Design of chilled water plants has very large impact on building energy use and energy operating cost. The chapter proposes procedures and analysis techniques for energy efficiency design of chilled water plants. The approach that leads to optimal design variables can achieve a significant saving in cooling cost. The optimal variables include piping sizing, chilled water temperature difference, and chilled water supply temperature. The objective function is the total cooling energy cost. The proposed design method depends on detailed cooling load analysis, head and energy calculations, and optimization solver. The pump head calculations including piping, all fittings, valves, and devices are achieved by using the Darcy–Weisbach Equation and given flow parameters. The energy calculations are done by using generic chiller, fan, and pump models. The method is tested on an existing office two-storey building with a packaged air-cooled chiller. A whole building energy simulation model is used to generate the hourly cooling loads, and then the optimal design variables are found to minimize the total energy cost. The testing results show this approach will achieve better results than rules-of-thumb or traditional design procedures. The cooling energy saving could be up to 10 % depending on particular projects.
Keywords
- Chilled water plants
- Optimization
- Design
- Commercial buildings
- Energy conservation
This is a preview of subscription content, access via your institution.
Buying options








References
ASHRAE Standard 90.1 (2013). Energy standard for buildings except low-rise residential buildings (90.1 I-P ed.). Atlanta, GA: ASHRAE.
Duda, S. W. (2012). Easy to use methods for multi-chiller plant energy and cost evaluation. ASHRAE Journal, 118, 1–8.
Durkin, T. H. (2005). Evolving design of chilled water plant. ASHRAE Journal, 47, 40–50.
Hydeman, M., & Zhou, G. (2007). Optimizing chilled water plant control. ASHRAE Journal, 49, 45–54.
Nassif, N., Hall, C., & Freeland, D. (2014). Optimal design and control of ice thermal storage system for a typical chilled water plant. ASHRAE Transactions, 120(1).
Nassif, N., Kajl, S., & Sabourin, R. (2005). Optimization of HVAC control system strategy using two-objective genetic algorithm. HVAC&R Research, 11(3), 459–486.
Taylor, S. T. (2011). Optimizing design & control of chilled water part 3: Pipe sizing and optimizing ΔT. ASHRAE Journal, 3, 22–34.
Taylor, S. T., & McGuire, M. (2008). Sizing pipe using life-cycle costs. ASHRAE Journal, 1, 24–32.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Freeland, D., Hall, C., Nassif, N. (2016). Optimizing the Design of Chilled Water Plants in Large Commercial Buildings. In: Uzochukwu, G., Schimmel, K., Kabadi, V., Chang, SY., Pinder, T., Ibrahim, S. (eds) Proceedings of the 2013 National Conference on Advances in Environmental Science and Technology. Springer, Cham. https://doi.org/10.1007/978-3-319-19923-8_19
Download citation
DOI: https://doi.org/10.1007/978-3-319-19923-8_19
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-19922-1
Online ISBN: 978-3-319-19923-8
eBook Packages: Earth and Environmental ScienceEarth and Environmental Science (R0)