Nitinol alloys stents have been printed by Selective Laser Melting from a gas atomized powder with a composition of 50.8 at% Ni. The energy density has been adapted to set the austenite finish temperature just below the human body temperature, therefore the stent diameter can be reduced by plastic strain at lower temperature and recover its former expanded shape after being inserted in the artery. Several mesh geometries have been mechanically analyzed by finite elements modeling to ensure that the local strain will not exceed superelastic reversible capacity of 4% while squeezing the stent diameter by a factor of 4. The stent surface has been treated by electropolishing to reduce its roughness to Ra < 0.02 mm. After polishing, some samples have been coated by a 50 nm thick TiO2 layer by Atomic Layer Deposition. Biocompatibility and hemocompatibility analysis demonstrated that the TiO2 coating significantly improved hemocompatibility. Nevertheless, uncoated stents are also biocompatible and hemocompatible according to ISO-10993–12 guidelines.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Parvizi, S.P., Mahdi, H.S., Asgarinia, F., Nematollahi, M., Elahinia, M.: Effective parameters on the final properties of NiTi-based alloys manufactured by powder metallurgy methods: a review. Prog. Mater. Sci. 117, 100739 (2021)
Bayati, P., et al.: Toward low and high cycle fatigue behavior of SLM-fabricated NiTi: considering the effect of build orientation and employing a self-heating approach. Int. J. Mech. Sci. 185 105878 (2020)
Speirs, M., Van Hooreweder, B., Van Humbeeck, J., Kruth, J.-P.: Fatigue behaviour of NiTi shape memory alloy scaffolds produced by SLM, a unit cell design comparison. J. Mech. Behav. Biomed. Mater. 70, 53–59 (2017)
Moghaddam, N.S., et al.: Achieving super elasticity in additively manufactured NiTi in compression without post-process heat treatment. Nat. Sci. Rep. 9, 14 (2019)
Patoor, E., Berveillier, M.: Technologie des alliages à mémoire de forme, Ed. HERMES, Paris (1994)
Schmidt, P., Cornu, P., Angelillo-Scherrer, A.: Bases physiopathologiques en hématologie générale. Un aide-mémoire d’hématologie. Service d’Hématologie, CHUV, Lausanne (2014)
Acknowledgements
The authors want to acknowledge the University of Applied Sciences and Arts of Western Switzerland (HES-SO) for funding this research.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Pralong, J. et al. (2024). Nitinol Stents Printed by Selective Laser Melting. In: Mabrouki, T., Sahlaoui, H., Sallem, H., Ghanem, F., Benyahya, N. (eds) Advances in Additive Manufacturing: Materials, Processes and Applications. AIAM 2023. Lecture Notes in Mechanical Engineering. Springer, Cham. https://doi.org/10.1007/978-3-031-47784-3_5
Download citation
DOI: https://doi.org/10.1007/978-3-031-47784-3_5
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-47783-6
Online ISBN: 978-3-031-47784-3
eBook Packages: EngineeringEngineering (R0)