Abstract
The use of plane waves allows images with higher frame rates compared to conventional modes. Some studies have shown that the use of the Eigenspace Beamformer technique associated with the Generalized Sidelobe Canceler (EBGSC) reduces the effects of interference and noise, minimizing sidelobes and providing images with higher contrast and resolution compared to the Delay and Sum (DAS) and the Minimum Variance (MV) methods. Filters can also be applied after image processing to reduce speckle signals present in ultrasound images such as the Wiener and Kuan filter. This work presents the implementation of the EBGSC method with Wiener and Kuan filters to improve the processing of plane wave ultrasound images. The EBGSC method combined with Wiener filter (EBGSC-W) showed an improvement in the contrast of 70% and 57.2% when compared to the DAS and GSC methods, respectively. The geometric distortion was evaluated using the parameter of the full width at half maximum (FWHM) and the EBGSC-W also obtained a reduction in lateral FWHM by 63% and 25% compared to the DAS and GSC methods, respectively, approaching to the actual value of the target size (0.1 mm). The EBGSC method with the Kuan filter (EBGSC-K) showed improvements in the lateral FWHM, however, it worsened the contrast, with loss of information.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Montaldo G, Tanter M, Bercoff J et al (2009) Coherent planewave compounding for very high frame rate ultrasonography and transient elastography. IEEE Trans Ultrason Ferroelectr Freq Control 56:489–506
Bercoff J, Montaldo G, Loupas T et al (2011) Ultrafast compound doppler imaging: Providing full blood flow characterization. IEEE Trans Ultrason Ferroelectr Freq Control 58:134–147
Capon J (1969) High resolution frequency-wavenumber spectrum analysis. Proc IEEE 57:1408–1418
Li J, Chen X, Wang Y et al (2016) Eigenspace-based generalized sidelobe canceler beamforming applied to medical ultrasound imaging. Sensors 16:1192–2003. https://doi.org/10.3390/s16081192
Wu S, Zhu Q, Xie Y (2013) Evaluation of various speckle reduction filters on medical ultrasound images. In: 35th Annual international conference of the IEEE engineering in Medicine and Biology Society, Osaka, pp 1148–1151
Tasnim T, Shuvo MMH, Hasan S (2017) Study of speckle noise reduction from ultrasound B-mode images using different filtering techniques. In: 4th international conference on advances in electrical engineering, Dhaka, pp 229–234
Zimbico AJ, Granado DW, Schneider FK et al (2017) Beam domain adaptive beamforming using generalized sidelobe canceller with coherence factor for medical ultrasound imaging. In: IEEE international ultrasonics symposium, Washington, DC, pp 1–4
Neves LC, Zimbico AJ, Maia JM et al (2019) Adaptive beamformer with generalized sidelobe canceler for plane wave ultrasound image. In: XII symposium on biomedical engineering—IX symposium on instrumentation and medical images, Uberlândia, Brazil, pp 1–3
Zeng X, Chen C, Wang Y (2012) Eigenspace-based minimum variance beamformer combined with Wiener postfilter for medical ultrasound imaging. Ultrasonics 52:996–1004. https://doi.org/10.1016/j.ultras.2012.07.012
Aliabadi S, Wang J, Yu J (2016) Adaptive scaled wiener postfilter beamformer for ultrasound imaging. URSI Asia-Pacific radio science conference, Seoul, South Korea, pp 1449–1452
Jensen JA, Svendsen NB (1992) Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers. IEEE Trans Ultrason Ferroelectr Freq Control 39:262–267. https://doi.org/10.1109/58.139123
Jensen JA (1996) Field: a program for simulating ultrasound systems. Med Biol Eng Comput 34:351–353
The Ultrasound Toolbox at https://www.ustb.no/ius2017-abstract
Liebgott H, Rodriguez-Molares A, Cervenansky F et al (2016) Plane-wave imaging challenge in medical ultrasound. IEEE international ultrasonic symposium, Tours, France, pp 1–4
Applebaum S, Chapman D (1976) Adaptive arrays with main beam constraints. IEEE Trans Antennas Propag 24:650–662
Kuan D, Sawchuk A, Strand T et al (1987) Adaptive restoration of images with speckle. IEEE Trans Acous Speech Sig Process 35:373–383. https://doi.org/10.1109/TASSP.1987.1165131
Sivakumar R, Gayathri M K, Nedumaran D (2010) Speckle filtering of ultrasound B-scan images—a comparative study between spatial and diffusion filters. In: IEEE conference on open systems, Kuala Lumpur, Malaysia, pp 80–85
Acknowledgements
The authors would like to thank the Brazilian Agencies CAPES, CNPq, Fundação Araucária, FINEP and Ministry of Health for the financial support.
Conflict of Interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 Springer Nature Switzerland AG
About this paper
Cite this paper
Neves, L.C., Maia, J.M., Zimbico, A.J., Gomes, D.F., Assef, A.A., Costa, E.T. (2022). Eigenspace Beamformer Combined with Generalized Sidelobe Canceler and Filters for Generating Plane Wave Ultrasound Images. In: Bastos-Filho, T.F., de Oliveira Caldeira, E.M., Frizera-Neto, A. (eds) XXVII Brazilian Congress on Biomedical Engineering. CBEB 2020. IFMBE Proceedings, vol 83. Springer, Cham. https://doi.org/10.1007/978-3-030-70601-2_246
Download citation
DOI: https://doi.org/10.1007/978-3-030-70601-2_246
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-70600-5
Online ISBN: 978-3-030-70601-2
eBook Packages: EngineeringEngineering (R0)