Abstract

The automation of the thermal analysis instruments, differential thermal analysis (DTA) and the thermobalance, is described. The DTA instrument is capable of studying eight individual samples, each contained in a glass capillary tube,in a Sequential manner. The samples are automatically introduced into the furnace, pyrolyzed to a preselected temperature limit, and then removed. After cooling the furnace back to room temperature, the cycle is repeated. Operation of the sample changing mechanism, furnace temperature programming, recording, and so on, is completely automatic.

The thermobalance is capable of recording the TG curves of eight samples in a sequential manner. The instrument consists of a recording top-loading balance, a furnace and temperature programmer, and an automatic sample changer. Each sample in the sample holder disk is positioned into the furnace automatically, heated to a preselected temperature, and then removed. After the furance is cooled back to room temperature, the cycle is repeated with a new sample. Operation of the thermobalance is completely automatic and it requires no operator attention once the cycle is begun.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. W. W. Wendlandt and W. S. Bradley, Anal. Chim. Acta 52, 397 (1970).

    Article  Google Scholar 

  2. W. C. Roberts-Austen, Metallographist 2, 186 (1899).

    Google Scholar 

  3. W. J. Smothers and Y. Chiang, “Differential Thermal Analysis: Theory and Practice,” Chemical Publishing Co., New York, 1958, pp. 294–399.

    Google Scholar 

  4. W. J. Smothers and Y. Chiang, “Handbook of Differential Thermal Analysis,” Chemical Publishing Co., New York, 1966.

    Google Scholar 

  5. W. W. Wendlandt, “Thermal Methods of Analysis,” Inter-science, J. Wiley, New York, 1964, Chapter 6.

    Google Scholar 

  6. P. D. Garn, “Thermoanalytical Methods of Investigation,” Academic Press, New York, 1965, Chapter 4.

    Google Scholar 

  7. Reference (3), Chapter 8.

    Google Scholar 

  8. E. M. Barrall and J. F. Johnson in “Techniques and Methods of Polymer Evaluation,” P. E. Slade and L. T. Jenkins, Eds., M. Dekker, New York, 1966, Chapter 1.

    Google Scholar 

  9. Anon., Industrial Research Nov. 1969, p. 25.

    Google Scholar 

  10. W. W. Wendlandt, J. Chem. Educ. 38, 571 (1961).

    Article  Google Scholar 

  11. W. W. Wendlandt, Thermochim. Acta, 1 (1970).

    Google Scholar 

  12. W. S. Bradley and W. W. Wendlandt, Anal. Chem. 43, 223 (1971).

    Article  Google Scholar 

  13. K. Honda, Sci. Rep. Tohoku Univ. 4, 97 (1915).

    Google Scholar 

  14. H. Saito, “Thermobalance Analysis,” Gijitsu Shoin, Tokyo, 1962.

    Google Scholar 

  15. M. Guichard, Bull. Soc. Chim. France 33, 258 (1923).

    Google Scholar 

  16. S. Gordon and C. Campbell, Anal. Chem. 32, 271R (1960).

    Google Scholar 

  17. C. Duval, “Inorganic Thermogravimetric Analysis,” Second Ed., Elsevier, Amsterdam, 1963.

    Google Scholar 

  18. C. Keattch, “An Introduction to Thermogravimetry,” Heyden, London, 1969.

    Google Scholar 

  19. H. Saito, “Thermal Analysis,” R. F. Schwenker and P. D. Garn, Eds., Academic Press, New York, N. Y., 1969, pp. 11–24.

    Google Scholar 

  20. H. C. Anderson, “Techniques and Methods of Polymer Evaluation,” P. E. Slade and L. T. Jenkins, Eds., Dekker, New York, N. Y., 1966, Chapter 3.

    Google Scholar 

  21. W. W. Wendlandt, Lab. Management October 26 (1965).

    Google Scholar 

  22. H. G. Wiedemann, Chem. Inq. Technik 36, 1105 (1964).

    Google Scholar 

  23. F. Paulik, J. Paulik and L. Erdey, Z. Anal. Chem. 160, 241 (1958).

    Article  Google Scholar 

  24. J. R. Allan, D. H. Brown, R. H. Nuttall and D. W. A. Sharp, J. Inorg. Nucl. Chem. 26, 1895 (1964).

    Article  Google Scholar 

  25. L. R. Ocone, J. R. Soulen and B. P. Block, J. Inorg. Nucl. Chem. 15, 76 (1960).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1972 Springer Basel AG

About this chapter

Cite this chapter

Wendlandt, W.W. (1972). The Automation of Thermal Analysis Instrumentation: Thermogravimetry and Differential Thermal Analysis. In: Wiedemann, H.G. (eds) Advances in Instrumentation. Birkhäuser, Basel. https://doi.org/10.1007/978-3-0348-7413-7_1

Download citation

  • DOI: https://doi.org/10.1007/978-3-0348-7413-7_1

  • Publisher Name: Birkhäuser, Basel

  • Print ISBN: 978-3-0348-7415-1

  • Online ISBN: 978-3-0348-7413-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics