Abstract
Rationale Paralyzed muscles can be reanimated following spinal cord injury (SCI) using a brain-computer interface (BCI) to enhance motor function alone. Importantly, the sense of touch is a key component of motor function. Simultaneously restoring the sense of touch and movement would meet functional needs for BCI users that seek to enhance upper limb function following SCI. Methods The study met institutional requirements for the conduct of human subjects and is registered on the http://www.ClinicalTrials.gov website (identifier: NCT01997125). The participant was a 27-year-old male with stable, non-spastic C5 quadriplegia resulting from a cervical SCI. The participant underwent implantation of a 96 channel Utah microelectrode recording array (Blackrock Microsystems, Inc.; Salt Lake, Utah) in his left primary motor cortex. The hand area of motor cortex was identified preoperatively by fusing functional magnetic resonance imaging (fMRI) activation maps obtained while the participant attempted movements co-registered to the preoperative planning MRI. During experiments, the participant was either completely blinded to the experimental conditions or given brief instructions to complete the necessary actions. Cue and trial parameters were randomized as needed. Results Results are adapted from (Ganzer PD, Colachis 4th SC, Schwemmer MA, Friedenberg DA, Dunlap CF, Swiftney CE, Sharma G in Restoring the sense of touch using a sensorimotor demultiplexing neural interface. Cell 2020). We demonstrate that a human participant with a clinically complete SCI can use a BCI to simultaneously reanimate both motor function and the sense of touch, leveraging residual touch signaling from their own hand. In primary motor cortex (M1), residual subperceptual hand touch signals are simultaneously demultiplexed from ongoing efferent motor intention, enabling intracortically controlled closed-loop sensory feedback. Using the closed-loop demultiplexing BCI almost fully restored the ability to detect object touch, and significantly improved several sensorimotor functions. Conclusion These results demonstrate that subperceptual neural signals can be decoded from human cortex and transformed into conscious perception, significantly augmenting function.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ganzer PD, Colachis SC IV, Schwemmer MA., Friedenberg DA, Dunlap CF, Swiftney CE, Sharma G (2020) Restoring the sense of touch using a sensorimotor demultiplexing neural interface. Cell
Wrigley PJ, Siddall PJ, Gustin SM (2018) New evidence for preserved somatosensory pathways in complete spinal cord injury: a fMRI study. Hum Brain Mapp 39(1):588–598
Awad A, Levi R, Lindgren L, Hultling C, Westling G, Nyberg L, Eriksson J (2015) Preserved somatosensory conduction in a patient with complete cervical spinal cord injury. J Rehabil Med 47(5):426–431. https://doi.org/10.2340/16501977-1955
Ioannides AA, Liu L, Khurshudyan A, Bodley R, Poghosyan V, Shibata T, Dammers J, Jamous A (2002) Brain activation sequences following electrical limb stimulation of normal and paraplegic subjects. Neuroimage 16(1):115–129
Sabbah P, De SS, Leveque C, Gay S, Pfefer F, Nioche C, Sarrazin JL, Barouti H, Tadie M, Cordoliani YS (2002) Sensorimotor cortical activity in patients with complete spinal cord injury: a functional magnetic resonance imaging study. J Neurotrauma 19(1):53–60
Anderson KD (2004) Targeting recovery: priorities of the spinal cord-injured population. J Neurotrauma 21:1371–1383
Snoek GJ, IJzerman MJ, Hermens HJ, Maxwell D and Biering-Sorensen F (2004) Survey of the needs of patients with spinal cord injury: impact and priority for improvement in hand function in tetraplegics. Nat Spinal Cord 42 526–32
Blabe CH, Gilja V, Chestek CA, Shenoy KV, Anderson KD, Henderson JM (2015) Assessment of brain–machine interfaces from the perspective of people with paralysis. J Neural Eng 12:1–9
Lebedev MA, Nicolelis MAL (2017) Brain-machine interfaces: from basic science to neuroprostheses and neurorehabilitation. Physiol Rev 97:767–837
Hochberg LR et al (2012) Reach and grasp by people with tetraplegia using a neurally controlled robotic arm. Nature 485:372–375
Collinger JL et al (2013) High-performance neuroprosthetic control by an individual with tetraplegia. The Lancet 381:557–564
Gilja V et al (2015) Clinical translation of a high-performance neural prosthesis. Nat Med 21:1142–1145
Simeral JD, Kim SP, Black MJ, Donoghue JP, Hochberg LR (2011) Neural control of cursor trajectory and click by a human with tetraplegia 1000 days after implant of an intracortical microelectrode array. J Neural Eng 8:025027
Jarosiewicz B et al (2015) Virtual typing by people with tetraplegia using a self-calibrating intracortical brain–computer interface. Sci Transl Med 7:313ra179
Bockbrader MA, Francisco G, Lee R, Olson J, Solinsky R, Boninger ML (2018) Brain computer interfaces in rehabilitation medicine. PM&R. 10(9S2):S233-S243. doi: https://doi.org/10.1016/j.pmrj.2018.05.028
Moxon KA, Foffani G (2015) Brain-machine interfaces beyond neuroprosthetics. Neuron 86(1):55–67. https://doi.org/10.1016/j.neuron.2015.03.036
Bouton CE, Shaikhouni A, Annetta NV, Bockbrader MA, Friedenberg DA, Nielson DM, Sharma G, Sederberg PB, Glenn BC, Mysiw WJ, Morgan AG, Deogaonkar M, Rezai AR (2016) Restoring cortical control of functional movement in a human with quadriplegia. Nature 533(7602):247–250
Friedenberg DA, Schwemmer MA, Landgraf AJ, Annetta NV, Bockbrader MA, Bouton CE, Zhang M, Rezai AR, Mysiw WJ, Bresler HS, Sharma G (2017) Neuroprosthetic enabled control of graded arm muscle contraction in a paralyzed human. Sci Rep 7(1):8386
Sharma G, Friedenberg DA, Annetta N, Glenn B, Bockbrader M, Majstorovic C, Domas S, Mysiw WJ, Rezai A, Bouton C (2016) Using an artificial neural bypass to restore cortical control of rhythmic movements in a human with quadriplegia. Sci Rep 6:33807. https://doi.org/10.1038/srep33807
Skomrock ND, Schwemmer MA, Ting JE, Trivedi HR, Sharma G, Bockbrader MA, Friedenberg DA (2018) A characterization of brain-computer interface performance trade-offs using support vector machines and deep neural networks to decode movement intent. Front Neurosci 12:763. https://doi.org/10.3389/fnins.2018.00763
Schwemmer MA, Skomrock ND, Sederberg PB, Ting JE, Sharma G, Bockbrader MA, Friedenberg DA (2018) Meeting brain-computer interface user performance expectations using a deep neural network decoding framework. Nat Med 24:1669–1676. https://doi.org/10.1038/s41591-018-0171-y
Colachis SC 4th, Bockbrader MA, Zhang M, Friedenberg DA, Annetta NV, Schwemmer MA, Skomrock ND, Mysiw WJ, Rezai AR, Bresler HS, Sharma G (2018) Dexterous control of seven functional hand movements using cortically-controlled transcutaneous muscle stimulation in a person with tetraplegia. Front Neurosci 12:208. https://doi.org/10.3389/fnins.2018.00208
Ajiboye AB et al (2017) Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration. The Lancet. https://doi.org/10.1016/S0140-6736(17)30601-3
Bockbrader M, Annetta N, Friedenberg D, Schwemmer M, Skomrock N, Colachis S 4th, Zhang M, Bouton C, Rezai A, Sharma G, Mysiw WJ (2019) Clinically significant gains in skillful grasp coordination by an individual with tetraplegia using an implanted brain-computer interface with forearm transcutaneous muscle stimulation. Arch Phys Med Rehabil. pii:S0003–9993(19)30163–7. doi: https://doi.org/10.1016/j.apmr.2018.07.445
Manohar A, Foffani G, Ganzer PD, Bethea J, Moxon KA (2017) Cortex dependent recovery of unassisted hindlimb locomotion after complete spinal cord injury in the adult rat. eLife 6 pii: e23532
Ganzer PD, Moxon KA, Knudsen EB, Shumsky JS (2013) Serotonergic pharmacotherapy promotes cortical reorganization after spinal cord injury. Exp Neurol 241:84–94
Annetta N, Friend J, Schimmoeller A, Buck VS, Friedenberg D, Bouton CE, Bockbrader MA, Ganzer P, Colachis S, Zhang M, Mysiw WJ, Rezai AR, Sharma G (2018) A high definition non-invasive neuromuscular electrical stimulation system for cortical control of combinatorial rotary hand movements in a human with tetraplegia. IEEE Trans Biomed Eng. https://doi.org/10.1109/TBME.2018.2864104
Obhi SS, Hall P (2011) Sense of agency and intentional binding in joint action. Exp Brain Res 211:655–662
Wuolle KS, Doren CLV, Thrope GB, Keith MW, Peckham PH (1994) Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesis. J Hand Surg 19:209–342
Kumar N, Manjaly JA, Miyapuram KP (2014) Feedback about action performed can alter the sense of self-agency. Front Psychol 5:145
Funding
Financial support for this study came from Battelle Memorial Institute and The Ohio State University Center for Neuromodulation.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this chapter
Cite this chapter
Ganzer, P.D. et al. (2021). Restoring the Sense of Touch Using a Sensorimotor Demultiplexing Neural Interface: ‘Disentangling’ Sensorimotor Events During Brain-Computer Interface Control. In: Guger, C., Allison, B.Z., Gunduz, A. (eds) Brain-Computer Interface Research. SpringerBriefs in Electrical and Computer Engineering. Springer, Cham. https://doi.org/10.1007/978-3-030-79287-9_8
Download citation
DOI: https://doi.org/10.1007/978-3-030-79287-9_8
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-79286-2
Online ISBN: 978-3-030-79287-9
eBook Packages: Computer ScienceComputer Science (R0)