Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 41))

Abstract

Transcatheter Aortic Valve Implantation (TAVI) is a new minimal-invasive intervention for implanting prosthetic valves in patients with aortic stenosis. This procedure is associated with adverse effects like paravalvular leakage, stroke, and coronary obstruction. Accurate automated sizing for planning and patient selection is expected to reduce these adverse effects. Segmentation of the aortic root in CTA is pivotal to enable automated sizing and planning. We present a fully automated segmentation algorithm to extract the aortic root from CTA images consisting of a number of steps: first, ascending aorta and aortic root centerline were extracted. Subsequently, high intensities due to calcifications are masked to improve segmentation. Next, the aortic root is represented in cylindrical coordinates. Finally, the aortic root is segmented using 3D normalized cuts. We validated the method against manual delineations by calculating Dice coefficients and average distances. The method successfully segmented the aortic root in all 20 image datasets. The mean Dice coefficient was 0.945±0.03 and mean radial absolute error was 0.74 ± 0.39 mm. The proposed algorithm showed accurate results compared to manual segmentations.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this paper

Cite this paper

Elattar, M. et al. (2014). Automated Normalized Cut Segmentation of Aortic Root in CT Angiography. In: Roa Romero, L. (eds) XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013. IFMBE Proceedings, vol 41. Springer, Cham. https://doi.org/10.1007/978-3-319-00846-2_449

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-00846-2_449

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-00845-5

  • Online ISBN: 978-3-319-00846-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics