Skip to main content

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 314))

  • 831 Accesses

Abstract

In the chapter there is presented general information on physical nature of network-to-ground insulation. Sense of “insulation equivalent resistance” parameter is explained. A method of insulation resistances-to-ground of single phases and insulation equivalent resistance determination is presented for de-energized AC IT systems. Procedures of insulation equivalent resistance and total capacitance determination in live networks are described. Detailed description of few methods of single phases insulation parameters (i.e. resistances and capacitances) determination in both single- and three-phase systems is given. Several unconventional methods of insulation parameters measurement are presented. Attention is paid to ways of ground fault, ground leakage and possible electric shock currents analytical evaluation and practical measurement. Influence of insulation parameters on these currents levels is discussed. Ground fault current compensation problems are dealt with.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ivanov E „Кaк пpaвильнo измepить coпpoтивлeниe изoляции элeктpoycтaнoвoк”, Novosti Elektrotechniki 2/2002 (in Russian) (“How to measure correctly insulation resistance?”)

    Google Scholar 

  2. Tsapenko E „Зaмыкaния нa зeмлю в ceтяx 6-35 кB”, Energoatomizdat 1986 (in Russian) (“Ground faults in 6–35 kV networks”)

    Google Scholar 

  3. Grawe W „Элeктpoпoжapoбeзoпacнocть выcoкoвoльтныx cyдoвыx элeктpoэнepгeтичecкиx cиcтeм”, Элмop 2003, (in Russian) (“Fire hazard in MV power systems at sea ships”)

    Google Scholar 

  4. Telzas Sp. z o.o. „Dokumentacja techniczno-ruchowa I-207-160. Układ kompensacji prądów pojemnościowych UKPP-2” (in Polish) („Technical documentation no. I-207-160 of UKPP-2 system of capacitive currents compensation”)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Piotr Olszowiec .

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this chapter

Cite this chapter

Olszowiec, P. (2014). Ground Insulation Measurement in AC IT Systems. In: Insulation Measurement and Supervision in Live AC and DC Unearthed Systems. Lecture Notes in Electrical Engineering, vol 314. Springer, Cham. https://doi.org/10.1007/978-3-319-07010-0_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-07010-0_2

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-07009-4

  • Online ISBN: 978-3-319-07010-0

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics