Facial pacing ultimately aims at improving the quality of life of people suffering from unilateral facial paralysis. A device to study facial pacing is presented. It is able to measure electromyography signals from the healthy side of the face and simultaneously activate the corresponding muscles on the paralyzed side with electrical stimulation. Tests with healthy participants are ongoing and clinical studies are to be started soon. Four measurement and four stimulation channels of the device enable studying different electrode configurations and stimulation patterns for recognizing and reanimating symmetrical facial expressions in the future. Preliminary testing with ten healthy volunteers showed average partial activation threshold of 2.50 mA (± 0.47 mA) and 3.00 mA (± 0.67 mA) for orbicularis oculi and orbicularis oris muscles, respectively, and full eye closure threshold of 4.45 mA (± 0.69 mA).

The original version of this chapter was inadvertently published with an incorrect chapter pagination 647–652 and DOI 10.1007/978-3-319-32703-7_125. The page range and the DOI has been re-assigned. The correct page range is 653–658 and the DOI is 10.1007/978-3-319-32703-7_126. The erratum to this chapter is available at DOI: 10.1007/978-3-319-32703-7_260

An erratum to this chapter can be found at http://dx.doi.org/10.1007/978-3-319-32703-7_260

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Rumsey N, Clarke A, White P, Wyn-Williams M, Garlick W (2004) Altered body image: appearance-related concerns of people with visible disfigurement. J Adv Nurs 48(5):443–453

    Google Scholar 

  2. Coulson SE, O’dwyer NJ, Adams RD, Croxson GR (2004) Expression of emotion and quality of life after facial nerve paralysis. Otol Neurotol 25(6):1014–1019 DOI 10.1097/00129492-200411000-00026

    Google Scholar 

  3. Frigerio A, Cavallari P (2012) A closed-loop stimulation system supplemented with motoneurone dynamic sensitivity replicates natural eye blinks. Otolaryngol Head Neck Surg 146(2):230–233 DOI 10.1177/0194599811427255

    Google Scholar 

  4. Sarasola Sanz A, Frigeni M, Cavallari P, Frigerio A, Pedrocchi A, Ferrante S (2013) Design of a Contralaterally Triggered Neuroprosthesis for the Paralyzed Eyelid: Surface EMG Mapping of the Orbicularis Oculi Muscle for Real-time Eye Blink Detection. Proceedings of the 18th IFESS Conference, San Sebastian, Spain, 2013, pp 49–52

    Google Scholar 

  5. Frigerio A, Brenna S, Cavallari P (2013) Surface electromyography recording of spontaneous eyeblinks: applications in neuroprosthetics. Otolaryngol Head Neck Surg 2013 148(2):209–214. DOI 10.1177/0194599812469352

    Google Scholar 

  6. Frigerio A, Cavallari P, Frigeni M, Pedrocchi A, Sarasola A, Ferrante S (2014) Surface electromyographic mapping of the orbicularis oculi muscle for real-time blink detection. JAMA Facial Plast Surg 16(5):335–342 DOI 10.1001/jamafacial.2014.283

    Google Scholar 

  7. Yi X, Jia J, Deng S et al. (2013) A Blink Restoration System With Contralateral EMG Triggered Stimulation and Real-Time Artifact Blanking, in Biomedical Circuits and Systems, IEEE Transactions on, 7(2):140–148 DOI: 10.1109/TBCAS.2013.2255051

    Google Scholar 

  8. Frigerio A, Hadlock TA, Murray EH, Heaton JT (2014) Infrared-based blink-detecting glasses for facial pacing: toward a bionic blink, JAMA Facial Plast Surg 16(3):211–218 DOI 10.1001/jamafacial.2014.1

    Google Scholar 

  9. Frigerio A, Heaton JT, Cavallari P, Knox C, Hohman MH, Hadlock TA (2015) Electrical Stimulation of Eye Blink in Individuals with Acute Facial Palsy: Progress toward a Bionic Blink. Plast Reconstr Surg 136(4):515e–523e DOI 10.1097/PRS.0000000000001639

    Google Scholar 

  10. Marcelli E, Cavallari P, Frigerio A, Colletti G, Biglioli F, Fanti R, Plicchi G, Cercenelli L (2013) A new gyro-based method for quantifying eyelid motion. Int J Artif Organs 36(3):195–202 DOI 10.5301/ijao.5000178

    Google Scholar 

  11. Kantor G, Alon G, Ho HS (1994) The effects of selected stimulus waveforms on pulse and phase characteristics at sensory and motor thresholds. Phys Ther 74(10):951–962.

    Google Scholar 

  12. Reed B (1997) The Physiology of Neuromuscular Electrical Stimulation. Pediatr Phys Ther 9:96–102

    Google Scholar 

  13. Johnson MI (2002) Transcutaneous Electrical Nerve Stimulation. In: Kitchen, S (ed.) 2002, Electrotherapy: Evidence Based Practice. 11 edn, Churchill Livingstone (Elsevier Health Sciences), London

    Google Scholar 

  14. Delitto A, Rose SJ. (1986) Comparative comfort of three waveforms used in electrically eliciting quadriceps femoris muscle contractions Phys Ther 66(11):1704–1707

    Google Scholar 

  15. Peckham PH, Knutson JS (2005) Functional electrical stimulation for neuromuscular applications. Annu Rev Biomed Eng 7:327–360

    Google Scholar 

  16. Shafshak TS (2006) The treatment of facial palsy from the point of view of physical and rehabilitation medicine. Eura Medicophys 42(1):41–47

    Google Scholar 

  17. Rodriguez MR, Mendez E (1998) Quantal processing of visual information in the brain. Neuroscience 84(3):641–644 DOI 10.1016/S0306-4522(97)00679-9

    Google Scholar 

  18. Kim SW, Heller ES, Hohman MH, Hadlock TA, Heaton JT (2013) Detection and perceptual impact of side-to-side facial movement asymmetry. JAMA Facial Plast Surg 15(6):411–416 DOI 10.1001/jamafacial.2013.1227

    Google Scholar 

  19. Hohman MH, Kim SW, Heller ES, Frigerio A, Heaton JT, Hadlock TA (2014) Determining the threshold for asymmetry detection in facial expressions. Laryngoscope 124(4):860–865. DOI 10.1002/lary.24331

    Google Scholar 

  20. Sachs NA, Chang EL, Weiland JD (2006) Contralateral EMG-triggered electrical stimulation of the eyelid. 11th Annual Conference of the International Functional Electrical Stimulation Society, Zao, Japan, 2006, pp 286–288

    Google Scholar 

  21. Chen K, Chen T-C, Cockerham K, Liu W (2009) Closed-loop eyelid reanimation system with real-time blink detection and electrochemical stimulation for facial nerve paralysis. IEEE International Symposium on Circuits and Systems (ISCAS),Taipei, Taiwan, 2009, pp 549–552 DOI 10.1109/ISCAS.2009.5117807

    Google Scholar 

  22. Meza-Cuevas MA, Gummenscheimer A, Schroeder D, and Krautschneider, WH (2012) Portable Neuromuscular Electrical Stimulator. ICT.OPEN, Rotterdam, Netherlands, 2012, 4 pages

    Google Scholar 

  23. Cao J, Lu B, Li L, Tong K, Wang W (2008) Implanted FNS system in closed-circle may become a way for the restoration of eye blinking and closing function for facial paralysis patient. Med Hypotheses 70(5):1068–1069 DOI 10.1016/j.mehy.2007.11.008

    Google Scholar 

  24. Cao J, Li L, Tong K, Lu B, Chu C, Li H, Yang B, Wang W (2009) FNS therapy for the functional restoration of the paralysed eyelid. J Plast Reconstr Aesthet Surg 62(12):e622–624 DOI 10.1016/j.bjps.2008.10.018

    Google Scholar 

  25. McDonnall D, Askin R, Smith C, Guillory KS (2013) Verification and validation of an electrode array for a blink prosthesis for facial paralysis patients. 6th International IEEE/EMBS Conference on Neural Engineering (NER), San Diego, CA, USA, 2013, pp 1167–1170 DOI 10.1109/NER.2013.6696146

    Google Scholar 

  26. Council directive 93/42/EEC (1993) Official Journal of the European Communities 12/07/1993:1-43

    Google Scholar 

  27. Fridlund, AJ, Cacioppo, JT (1986) Guidelines for human electromyographic research. Psychophysiology, 23(5):567–589

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ville Rantanen .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this paper

Cite this paper

Rantanen, V. et al. (2016). Prosthetic Pacing Device for Unilateral Facial Paralysis. In: Kyriacou, E., Christofides, S., Pattichis, C. (eds) XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016. IFMBE Proceedings, vol 57. Springer, Cham. https://doi.org/10.1007/978-3-319-32703-7_126

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-32703-7_126

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-32701-3

  • Online ISBN: 978-3-319-32703-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics