Abstract
Single-phase-to-earth fault is the most common fault in distribution network. To perfect the existing fault line selection methods and enhance their accuracy in small current grounding system, research on the accuracy of selecting fault feeder has been conducted by many experts in relay protection field. This paper analyzes those common methods on selecting fault line in phase-to-ground system, and summarizes their advantages and shortages. Through systematically analyzing, some new study directions about the accuracy of fault feeder selection are advanced to improve the safe power supply level. This paper may have guiding significance for further fault line selection study.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Liang Rui, Wang Chonglin (2010) Based on fault type comprehensive fault line selection of single-phase base. China Mining University, Xuzhou
Jia Qingquan (2007) The ineffective route network grounding protection technology. National Defence Industry Press, Beijing, pp 80–85
Cheng Changpeng (2004) Ground wire selection and fault locating with ungrounded neutral. Northeast Electr Power Technol 5(6):6–10
Lou Shuqing, Liu Aihua (2009) Small current neutral grounding system fault line selection method. Jiangxi Electr Power 1(33):38–41
Li Peng, Yang Qisun (2004) Based on DSP technology of small current locate single-phase grounding device. Electr Power Autom Equip 3(3):51–52
Zhang Xinhui (2008) Prony algorithm based on small current grounding fault line selection technology. Shandong University, Jinan
Cusido J, Rosero J, Romera L (2006) New techniques for fault detection analysis by injecting additional frequency test. In: Instrumentation and measurement technology conference, IEEE, Sorrento, Italy, pp 2087–2090
Mou Longhua, Meng Qinghai (2003) Power supply security technology. China Machine Press, Beijing, pp 56–65
Xu Weixing (2010) Research on fault line selection in small current grounded system based on evidence theory. Henan University, Zhengzhou
Cheng Zhiliang, Fan Chunjv (2006) Line selection in small current grounded system based on 5 times of harmonic mutations. Proc CSU-EPSA 10(5):37–41
Qi Zheng, Yang Yihan (2004) The technology analysis of earth fault protection in non-solid grounded system. Autom Electr Power Syst 14(28):1–5
Wu Ling, Sun Ying (2003) Application of continuous wavelet transform to select the fault line of single-phase earth faults in non-solid earthed power system. Relay 31(11):20–24
Gong Linchun, Huang Zhixiong (2008) Research of simulating the small current neutral grounding systems fault line selectio10n based on wavelet packets. Comput Eng Sci 3:103–105
Shao Baozhu, Song Dan, Wang Youyin (2008) Fault line selection of single-phase grounding in low current grounding system. Northeast Electr Power Technol 10(8):23–26
He Benteng, Hu Weixian (1998) A new principle to detect the grounded line in a neutral point indirectly grounded power system based on the energy function. J Zhejiang Univ 32(4):451–457
Zhu Dan, Cai Xu (2004) Improved energy function to detect the grounded line in neutral point indirectly grounded network. Power Syst Prot Control 32(10):44–48
Mou Longhua (2000) Grounding protection and fault point positioning. China Mining University Press, Xuzhou, pp 30–45
Liang R, Xue X, Li X (2009) Peterson coils based on changing magnetic coupling to control reactance and its application. AJEEE Aust J Electr Electron Eng 6(2):205–212
Dewadasa M, Ghosh A, Ledwich G (2011) Fault isolation in distributed generation connected distribution networks. Gener Trans Distrib IET 10(5):1053–1061
Shu Hongchun (2008) Fault line selection of distribution power system. China Machine Press, Beijing, pp 50–70
Zhuang Rufeng (2007) The current situation and development tendency of fault line selection devices. Electr Eng Appl 1:11–14
Zeng Jiyong, Ding Hongfa, Duan Xianzhong (2005) A harmonic detect method based on mathematical morphology method. Autom Electr Power Syst 29(6):55–59
Debayle J, Pinoli JC (2005) Multi Scale image filtering and segmentation by means of adaptive neighborhood mathematical morphology. Image Process 3(11):537–540
Chen Weihua (2009) Single line to ground fault line selection in non-direct ground power system based on mathematical morphology method. Central China Electr Power 22(4):4–8
Li Cailin, Zhong Yi, Huang Zhichao (2011) The methods for single phase-to-ground faulty line selection in distribution network. J Guilin Univ Electron Technol 31(5):391–395
Shu Hongehun, Peng Shixin, Li Bin et al (2008) Fault line detecting approach to hybrid feeders consisting of power cables and over head lines in distribution network using extenics. Trans China Electro Tech Soc 23(11):146–153
Mu Daqing, Mo Jingjun (2007) Discussion of fuzzy comprehensive evaluation application on earth fault line selection. Power Syst Prot Control 35(13):1–5
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Zhang, Z., Liu, X. (2014). A Summary of Line Selection in Single Phase Earth Fault System. In: Wang, W. (eds) Mechatronics and Automatic Control Systems. Lecture Notes in Electrical Engineering, vol 237. Springer, Cham. https://doi.org/10.1007/978-3-319-01273-5_53
Download citation
DOI: https://doi.org/10.1007/978-3-319-01273-5_53
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-01272-8
Online ISBN: 978-3-319-01273-5
eBook Packages: EngineeringEngineering (R0)