Advertisement

Clinical Evaluation of a Socket-Ready Naturally Controlled Multichannel Upper Limb Prosthetic System

  • Ivan VujaklijaEmail author
  • Sebastian Amsuess
  • Aidan D. Roche
  • Dario Farina
  • Oskar C. Aszmann
Conference paper
Part of the Biosystems & Biorobotics book series (BIOSYSROB, volume 16)

Abstract

Research conducted over the last decades indicates a necessity of having larger number of EMG sensors in order to extract sufficient information needed for natural control of upper limb prosthetics. Various studies have addressed this issue, though clinical transition and evaluation of such systems on a larger pool of patients is still missing. We propose a specifically designed system which allows users to perform clinically relevant tests in an unobstructed way while handling dexterous prosthesis. Eight electrodes were embedded into customized sockets along with the controllers driving an algorithm recently tested in laboratory conditions that allows simultaneous manipulation of four out of seven prosthetic functions. The fully self-contained system was evaluated on seven amputees conducting the Southampton Hand Assessment Procedure. The scores achieved were compared to those obtained using their own commercial devices. The study shows the necessary steps to validate novel control algorithms in a clinically meaningful context.

Keywords

Linear Discriminant Analysis Wrist Flexor Prosthetic Hand Limb Prosthetic Linear Discriminant Analysis Classifier 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Notes

Acknowledgments

The authors would like to extend their gratitude to Mr. Hans Opel and his team of prosthetists at Otto Bock Healthcare Products GmbH for manufacturing and fitting all the patients with custom made sockets.

References

  1. 1.
    Hudgins, B., Parker, P., Scott, R.N.: A new strategy for multifunction myoelectric control. IEEE Trans. Biomed. Eng. 40(1), 82–94 (1993)CrossRefGoogle Scholar
  2. 2.
    Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., Farina, D.: Is accurate mapping of EMG signals on kinematics needed for precise online myoelectric control? IEEE Trans. Neural Syst. Rehabil. Eng. 22(3), 549–558 (2014)CrossRefGoogle Scholar
  3. 3.
    Scott, R.N., Parker, P.A.: Myoelectric prostheses: state of the art. J. Med. Eng. Technol. 12(4), 143–151 (1988)CrossRefGoogle Scholar
  4. 4.
    Oskoei, M.A., Hu, H.: Myoelectric control systems-a survey. Biomed. Signal Process. Control 2(4), 275–294 (2007)CrossRefGoogle Scholar
  5. 5.
    Hargrove, L., Englehart, K., Hudgins, B.: A training strategy to reduce classification degradation due to electrode displacements in pattern recognition based myoelectric control. Biomed. Signal Process. Control 3(2), 175–180 (2008)CrossRefGoogle Scholar
  6. 6.
    Amsuess, S., Vujaklija, I., Gobel, P., Roche, A., Graimann, B., Aszmann, O., Farina, D.: Context-dependent upper limb prosthesis control for natural and robust use. IEEE Trans. Neural Syst. Rehabil. Eng., 1 (2015)Google Scholar
  7. 7.
    Light, C.M., Chappell, P.H., Kyberd, P.J.: Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: normative data, reliability, and validity. Arch. Phys. Med. Rehabil. 83(6), 776–783 (2002)CrossRefGoogle Scholar
  8. 8.
    Roche, A.D., Vujaklija, I., Amsuess, S., Sturma, A., Göbel, P., Farina, D., Aszmann, O.C.: Structured rehabilitation training for improved multifunctional prosthetic control : a case study. J. Vis. Exp. (2015)Google Scholar
  9. 9.
    Montagnani, F., Controzzi, M., Cipriani, C.: Exploiting arm posture synergies in activities of daily living to control the wrist rotation in upper limb prostheses: a feasibility study. In: Proceedings of Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, vol. 2015, pp. 2462–2465, November 2015Google Scholar

Copyright information

© Springer International Publishing AG 2017

Authors and Affiliations

  • Ivan Vujaklija
    • 1
    Email author
  • Sebastian Amsuess
    • 2
  • Aidan D. Roche
    • 3
  • Dario Farina
    • 1
  • Oskar C. Aszmann
    • 3
  1. 1.Institute of Neurorehabilitation Systems, University Medical Center GöttingenGöttingenGermany
  2. 2.Ottobock Healthcare Products GmbHViennaAustria
  3. 3.Christian Doppler Laboratory for Restoration of Extremity FunctionMedical University of ViennaViennaAustria

Personalised recommendations