Other Air Delivery Schemes

  • Chapter
  • First Online:
Air Flow Management in Raised Floor Data Centers

Part of the book series: SpringerBriefs in Applied Sciences and Technology ((BRIEFSTHERMAL))

  • 581 Accesses

Abstract

While the raised floor HACA layout with peripheral CRAC units discussed in the previous chapters is the most commonly employed one in most legacy, as well as many recently constructed data centers, a growing number of new facilities are employing alternate air delivery approaches. In this chapter we discuss some of these. Figure 5.1 provides a summary of several possible approaches used in data center thermal management. All of these assume local heat rejection from the IT equipment to the data center room air (Evans 2012). The hot room air then transmits heat via multiple possible coolants or interfaces outside the IT facility envelope. An array of options also exists for the ultimate heat rejection to the environment from the intermediate heat transmission devices that transport the heat to outside the data center envelope.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Dunlap, K., & Rasmussen, N. (2006). The advantages of row and rack-oriented cooling architectures for data centers (APC White Paper #130).

    Google Scholar 

  • Evans, T. (2012). The different technologies for cooling air (White Paper 59, Rev. 2). Schneider Electric.

    Google Scholar 

  • Rasmussen, N. (2014). Raised floor vs hard floor for data center applications (White Paper 19, Rev. 3).

    Google Scholar 

  • Sasser, J. (2015). A look at data center cooling technologies in design. Uptime Institute. Retrieved August 30, 2015, from https://journal.uptimeinstitute.com/a-look-at-data-center-cooling-technologies/

  • Schmidt, R., Cruz, E., & Iyengar, M. (2005). Challenge of data center thermal management. IBM Journal of Research and Development, 49(4/5), 709–723.

    Article  Google Scholar 

  • Shrivastava, S., Sammakia, B., Schmidt, R., & Iyengar, M. (2005). Comparative analysis of different data center airflow management configuration. In Paper IPACK2005-73234, San Francisco, July 17–22, 2005.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this chapter

Cite this chapter

Arghode, V.K., Joshi, Y. (2016). Other Air Delivery Schemes. In: Air Flow Management in Raised Floor Data Centers. SpringerBriefs in Applied Sciences and Technology(). Springer, Cham. https://doi.org/10.1007/978-3-319-25892-8_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-25892-8_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-25890-4

  • Online ISBN: 978-3-319-25892-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics