A novel fiber-optic flow sensor has been developed for monitoring inspiratory efforts during neonatal mechanical ventilation. The considered sensor is based on fiber-optic sensing techniques, allowing the reduction of the effects due to electromagnetic interferences and a possible improvement of the electrical safety conditions. In the arrangement described here, the fiber-optic sensor is able to measure, with an accuracy of 5 %, flow variations in the range between 0.5 l/min and 5 l/min that are the typical flow variations due to infants’ inspiratory attempts and typical flow trigger levels set during assist-control ventilation (ACV). Moreover, a good agreement (r 2 = 0.998) between experimental data and the parabolic theoretical model can be deduced. The metrological characteristics confirm that the novel proposed configuration for the optical fiber air flow sensor is suitable for monitoring flow variations due to infants’ inspiratory attempts.

References

  1. 1.
    F. P. Branca, P. Cappa, S. A. Sciuto and S. Silvestri. A novel methodology for the experimental evaluation of pulmonary ventilator performance drift. Journal of Clinical Engineering. 22, 163–170 (1997)CrossRefGoogle Scholar
  2. 2.
    P. Cappa, S. A. Sciuto and S. Silvestri. A novel preterm respiratory mechanics active simulator to test the performances of neonatal pulmonary ventilators. Review of Scientific Instruments. 73, 2411–2416 (2002)CrossRefGoogle Scholar
  3. 3.
    P. Cappa, S. A. Sciuto and S. Silvestri. Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator. Journal of Medical Engineering & Technology. 30, 31–40 (2006)CrossRefGoogle Scholar
  4. 4.
    P. Saccomandi, E. Schena and S. Silvestri. A novel target-type low pressure drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: measurement principle and static calibration. Review of Scientific Instruments. 82, 024301 (2011).CrossRefGoogle Scholar
  5. 5.
    J. G. Webster and A. M. Cook, Clinical engineering: principles and practices. Englewood Cliffs: Prentice-Hall, NJ (1979)Google Scholar
  6. 6.
    R. C. Baker, Flow measurement handbook: industrial designs, operating principles, performance, and applications (Cambridge University Press, Cambridge, 2000)CrossRefGoogle Scholar
  7. 7.
    B. Lee. Review of the present status of optical fiber sensors. Optical Fiber Technology. 9, 57–79 (2003)CrossRefGoogle Scholar
  8. 8.
    L. Battista, A. Scorza, S. A. Sciuto. Preliminary evaluation of a simple optical fiber measurement system for monitoring respiratory pressure in mechanically ventilated infants. Proc. 9th IASTED Int. Conf. of Biomedical Engineering, 443–449 (2012)Google Scholar
  9. 9.
    L. Battista, A. Scorza, S. A. Sciuto. Experimental characterization of a novel fiber-optic accelerometer for the quantitative assessment of rest tremor in parkinsonian patients. Proc. 9th IASTED Int. Conf. of Biomedical Engineering, 437–442 (2012)Google Scholar
  10. 10.
    L. Battista, S. A. Sciuto, A. Scorza. Preliminary evaluation of a fiber-optic sensor for flow measurements in pulmonary ventilators. Proc. 2011 IEEE Int. Symp. on Medical Measurements and Applications, 29–34 (2011)Google Scholar
  11. 11.
    L. Battista, S. A. Sciuto, A. Scorza. An air flow sensor for neonatal mechanical ventilation application based on a novel fiber-optic sensing technique. Review of Scientific Instruments. 84 (3), 035005 (2013). doi:  10.1063/1.4798298 CrossRefGoogle Scholar
  12. 12.
    U. Frey et al. Specifications for equipment used for infant pulmonary function testing. Eur Respir J. 16, 731–740 (2000)MathSciNetCrossRefGoogle Scholar
  13. 13.
    Ghulam Nabi. Mechanical Ventilation in Infants. JK-Practitioner. 12, 31–33 (2005)Google Scholar

Copyright information

© Springer International Publishing Switzerland 2014

Authors and Affiliations

  • Luigi Battista
    • 1
    • 2
  • Andrea Scorza
    • 1
  • Salvatore Andrea Sciuto
    • 1
  1. 1.Department of EngineeringUniversity of Rome “ROMA TRE”RomeItaly
  2. 2.CNR – National Institute of OpticsPozzuoliItaly

Personalised recommendations