Abstract
The principle of operation and metrological model of the Ukrainian primary standard of electrolytic conductivity (EC) is presented. The equations for calculating the cell constant and the budget of unknown errors for estimation of the uncertainty B-type are given. Strategies: how to minimize components of this uncertainty are proposed and obtained results, verified by Key Comparisons, are given.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Shreiner, R.H., Pratt, K.W.: Standard Reference Materials: Primary Standards and Standard Reference Materials for Electrolytic Conductivity. NIST Special Publication, pp. 260–142, (2004)
Mariassy, M., Pratt, K.W., Spitzer, P.: Major applications of electro-chemical techniques at National Metrology Institutes. Metrologia 46, 199–213 (2009)
Brinkmann, F., et al.: Primary methods for the measurement of electrolytic conductivity. Accred. Qual. Assur. 346–353 (2003) doi:10.1007/s00769-003-0645-5
Hlukhenky, A.I., Miкhal, A.A.: Analysis of circular conductor impedance component within AC measurement. Tehnichna Elektrodynamika 1, 15–22 (2010, in Russian). Available online at http://www.techned.org.ua
Hlukhenky, A.I., Miкhal, A.A.: Error estimation of standard conductometric cell conditional on non-equipotentiality of electrode fase. Tehnichna Elektrodynamika 1, 76-82 (2011, in Russian). Available online at http://www.techned.org.ua
Gavrylkin, V.G., Glukhenkiy, A.I., Miкhal, A.A.: An analysis of the error when determining the constant of the primary standard conductometric cell. Meas. Tech. 56(8), 935–941 (2013)
Mikhal A.A., Warsza Z.L.: Influence of geometric uncertainties on the accuracy of calculated constant of the primary conductivity cell. In: CD Proceedings of 11th TC 24 IMEKO International Symposium ISMQC on Measurement and Quality Control, p. 87. Cracow-Kielce, Poland (2013)
Mikhal, A.A., Warsza, Z.L.: Geometric part of uncertainties in the calculation constant of the primary four electrode conductivity cell. ACTA IMEKO 4(2), 18–21 (2015)
Jensen, H.D.: Final report of Key Comparison CCQM-K36. Aug 15 2006, available at http://kcdb.bipm.org/AppendixB/appbresults/ccqm-k36/ccqm-k36_final_report.pdf
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Mikhal, A.A., Warsza, Z.L., Gavrylkin, V.G. (2016). Correction of the Influence of not Ideal Geometric Profile on the Constant of Primary Cell. In: Awrejcewicz, J., Kaliński, K., Szewczyk, R., Kaliczyńska, M. (eds) Mechatronics: Ideas, Challenges, Solutions and Applications. Advances in Intelligent Systems and Computing, vol 414. Springer, Cham. https://doi.org/10.1007/978-3-319-26886-6_15
Download citation
DOI: https://doi.org/10.1007/978-3-319-26886-6_15
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-26885-9
Online ISBN: 978-3-319-26886-6
eBook Packages: EngineeringEngineering (R0)