. 6, pp. 1527–1547, Jun. 2004.
M. Martinesi, M. Stio, C. Treves, and F. Borgioli, “Biocompatibility studies of low temperature nitrided and collagen-I coated AISI 316L austenitic stainless steel,” J. Mater. Sci. Mater. Med., vol. 24, no. 6, pp. 1501–13, Jun. 2013.
M. Asgari, A. Barnoush, R. Johnsen, and R. Hoel, “Small-scale structural and mechanical characterization of the nitrided layer in martensitic steel,” Tribol. Int., vol. 61, no. 7465, pp. 109–115, May 2013.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2015 TMS (The Minerals, Metals & Materials Society)
About this paper
Cite this paper
Zhao, G., Espallargas, N., Aune, R.E. (2015). Tribocorrosion Studies on Surface Modified Medical Grade Stainless Steel. In: TMS 2015 144th Annual Meeting & Exhibition. Springer, Cham. https://doi.org/10.1007/978-3-319-48127-2_66
Download citation
DOI: https://doi.org/10.1007/978-3-319-48127-2_66
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-48608-6
Online ISBN: 978-3-319-48127-2
eBook Packages: Chemistry and Materials ScienceChemistry and Material Science (R0)