Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 49))

Abstract

Dental implants are widely used clinically and have allowed considerable progresses in oral and maxillofacial surgery. However, implant failures, which may have dramatic consequences, still occur and remain difficult to anticipate. Accurate measurements of implants biomechanical stability are of interest since they could be used to improve the surgical strategy by adapting the choice of the healing period to each patient. Empirical methods based on palpation are still used by dental surgeons to determine when the implant should be loaded because it remains difficult to monitor bone healing in vivo. The objective of this study is to investigate the potentiality of a quantitative ultrasound method to assess the biomechanical stability of a dental implant in vitro. A 10 MHz contact transducer is located at the implant extremity. For each ultrasound measurement, a quantitative indicator I is derived based on the time variation of the amplitude of the rf signal. Ten implants are initially completely inserted in the proximal part of a bovine humeral bone sample. The 10 MHz ultrasonic response of the implants is then measured and an indicator I is derived based on the amplitude of the rf signal obtained. Then, the implants are unscrewed by 2π radians and the measurement is realized again. The procedure is repeated and the indicator I is derived after each rotation of the implants. Analysis of variance (ANOVA) (p<10− 5) tests revealed a significant effect of the amount of bone in contact with the implant on the distribution of the values of I. The results show the feasibility of QUS techniques to assess implant primary stability in vitro. This study paves the way for the development of a new biomechanical approach in oral implantology. This work will be continued in the framework of a Franco-Argentinian common laboratory (CNRS – CONICET) currently under evaluation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Vayron, R., Haiat, G. (2015). Assessment of the Biomechanical Properties of the Interface Surrounding a Dental Implant: An In Vitro Approach. In: Braidot, A., Hadad, A. (eds) VI Latin American Congress on Biomedical Engineering CLAIB 2014, Paraná, Argentina 29, 30 & 31 October 2014. IFMBE Proceedings, vol 49. Springer, Cham. https://doi.org/10.1007/978-3-319-13117-7_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-13117-7_2

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-13116-0

  • Online ISBN: 978-3-319-13117-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics