Advertisement

Active Bending Electric Endoscope Using Shape Memory Alloy Wires

  • T. Kobayashi
  • T. Matsunaga
  • Y. Haga
Conference paper
Part of the Mechanisms and Machine Science book series (Mechan. Machine Science, volume 38)

Abstract

The bending mechanism of a conventional endoscope operates by drawing wires from outside the human body. The shaft structure of endoscopes is relatively complex to avoid buckling by the tensile force of the wire. Therefore, it is difficult to make a conventional endoscope. In this study, an active bending electric endoscope was developed using SMA (shape memory alloy) wires. The SMA wires are driven by Joule heat generated by electric current. As a result, the shaft structure of the active bending mechanism is simplified compared to the conventional endoscope. The active bending mechanism using SMA wires simplifies inspection inside the human body. This device consists of a commercial CMOS imager, three LEDs and a shaft structure. It is capable of multidirectional bending with a curvature radius of approximately 40 mm at 300 mA. The active bending mechanism using SMA wires would be suitable for construction of a disposable endoscope.

Keywords

SMA wire Endoscope Active bending mechanism CMOS imager 

References

  1. 1.
    Ueda Y (2005) Endo-scope systems. J Reliab Eng Assoc Japan 22(4):280–287 (in Japanese)Google Scholar
  2. 2.
    Ikuta K, Tsukamoto M, Hirose S (1987) Development of shape memory alloy actuator. Characteristics measurements of the alloy and development of an active endoscope: Characteristics measurements of the alloy and development of and active endoscope. Rob Soc Japan 5(2):87–101 (in Japanese)Google Scholar
  3. 3.
    Haga Y, Esashi M (2000) Small diameter active catheter using shape memory alloy coils. IEEE J Trans Sens Micromach 120(11):509–514CrossRefGoogle Scholar
  4. 4.
    Mineta T, Mitsui T, Watanabe Y, Kobayashi S, Haga Y, Esashi M (2001) Batch fabricated flat meandering shape memory alloy actuator for active catheter. Sens Actuators A 88:112–120CrossRefGoogle Scholar
  5. 5.
    Ohta R (2001) Results of R&D on catheter-type micromachine. In: Proceedings of 2001 international symposium on micromechatronics and human science, pp 5–12Google Scholar
  6. 6.
    Fukuda T, Guo S, Arai F, Kosuge K, Negoro M (1994) A study on active catheter system: 1st report, structure, experimental results and characteristic evaluation of multiunits using SMA active catheter with multi D. O. F. Trans JSME 60(573):1727–1734 (in Japanese)Google Scholar
  7. 7.
    Makishi W, Ikeda M, Esashi M, Matsunaga T, Haga Y (2011) Development of active bending electric endoscope using shape memory alloy for disposable and thin endoscope. Trans Inst Electr Eng Japan 131(3):102–110 (in Japanese)Google Scholar
  8. 8.
    Makishi W, Matsunaga T, Esashi M, Haga Y (2007) Active bending electric endoscope using shape memory alloy coil actuators. Trans Inst Electr Eng Japan 127(2):75–81 (in Japanese)Google Scholar
  9. 9.
    Takizawa H, Tosaka H, Ohta R, Kaneko S, Ueda Y (1999) Development of a Microfine active bending catheter equipped with MIF tactile sensors. In: Proceedings of IEEE MEMS’99, pp 412–417Google Scholar
  10. 10.
    Homma D, Uemura S, Nakazawa F (2007) Functional anisotropic shape memory alloy fiber and differential servo actuator. In: Proceedings of the international conference on shape memory and superelastic technologies, pp 463–472Google Scholar

Copyright information

© Springer International Publishing Switzerland 2016

Authors and Affiliations

  1. 1.Graduate School of EngineeringTohoku UniversitySendaiJapan
  2. 2.Micro System Integration CenterTohoku UniversitySendaiJapan
  3. 3.Graduate School of Biomedical EngineeringTohoku UniversitySendaiJapan

Personalised recommendations