Abstract
Bioelectric signals are often corrupted by noise. The most common form of noise is power-line interference and its harmonics. A convenient way for eliminating these unwanted components is to use a single or multiple notch filters. One of the problems about this approach is the effect of transient response of the filter at the beginning of its output in short time measurements. In this work, three initialization methods, which can be used to reduce/overcome this problem are reviewed and their performance and computational complexity are evaluated using ECG as an example signal. These methods are projection initialization, pole radius-varying filtering and vector projection. Additionally, some implementation variations and memory usage considerations are discussed. Our study shows that, pole radius-varying method is computationally cheap but introduces longer transient than the others. On the other hand, vector projection provides a more accurate reconstruction of the signal in the transient part of the output but with a more expensive computation. There are also two drawbacks about vector projection. One is its computational complexity dependency to the sampling frequency of the signal and the other is the fact that it cannot provide the results in real-time.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Rangayyan R M, Reddy N P. Biomedical signal analysis: a case-study approach. New York, NY: Wiley-Interscience 2002.
Huhta James C, Webster J G. 60-Hz Interference in Electrocardiography Biomedical Engineering, IEEE Transactions. 1973;BME-20:91–101.
Pei S C, Tseng C C. IIR multiple notch filter design based on allpass filter Circuits and Systems II: Analog and Digital Signal Processing, IEEE Transactions. 1997;44:133–136.
Hendrikx T, Rosenqvist M, Wester P, Sandström H, Hörnsten R. Intermittent short ECG recording is more effective than 24-hour Holter ECG in detection of arrhythmias BMC cardiovascular disorders. 2014;14:41.
Vehkaoja A, Lekkala J. Wireless measurement band for EEG mismatch negativity registration in mobile activities in Proceedings of XVIII IMEKO world congress: metrology for a sustainable development(Rio de Janeiro, Brazil) 2006.
Burlage D W. An initialization technique for improved MTI performance in phased array radars Proceedings of the IEEE. 1972;60:1551–1552.
Dewald K, Bersier A, Gardella P J, Jacoby D. IIR filter transient suppression by signal shifting in Biennial Congress of Argentina (ARGENCON), 2014 IEEE:153–158 2014.
Al-Ahmad H, Ahmed K. A novel technique for initializing digital IIR filters with a finite number of samples at a single frequency Circuits and Systems II: Analog and Digital Signal Processing, IEEE Transactions. 1997;44:417–420.
Peterson R B, Atlas L E, Beach K W. A comparison of IIR initialization techniques for improved color Doppler wall filter performance in Ultrasonics Symposium, 1994. Proceedings., 1994 IEEE;3:1705–1708 1994.
Al-Ahmad H, El-Khazali R. A new technique for initializing digital IIR filters at two frequencies in Electronics, Circuits and Systems, 2003. ICECS 2003. Proceedings of the 2003 10th IEEE International Conference;1:64–67 2003.
Jeedella J, Ahamad H Al, Al-Mualla M E. Optimum bandwidth IIR notch filters with multiple frequency initializations in Electronics, Circuits and Systems, 2005. ICECS 2005. 12th IEEE International Conference:1–4 2005.
Chornoboy E S. Initialization for improved IIR filter performance Signal Processing, IEEE Transactions. 1992;40:543–550.
Pei S C, Tseng C C. Future of health insurance Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression. 1995;42:1128–1132.
Piskorowski J. Powerline interference removal from ECG signal using notch filter with non-zero initial conditions in Medical Measurements and Applications Proceedings (MeMeA), 2012 IEEE International Symposium:1-3 2012.
Piskorowski J. Powerline interference rejection from sEMG signal using notch filter with transient suppression in Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International:1447–1451 2012.
Piskorowski J. Digital Q -Varying Notch IIR Filter With Transient Suppression Instrumentation and Measurement, IEEE Transactions. 2010;59:866–872.
Moody G B, Mark R G. The impact of the MIT-BIH Arrhythmia Database Engineering in Medicine and Biology Magazine, IEEE. 2001;20:45–50.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Mahdiani, S., Jeyhani, V., Vehkaoja, A. (2016). A Review of Transient Suppression Methods of IIR Notch Filters Used for Power-Line Interference Rejection in ECG Measurement. In: Kyriacou, E., Christofides, S., Pattichis, C. (eds) XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016. IFMBE Proceedings, vol 57. Springer, Cham. https://doi.org/10.1007/978-3-319-32703-7_31
Download citation
DOI: https://doi.org/10.1007/978-3-319-32703-7_31
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-32701-3
Online ISBN: 978-3-319-32703-7
eBook Packages: EngineeringEngineering (R0)