Abstract
Understanding the relationship between frequency f [Hz] and wavelength λ [m] is fundamental for a professional EMC design engineer. This chapter introduces the term wavelength λ and explains how the wavelength of an electromagnetic wave depends on the cable insulation or PCB material.
If you want to find the secrets of the universe, think in terms of energy, frequency and vibration.
—Nikola Tesla
You have full access to this open access chapter, Download chapter PDF
Keywords
- Frequency
- Wavelength
- Wavelength in vacuum
- Wavelength in free-space
- Wavelength in a conductor
- Wavelength in a cable
- Wavelength in any media
- Propagation velocity
- Propagation constant
- Velocity factor
- International telecommunication union (ITU)
- ITU frequency bands
- Effective dielectric constant
4.1 EMC and Frequencies
In general, conducted EMC emission and immunity tests take place at lower frequencies than radiated EMC emission and immunity tests.
-
Conducted RF Emissions. It is assumed that connected cables to electric equipment could act as antennas (in case of conducted emissions from the equipment induced into these cables). Therefore, conducted RF emission limits exist to avoid radiation of connected cables (power, communication). Usually, conducted RF emissions are specified for frequencies f = 150 kHz to 30 MHz [1].
-
Radiated RF Emissions. Radiated RF emissions tend to occur at higher frequencies (in the megahertz range, depending on the equipment’s maximum dimensions [m]). Therefore, regulators usually specify the maximum RF radiation limits for frequencies from f = 30 MHz to f = 6 GHz [1].
-
Conducted RF Immunity. As stated above, connected cables are thought to act as antennas. Therefore, conducted RF immunity tests exist to evaluate the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced to connected cables by RF fields. Conducted RF immunity tests are usually performed with frequencies from f = 150 kHz to 80 MHz [4].
-
Radiated RF Emissions. Radiated RF immunity tests are intended to demonstrate the immunity of electrical and electronic equipment when subjected to wireless devices like mobile phones and other radiated interference. Radiated RF immunity tests are usually performed with frequencies from f = 80 MHz to 6 GHz [3].
-
Radiated Magnetic Field Immunity. Magnetic field immunity tests are usually performed at mains power frequency: 50 and 60 Hz [5].
-
Common-Mode Low-Frequency Disturbance. In some areas, there are also conducted EMC immunity tests specified from f = 0 Hz to f = 150 kHz [2]. This is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted common-mode disturbances such as those originating from power line currents, frequency converters, and return leakage currents in the earthing/grounding system.
The radio spectrum managed by the International Telecommunication Union (ITU) goes up to 3000 GHzFootnote 1 and is divided into 12 ITU frequency bands . Table 4.1) shows the ITU frequency bands with their corresponding wavelength and potential applications.
4.2 Wavelength vs. Frequency
4.2.1 Wavelength in Any Media
The frequency f [Hz] of a sinusoidal electromagnetic wave (Fig. 4.1) and its wavelength λ [m] have the following relationship [6]:
where:
-
v = propagation velocity of the signal in [m/sec]
-
f = frequency of the sinusoidal signal in [Hz]
-
β = propagation constant in [1/m]; see Eq. 7.53
-
𝜖′ = real part of the complex permittivity \( \underline {\epsilon } = \epsilon ' - j \epsilon ''\) of the medium through which the wave is traveling in [F/m]
-
𝜖″ = imaginary part of the complex permittivity \( \underline {\epsilon } = \epsilon ' - j \epsilon ''\) of the medium through which the wave is traveling in [F/m]
-
μ′ = real part of the complex permeability \( \underline {\mu } = \mu ' - j \mu ''\) of the medium through which the wave is traveling in [H/m]
-
μ″ = imaginary part of the complex permeability \( \underline {\mu } = \mu ' - j \mu ''\) of the medium through which the wave is traveling in [H/m]
4.2.2 Wavelength in Insulating Media
In case of an insulator (\(\mu _r^{\prime } = 1\)) and negligible dielectric and magnetic losses (𝜖″ = 0, μ″ = 0), the wavelength of a sinusoidal electromagnetic wave with frequency f [Hz] can be written as:
where:
-
v = propagation velocity of the signal in [m/sec]
-
f = frequency of the sinusoidal signal in [Hz]
-
\(c = 1/(\sqrt {\mu _0\epsilon _0}) = 2.998 \cdot 10^{8}\) m/sec = speed of light
-
μ 0 = 12.57 ⋅ 10−7 H/m = permeability of vacuum, absolute permeability
-
𝜖 0 = 8.854 ⋅ 10−12 F/m = permittivity of vacuum, absolute permittivity
-
\(\epsilon _r^{\prime } =\) relative permittivity, dielectric constant of the insulator
4.2.3 Wavelength in Vacuum
For vacuum (and approximately air), the calculation of the wavelength of a sinusoidal electromagnetic wave reduces to [10]:
where:
-
\(c = 1/(\sqrt {\mu _0\epsilon _0}) = 2.998 \cdot 10^{8}\) m/sec = speed of light
-
f = frequency of the sinusoidal signal in [Hz]
4.2.4 Wavelength in Good Conducting Media
In case the electromagnetic sinusoidal wave travels through a good conductor (through and not along(!), e.g., through a shield) with negligible magnetic losses (μ″ = 0), the wavelength can be calculated as [10]:
where:
-
f = frequency of the sinusoidal signal in [Hz]
-
\(\mu ' = \mu _r^{\prime }\mu _0 =\) real part of the complex permeability (\( \underline {\mu } = \mu ' - j \mu ''\)) in [H/m]
-
σ = specific conductance of the medium where the wave is propagating through in [S/m]
4.3 Wavelength of Signals Along Wires, Cables, and PCB Traces
It is important to understand that the signal propagation velocity v [m/sec] depends on the transport medium through which the electromagnetic field is traveling. Therefore, the same signal with the same frequency f [Hz] has a different wavelength λ [m] in a blank wire (surrounded by air) than in a cable or PCB trace (surrounded by one or multiple insulation materials). The wavelength λ of signals traveling along wires, cables, and PCB traces—where the dielectric and magnetic losses can be neglected (𝜖″ = 0, μ″ = 0) and the materials around the conductors are assumed to be nonmagnetic (\(\mu _r^{\prime }=1\))—is given as [9]:
where:
-
v = propagation velocity of the signal in [m/sec]
-
f = frequency of the sinusoidal signal in [Hz]
-
c = 2.998 ⋅ 108 m/sec = speed of light
-
𝜖 reff = effective relative permittivity (dielectric constant) of the material(s) through which the electromagnetic field is propagating
-
VF = velocity factor
4.3.1 Wavelength of Signals Along Blank Wires
The wavelength λ [m] of a signal with frequency f [Hz] which travels along a blank wire (or antenna surrounded by air) depends only on the speed of light c [m/sec] and the signal frequency f [Hz] (v = c, because \(\epsilon _r^{\prime } = 1\) and \(\mu _r^{\prime } = 1\) and therefore VF = 1) [9]:
where:
-
\(c = 1/(\sqrt {\mu _0\epsilon _0}) = 2.998 \cdot 10^{8}\) m/sec = speed of light
-
f = frequency of the sinusoidal signal in [Hz]
4.3.2 Wavelength of Signals Along Cables and PCB Traces
The wavelength λ of a signal with frequency f which travels along a wire, cable , or a printed circuit board (PCB) trace is [9]:
where:
-
\(c = 1/(\sqrt {\mu _0\epsilon _0}) = 2.998 \cdot 10^{8}\) m/sec = speed of light
-
f = frequency of the sinusoidal signal in [Hz]
-
𝜖 reff = the effective dielectric constant (relative permittivity) through which the electromagnetic wave is propagating
The effective dielectric constant 𝜖 reff is defined as the uniform equivalent dielectric constant for a transmission line , even in the presence of different dielectrics (e.g., FR-4 and air for a microstrip line; see Fig. 4.2a). The relative permeability \(\mu _r^{\prime }\) is assumed to be equal 1.0 for cables and PCBs, because the insulation materials are nonmagnetic. Thus, the velocity factor (VF) depends primarily on the effective relative permittivity 𝜖 reff through which the electromagnetic wave is propagating.
The calculation of the effective dielectric constant 𝜖 reff depends on the insulation material and the geometry of the transmission line (e.g., ribbon cable, microstrip, coplanar waveguide, etc.), because the amount of electric field lines in the different media depends on the geometry of the transmission line. Figure 4.2 shows some common transmission lines and Table 4.2 the corresponding 𝜖 reff
The velocity factor (VF) of a transmission medium is the ratio of the velocity v [m/sec] at which a wavefront of an electromagnetic signal passes through the medium, compared to the speed of light in vacuum c = 2.998 ⋅ 108 m/sec:
Thus, the smaller the velocity factor (VF), the smaller the wavelength λ [m].
During EMC emission measurement and troubleshooting, it is often necessary to determine the wavelength λ [m] of a certain unintended disturbance with frequency f [Hz] because once you know the wavelength of the disturbance, you can look for potential antennas of the disturbance (e.g., looking for cables with length l = λ∕4 or l = λ∕2 of the disturbance). Table 4.3 presents the velocity factors for different 𝜖 reff and the resulting wavelength λ [m] for a given frequency f [Hz].
4.3.3 Summary
-
Wavelength. The wavelength λ [m] of a sinusoidal signal with frequency f [Hz] depends on the media through which the electromagnetic wave is propagating because the velocity v [m/sec] changes with the dielectric and magnetic properties \( \underline {\epsilon }\) [F/m], \( \underline {\mu }\) [H/m].
-
Wavelength of signals along conductors.
$$\displaystyle \begin{aligned} \lambda = v/f = c/(f\sqrt{\epsilon_{reff}}) \end{aligned} $$(4.9)where:
-
v = propagation velocity of the signal in [m/sec]
-
f = frequency of the sinusoidal signal in [Hz]
-
𝜖 reff = the effective dielectric constant (relative permittivity) through which the electromagnetic wave is propagating
-
-
Wavelength of electromagnetic waves in free-space.
$$\displaystyle \begin{aligned} \lambda = c/f \end{aligned} $$(4.10)where:
-
\(c = 1/(\sqrt {\mu _0\epsilon _0}) = 2.998 \cdot 10^{8}\) m/sec = speed of light
-
f = frequency of the sinusoidal electromagnetic wave in [Hz]
-
Notes
- 1.
Radio waves are electromagnetic waves of frequencies arbitrarily lower than 3000 GHz (3 THz), propagated in space without artificial guide. 3 THz is already in the infrared frequency band (300 GHz–430 THz); visible light starts at 430 THz.
References
CISPR 32 Electromagnetic compatibility of multimedia equipment – Emission requirements. International Electrotechnical Commission (IEC). 2015.
Electromagnetic compatibility (EMC) - Part 4–16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz. International Electrotechnical Commission (IEC). 2015.
Electromagnetic compatibility (EMC) - Part 4–3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test. International Electrotechnical Commission (IEC). 2020.
Electromagnetic compatibility (EMC) - Part 4–6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields. International Electrotechnical Commission (IEC). 2013.
Electromagnetic compatibility (EMC) - Part 4–8: Testing and measurement techniques - Power frequency magnetic field immunity test. International Electrotechnical Commission (IEC). 2009.
Arthur von Hippel. Dielectrics and Waves. Artech House, 1954.
Peter Lefferson. “Twisted Magnet Wire Transmission Line”. In: IEEE Transactions on parts, hybrids, and packaging Vol. PHP-7.No. 4 (1971).
R. Majidi-Ahy M. Riaziat I.J. Feng and B.A. Auld. “Single-mode operation of coplanar waveguides”. In: Electronic Letters (No. 24 Nov. 19, 1987).
Clayton R. Paul. Introduction to electromagnetic compatibility. 2nd edition. John Wiley & Sons Inc., 2008.
David M. Pozar. Microwave engineering. 4th edition. Newens, 2012.
Radio Regulations - Articles. International Telecommunication Union (ITU). 2020.
Brian C. Wadell. Transmission line design handbook. Artech House Inc.,1991.
Author information
Authors and Affiliations
Rights and permissions
Open Access This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.
The images or other third party material in this chapter are included in the chapter's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
Copyright information
© 2023 The Author(s)
About this chapter
Cite this chapter
Keller, R.B. (2023). Frequency and Wavelength. In: Design for Electromagnetic Compatibility--In a Nutshell. Springer, Cham. https://doi.org/10.1007/978-3-031-14186-7_4
Download citation
DOI: https://doi.org/10.1007/978-3-031-14186-7_4
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-14185-0
Online ISBN: 978-3-031-14186-7
eBook Packages: EngineeringEngineering (R0)