Abstract

The integration of grids of electrodes, US imaging and 3D kinematic can allow investigating how muscle architectural changes influence surface EMGs: this innovative approach can provide novel spatio-temporal information regarding electromechanical function of muscle, relevant both for improving basic knowledge and for clinical applications. The aims of the present study were i) to verify whether movements of the US probe lead to artefacts in surface EMGs detected with a grid of electrodes transparent to US; ii) to analyse how much muscle architectural changes, induced by changes in joint positions, can influence the amplitude distribution of surface EMGs. A young healthy participant performed contractions of the right tibialis anterior (TA) at two different ankle positions: A) neutral and B) full plantarflexion. While provided with EMG visual feedback, the participant was asked to recruit a single motor unit: contractions lasted  50 s. Surface EMGs, kinematic data and ultrasound images were acquired. The spatial distribution of the root mean square amplitude of motor unit action potentials was assessed from collected EMGs. Ankle angles were obtained from 3D kinematics. Muscle volume was obtained through the segmentation of US images reconstructed in 3D space: width and thickness variations between the two positions were measured.

Movements of the US probe over the grid of electrodes did not result in artefacts in the surface EMGs. Results indicate a marked effect of TA architecture on the amplitude distribution of action potentials of a single TA motor unit. When moving the foot from plantarflexion to neutral position, TA width increased of 11.6%. Interestingly, a corresponding increase in the RMS spatial distribution was observed for the ankle neutral position. Presuming the same motor unit was recruited for both ankle positions, the changes in EMG amplitude reported here were predominantly due to TA architectural changes.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Bisi, M.C., Botter, A., Stagni, R., Vieira, T. (2015). Integration of Surface EMG, US Imaging and 3D Kinematic: New Frontiers for Muscle Function Investigation. In: Lacković, I., Vasic, D. (eds) 6th European Conference of the International Federation for Medical and Biological Engineering. IFMBE Proceedings, vol 45. Springer, Cham. https://doi.org/10.1007/978-3-319-11128-5_89

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-11128-5_89

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-11127-8

  • Online ISBN: 978-3-319-11128-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics