Diabetic foot is a complication that carries a considerable risk in diabetic patients. The consequent loss of protective sensitivity in the lower limbs requires an early diagnosis due to the imminent possibility of ulceration or amputation of the affected limb. To assess the loss of protective sensitivity, the 10 gf Semmes-Weinstein (SW) monofilament is the most used first-line procedure. However, the used device is most often non-calibrated and its feedback can lead to decision errors. In this paper we present an equipment that is able to automatically conduct a metrological verification and evaluation of the 10 gf SW monofilament in the assessment of the loss of protective sensitivity. Additionally, the proposed equipment is able to simulate the practicioner’s procedure, or can be used for training purposes, providing force-feedback information. After calibration, displacement vs. buckling force contours were plotted for three distinct monofilaments, confirming then ability of the equipment to provide fast, detailed and precise information.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bus, S.A., et al.: Guidelines on offloading foot ulcers in persons with diabetes (iwgdf 2019 update). Diabetes/Metabolism Res. Rev. 36(S1:e3274), 1–18 (2020)
Bus, S.A., et al.: Guidelines on the prevention of foot ulcers in persons with diabetes (iwgdf 2019 update). Diabetes/Metabolism Res. Rev. 36(S1:e3269), 1–18 (2020)
Chikai, M., Ino, S.: Buckling force variability of semmes-weinstein monofilaments in successive use determined by manual and automated operation. Sensors MDPI 19(4) (2019)
Costa, T., Coelho, L., Silva, M.F.: Automatic segmentation of monofilament testing sites in plantar images for diabetic foot management. Bioengineering 9(3), 86 (2022)
Costa, T., Coelho, L., Silva, M.F.: Integrating computer vision, robotics, and artificial intelligence for healthcare: An application case for diabetic foot management. In: Coelho, L., Queiros, R. (eds.) Exploring the Convergence of Computer and Medical Science Through Cloud Healthcare, p. 29. IGI Global (2023)
Lavery, L.A., Lavery, D.E., Lavery, D.C., Lafontaine, J., Bharara, M., Najafi, B.: Accuracy and durability of semmes-weinstein monofilaments: what is the useful service life? Diabetes Res. Clin. Pract. 97, 399–404 (2012)
Martins, P., Coelho, L.: Evaluation of the semmes-weinstein monofilament on the diabetic foot assessment. In: Advances and Current Trends in Biomechanics. CRC Press, Porto (2021)
Olaiya, M.T.: Use of graded semmes weinstein monofilament testing for ascertaining peripheral neuropathy in people with and without diabetes. Diabetes Res. Clin. Pract. 151, 1–10 (2019)
Wang, F., et al.: Diagnostic accuracy of monofilament tests for detecting diabetic peripheral neuropathy: a systematic review and meta-analysis. J. Diabetes Res, 2017(8787261) (2017)
Young, M.: A perfect 10? why the accuracy of your monofilament matters. Diabetes Primary Care 11, 40–43 (2009)
Acknowledgements
This work was partially supported by grant FCT-UIDB/04730/2020.
Author information
Authors and Affiliations
Corresponding authors
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Castro-Martins, P., Pinto-Coelho, L. (2024). A New Equipment for Automatic Calibration of the Semmes-Weinstein Monofilament. In: Silva, F.J.G., Pereira, A.B., Campilho, R.D.S.G. (eds) Flexible Automation and Intelligent Manufacturing: Establishing Bridges for More Sustainable Manufacturing Systems. FAIM 2023. Lecture Notes in Mechanical Engineering. Springer, Cham. https://doi.org/10.1007/978-3-031-38241-3_21
Download citation
DOI: https://doi.org/10.1007/978-3-031-38241-3_21
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-38240-6
Online ISBN: 978-3-031-38241-3
eBook Packages: EngineeringEngineering (R0)