Abstract
Quality control (QC) procedures for digital breast tomosynthesis (DBT) systems are a crucial part of the acceptance of a new modality. In contrast to the situation in the US, the European approach is to provide a device independent protocol with limiting values that should be applied to all systems. A European QC protocol that deals with this challenge is being developed and is currently work-in-progress. In this paper four specific QC tests for DBT, which have reached an (almost) final stage, are presented: reproducibility, system projection MTF, z-resolution and missed tissue at the top and bottom of the reconstructed volume. The proposed tests have been evaluated on several DBT systems. The encouraging results show that these tests will form an appropriate and necessary part of QC procedures for DBT.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Van Engen, R.E., Young, K.C., Bosmans, H., Thijssen, M.: European protocol for the quality control of the physical and technical aspects of mammography screening. Chapter 2b: Digital mammography. In: Perry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., von Karsa, L. (eds.) European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis, 4th edn., pp. 105–165. European Commission, Office for Official Publications of the European Communities, Luxembourg (2006)
Van Engen, R.E., Bosmans, H., Dance, D.R., Heid, P., Lazzari, B., Marshall, N., Schopphoven, S., Thijssen, M., Young, K.C.: Digital mammography update. European protocol for the quality control of the physical and technical aspects of mammography Screening S1, Part 1: Acceptance and constancy testing. In: Perry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., von Karsa, L. (eds.) European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis, 4th edn., pp. 1–54. Office for Official Publications of the European Communities, Luxembourg (2013)
Van Engen, R.E., Bosmans, H., Bouwman, R., Dance, D.R., Heid, P., Lazzari, B., Marshall, N.W., Schopphoven, S., Strudley, C., Thijssen, M.A.O., Young, K.C.: Protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, draft version 0.15, EUREF (2014), can be downloaded from www.euref.org
Dance, D.R., Young, K.C., van Engen, R.E.: Estimation of mean glandular dose for breast tomosynthesis: Factors for use with the UK, European and IAEA breast dosimetry protocols. Phys. Med. Biol. 56, 453–471 (2011)
Marshall, N.W., Bosmans, H.: Measurements of system sharpness for two digital breast tomosynthesis systems. Phys. Med. Biol. 57(22), 7629–7650 (2012)
Bouwman, R., Visser, R., Young, K., Dance, D., Lazzari, B., van der Burght, R., Heid, P., van Engen, R.: Daily quality control for breast tomosynthesis. In: Hsieh, J., Samei, E. (eds.) Medical Imaging 2010: The Physics of Medical Imaging (2010)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
van Engen, R.E. et al. (2014). A European Protocol for Technical Quality Control of Breast Tomosynthesis Systems. In: Fujita, H., Hara, T., Muramatsu, C. (eds) Breast Imaging. IWDM 2014. Lecture Notes in Computer Science, vol 8539. Springer, Cham. https://doi.org/10.1007/978-3-319-07887-8_63
Download citation
DOI: https://doi.org/10.1007/978-3-319-07887-8_63
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-07886-1
Online ISBN: 978-3-319-07887-8
eBook Packages: Computer ScienceComputer Science (R0)