Abstract

The article presents the measurement and control system of plasmatron plasma reactor for utilization and recovery of metals from waste of printed circuit boards built in the Industrial Research Institute for Automation and Measurements in Poland. The plasma reactor is the key component of a test stand developed to conduct research on processing and recovery of metals from used electric and electronic equipment, especially from electronic printed circuit boards. The system allows, recording multiparametric measurements realized in real time and time-correlated, visualization of current values of measurements and states by means of SCADA software. Besides main functions of data acquisition and visualization, the system allows local and remote control of operation of reactor subsystems. Analysis of measurement chain is presented for the key parameter of reactor work, which is temperature measurement inside the reactor. Standard uncertainty of measurement of the temperature is evaluated and in this case equal to 5 °C.

Keywords

recycling electronic waste utilization plasma technology temperature measurements 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Huisman, J.: 2008 Review of Directive 2002/96 on WEEE, Final Report, United Nations University (2007)Google Scholar
  2. 2.
    Cobbing, M.: Toxic Tech: Not In Our Backyard (2008), Greenpeace.org
  3. 3.
    Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment (WEEE) (2003), http://ec.europa.eu/environment/waste/weee/index_en.htm, http://www.mg.gov.pl/English/ECONOMY/Industrial+Policy/ROHS+Directive, http://www.zipsee.pl/aktualnosci/112/zmiana-dyrektywy-weee.html
  4. 4.
    Szałatkiewicz, J., Szewczyk, R., Budny, E., Missala, T., Winiarski, W.: Construction aspects of plasma based technology for waste of electrical and electronic equipment (WEEE) management in urban areas. Procedia Engineering 57, 1100–1108 (2013)CrossRefGoogle Scholar
  5. 5.
    Szałatkiewicz, J.: Energy recovery from waste of printed circuit boards in plasmatron plasma reactor. Polish Journal of Environmental Studies 23(1) (2014)Google Scholar
  6. 6.
    Fotowicz, P.: Obliczanie niepewności rozszerzonej metodą analityczną opartą na splocie rozkładów wielkości wejściowych. Pomiary Automatyka Robotyka 1, 5 (2005) (in Polish)Google Scholar
  7. 7.
    Joint Committee for Guides in Metrology, Evaluation of measurement data — Guide to the expression of uncertainty in measurement. JCGM 100 (2008)Google Scholar
  8. 8.
    Arendarski, J.: Niepewność pomiarów, Oficyna Wydawnicza Politechniki Warszawskiej (2006) (in Polish)Google Scholar
  9. 9.
    Dorozhovets, M., Propozycje, Z.L.: Propozycje rozszerzenia metod wyznaczania niepewności wyniku pomiarów wg Przewodnika GUM (1) Uwzględnianie wpływu autokorelacji i nieadekwatności rozkładu wyników obserwacji w niepewności typu A. Pomiary Automatyka Robotyka 11(1), 6–15 (2007) (in Polish)Google Scholar
  10. 10.
    Dorozhovets, M., Propozycje, Z.L.: rozszerzenia metod wyznaczania niepewności wyniku pomiarów wg Przewodnika GUM (2) Uściślenie metod obliczeń niepewności typu B. Pomiary Automatyka Robotyka 11(2), 45–52 (2007) (in Polish)Google Scholar

Copyright information

© Springer International Publishing Switzerland 2014

Authors and Affiliations

  • Jakub Szałatkiewicz
    • 1
  • Roman Szewczyk
    • 1
  • Eugeniusz Budny
    • 1
  • Tadeusz Missala
    • 1
  • Wojciech Winiarski
    • 1
  1. 1.Industrial Research Institute for Automation and Measurements PIAPWarsawPoland

Personalised recommendations