Abstract
The lead extraction procedures are for the patients who already have pacemaker implanted and leads need to be replaced. The procedure is a high-risk procedure and it could lead to major complications or even procedure-related death. Recently, an Electra Registry Outcome Score (EROS) was designed to create a risk assessment tool using the data about personal health records and an accuracy of 0.70 was achieved. In this paper, we hypothesized that a coil inside the superior vena cava (SVC) is a very important risk factor. By integrating it into the risk assessment model, the accuracy can be further improved. Therefore, an automatic detection method was developed to localize the positions of coils in the X-ray images. It was based on a U-Net convolutional network. To determine the coil position relative to the SVC position inside the chest X-ray image, the heart region was first detected by using a modified VGG16 model. Then, the bounding box of the SVC can be estimated based on the heart anatomy. Finally, a XGBoost classifier was trained on the data about personal health records and the risk factor about the coil position. An accuracy of 0.85 was achieved.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
van Erven, L., et al.: Attitude towards redundant leads and the practice of lead extractions: a European survey. Europace 12(2), 275–276 (2010)
Bongiorni, M.G., et al.: The European Lead Extraction ConTRolled (ELECTRa) study: A European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes. European Heart Journal 38(40), 2995–3005 (2017)
Sidhu, B.S., et al.: Risk stratification of patients undergoing transvenous lead extraction with the ELECTRa Registry Outcome Score (EROS): an ESC EHRA EORP European lead extraction ConTRolled ELECTRa registry analysis. Europace 23(9), 1462–1471 (2021)
Mehta, V.S., et al.: Machine learning–derived major adverse event prediction of patients undergoing transvenous lead extraction: Using the ESC EHRA EORP European lead extraction ConTRolled ELECTRa registry. Heart Rhythm 19(6), 885–893 (2022)
Tułecki, Ł, et al.: A Study of Major and Minor Complications of 1500 Transvenous Lead Extraction Procedures Performed with Optimal Safety at Two High-Volume Referral Centers. International journal of environmental research and public health 18(19), 10416–29 (2021)
Ronneberger, O., et al.: U-Net: Convolutional Networks for Biomedical Image Segmentation. In: Proc. Int. Conf. Medical Image Computer Assisted Intervention (MICCAI), LNCS, vol 9351, pp. 234–241. Springer (2015)
Frangi, A.F., et al.: Multiscale vessel enhancement filtering. In: Proc. Int. Conf. Medical Image Computer Assisted Intervention (MICCAI) (1998)
Otsu, N.: A threshold selection method from gray-level histograms. IEEE Transactions on Systems, Man and Cybernetics 9(1), 62–66 (1979)
Tułecki, Ł, et al.: Analysis of Risk Factors for Major Complications of 1500 Transvenous Lead Extraction Procedures with Especial Attention to Tricuspid Valve Damage. Int. J. Environ. Res. Pub. Heal. 18(17), 9100–9113 (2021)
Li, J., et al.: Transfer Learning Performance Analysis for VGG16 in Hurricane Damage Building Classification. In: 2nd International Conference on Big Data & Artificial Intelligence & Software Engineering (ICBASE), pp 177–184 (2021)
Chen, T., et al.: XGBoost: A Scalable Tree Boosting System. In: Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining (KDD ‘16), pp 785–794 (2016)
Ogunleye, A., et al.: XGBoost model for chronic kidney disease diagnosis. IEEE/ACM Transactions on Computational Biology and Bioinformatics 17(6), 2131–2140 (2020)
Abdulghani, A.Q., et al.: Credit card fraud detection using XGBoost algorithm. In: 14th International Conference on Developments in eSystems Engineering, pp. 487–492 (2021)
Acknowledgements
This work is funded by a EPSRC grant (EP/X023826/1). The study was also supported by the Wellcome/EPSRC Centre for Medical Engineering (WT203148/Z/16/Z) and the National Institute for Health Research (NIHR) Biomedical Research Centre based at Guy's and St Thomas' NHS Foundation Trust and King's College London. The views expressed are those of the author(s) and not necessarily those of the NHS, the NIHR or the Department of Health.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2023 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Ma, Y., Mehta, V.S., Rinaldi, C.A., Hu, P., Niederer, S., Razavi, R. (2023). Automatic Detection of Coil Position in the Chest X-ray Images for Assessing the Risks of Lead Extraction Procedures. In: Bernard, O., Clarysse, P., Duchateau, N., Ohayon, J., Viallon, M. (eds) Functional Imaging and Modeling of the Heart. FIMH 2023. Lecture Notes in Computer Science, vol 13958. Springer, Cham. https://doi.org/10.1007/978-3-031-35302-4_32
Download citation
DOI: https://doi.org/10.1007/978-3-031-35302-4_32
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-35301-7
Online ISBN: 978-3-031-35302-4
eBook Packages: Computer ScienceComputer Science (R0)