Abstract
The kidney diseases are recognized by high levels of serum creatinine and blood urea nitrogen (BUN) caused by deteriorating glomerular ultrafiltration rate. These diseases are a serious problem and can be seen in individuals of any age and sex but significantly in old age populations. There is generally minor or no symptoms of kidney diseases are seen until significant loss of kidney function and/or disease states related to a kidney (renal) malfunction are worsen in individuals. The creatinine and BUN are considered as biomarkers for kidney healthcare. Ultrasound, CT scan, blood test, sedimentation of urine, the output of urine as well as a urinalysis test are standard techniques for measuring the serum electrolytes, serum creatinine, BUN and kidney function levels. Any of these tests are useful in the diagnosis of kidney diseases and their progression in each stage. They help in treatment methods and decisions associated with drug regiments. These techniques are also helpful in understanding the degree of improvement/declining status in diseased kidney healthcare after medical treatment. Since the noticeable changes in kidney disease stages (maintenance/progression/improvement) are very slow, therefore most of the drugs which are prescribed are useful in long term care of kidney health than that of faster healing of diseased stage. Due to the slower rate of kidney healthcare progression, the ultrasound and/or CT scan studies are needed after longer time intervals; where a medical practitioner can be able to distinguish the difference between previous and current kidney health status. Although the daily formation of the creatinine and BUN are constant, the noticeable changes in creatinine and BUN are visible in two weeks. That is why the detection and quantifying of biomarkers such as creatinine and BUN are of high significance. The level of BUN is also linked with other organ disease conditions but the rise in serum creatinine levels is specifically linked with kidney disease. Therefore, serum creatinine levels are highly useful with the ultrasound and/or CT scan to identify loss of kidney function and kidneys’ subsequent response to the drug regiments. Frequent visits to pathology labs are necessary but also inconvenient for kidney patients. Currently, there is the unavailability of techniques to detect levels of creatinine at home. Although blood testing is standardised for measurement of serum creatinine, it is invasive as it involves venepuncture. This method is time consuming, costly, requires pathology experts in venepuncture as well as for performing sample analysis, and the results are complicated for a patient to understand from home. Therefore, it is necessary to develop a home-based electrochemical biosensing detection system which is rapid, cost-effective, easily operable, interpretation and internet friendly Point-of-Care (PoC) diagnostic device sensing system. The PoC device can establish a trustable domestic measuring profile for kidney disease patients. The device can be utilised as a prognostic as well as a prophylactic care modem at a patient understanding level, that indicates the frequent minor changes in levels of serum creatinine thus helpful in kidney healthcare. This will help as an indicator to the patient and a medical practitioner in detecting changes in serum creatinine at early-stage thus helpful in better revival. In current work, we would like to describe our research on the development of highly specific polymer for the detection of creatinine from heat-inactivated serum samples and the making of electrochemical impedance spectroscopy (EIS)-based sensing system. The Molecularly Imprinted Polymer (MIP)-EIS combined system is further developed to make a home operable and internet connectable PoC diagnostic device and it has been cross-verified by using commercially developed Creatinine Colorimetric Assay Kit.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
An anterior, posterior view of human kidneys, https://y7177.com/sa/anato/uro/kidney/kidney.htm. Accessed 24 Jan 2019
A superior view of a transverse section of a human kidney, https://slideplayer.com/slide/12632070/. Accessed 24 Jan 2019
An ultrastructure of the nephron, https://www.britannica.com/science/nephron. Accessed 24 Jan 2019
Structure and Functioning of Kidneys, Renal Health with Creatinine Levels, https://www.alilamedicalimages.org/BrowseImages/browse-topics/urology-browse-topics/. Accessed 23 Jan 2019
A.D. Paul, C. Girish, T.N. Shilpa, K. Manogna, A.G. Susmitha, Renal vascularisation causing end-stage failures and outcomes: a pooled analysis of community-based studies. Int. J. Pharm. Sci. Drug Res. 9(5), 256–262 (2017)
M. Wyss, R. Kaddurah-Daouk, Creatine and creatinine metabolism. Physiol. Rev. 80, 1107–1213 (2000)
Levels of creatinine, https://www.medicinenet.com/creatinine_blood_test/article.htm#what_are_considered_high_creatinine_levels. Accessed 24 Jan 2019
Kidney Damage (Acute Renal Failure), https://cancer.unm.edu/cancer/cancer-info/cancertreatment/side-effects-of-cancer-treatment/less-common-sideeffects/organ-problems/kidney-damage-acute-renal-failure/#_edn1. Accessed 25 Jan 2019
J.P. Cata, A.M. Zavala, A.V. Meter, U.U. Williams, J. Soliz, M. Hernandez, P. Owusu-Agyemang, Identification of risk factors associated with postoperative acute kidney injury after cytoreductive surgery with hyperthermic intraperitoneal chemotherapy: a retrospective study. Int. J. Hyperth. Therm. Ther. 34, 538–544 (2018)
T. Dagel, S. Misirlioglu, S. Tanju, B. Afsar, F. Selcukbiricik, S. Erus, D. Vatansever, E. Balik, C. Taskiran, S. Dilege, N.M. Mandel, D. Bugra, T. Yalti, M. Kanbay, Hyperthermic intraperitoneal chemotherapy is an independent risk factor for development of acute kidney injury. J. Balkan Union Oncol 23, 1528–1533 (2018)
D. Katagiri, E. Noiri, R. Matsuura, R.C. Harris, Acute kidney injury: transition to chronic kidney disease. Hum. Pathobiochem. 269–277 (2019)
H. Izzedine, M.A. Perazella, Anticancer drug-induced acute kidney injury. Kidney Int. Rep. 2, 504–514 (2017)
M. Aapro, V. Launay-Vacher, Importance of monitoring renal function in patients with cancer. J. Cancer Treat. Rev. 38, 235–240 (2012)
V. Sahni, D. Choudhury, Z. Ahmed, Chemotherapy-associated renal dysfunction. Nat. Rev. Nephrol. 5, 450–462 (2009)
S.L. Kane-Gill, S.L. Goldstein, Drug-induced acute kidney injury: a focus on risk assessment for prevention. Crit. Care Clin. 31, 675–684 (2015)
G.S. Pazhyattil, A.C. Shirali, Drug-induced impairment of renal function. Int. J. Nephrol. Renovasc. Dis. 7, 457–468 (2014)
I. Glezerman, M.G. Kris, V. Miller, S. Seshan, C.D. Flombaum, Gemcitabine nephrotoxicity and hemolytic uremic syndrome: report of 29 cases from a single institution. Clin. Nephrol. 71, 130–139 (2009)
J. Radhakrishnan, M.A. Perazella, Drug-induced glomerular disease: attention required! Clin. J. Am. Soc. Nephrol. 10, 1287–1290 (2015)
V. Launay-Vacher, S. Oudard, N. Janus, J. Gligorov, X. Pourrat, O. Rixe, J. Morere, P. Beuzeboc, G. Deray, Prevalence of renal insufficiency in cancer patients and implications for anticancer drug management. Cancer 110, 1376–1384 (2007)
A.S. Abu-Abed, R.G. Lindquist, Capacitive interdigital sensor with inhomogeneous nematic liquid crystal film. Progress Electromag. Res. 75–87 (2008)
A.V. Mamishev, K. Sundara-Rajan, F. Yang, Y. Du, M. Zahn, Interdigital sensors and transducers. Proc. IEEE 808–845 (2004)
Y. Chen, C. Zhu, M. Cao, T. Wang, Photoresponse of SnO2 nanobelts grown in situ on interdigital electrodes. Nanotechnology 18, 285–502 (2007)
M.S.A. Rahman, S.C. Mukhopadhyay, P.-L. Yu, Novel planar interdigital sensors, in Novel Sensors for Food Inspection: Modelling, Fabrication and Experimentation (Springer, 2014), pp. 11–35
A.M. Syaifudin, K. Jayasundera, S. Mukhopadhyay, A low cost novel sensing system for detection of dangerous marine biotoxins in seafood. Sens. Actuators: B Chem. 137, 67–75 (2009)
A.M. Syaifudin, S. Mukhopadhyay, P. Yu, Electromagnetic field computation using COMSOL multiphysics to evaluate the performance of novel interdigital sensors. Appl. Electromag. Conf. AEMC 2009, 1–4 (2009)
A.M. Syaifudin, M. Yunus, S. Mukhopadhyay, K. Jayasundera, A novel planar interdigital sensor for environmental monitoring, Sens. IEEE, 105–110 (2009)
S.N. Prabhu, S.C. Mukhopadhyay, C. Gooneratne, A.S. Davidson G. Liu,Interdigital sensing system for detection of levels of creatinine from the samples, in2019 13th International Conference on Sensing Technology (ICST) (2019), pp. 1–6
M.S. Abdul Rahman, S.C. Mukhopadhyay, P.-L. Yu, Novel planar interdigital sensors, in Novel Sensors for Food Inspection: Modelling, Fabrication and Experimentation. Smart Sensors, Measurement and Instrumentation, vol. 10 (Springer, 2014)
Y. Yang, G. Chiesura, G. Luyckx, T. Vervust, F. Bossuyt, J. Vanfleteren et al., In situ on-line cure monitoring of composites by embedded interdigital sensor, in 16th European Conference on Composite Materials (ECCM-16) (2014)
A.I. Zia, A.M. Syaifudin, S. Mukhopadhyay, P. Yu, I. Al-Bahadly, C.P. Gooneratne et al., Electrochemical impedance spectroscopy based MEMS sensors for phthalates detection in water and juices. J. Phys Conf. Ser. 012–026 (2013)
A.I. Zia, S.C. Mukhopadhyay, P.-L. Yu, I. Al-Bahadly, C.P. Gooneratne, J. Kosel, Rapid and molecular selective electrochemical sensing of phthalates in aqueous solution. Biosens. Bioelectron. 67, 342–349 (2015)
A. Zia, S. Mukhopadhyay, I. Al-Bahadly, P. Yu, C.P. Gooneratne, J. Kosel, Introducing molecular selectivity in rapid impedimetric sensing of phthalates, in Instrumentation and Measurement Technology Conference (I2MTC) Proceedings, 2014 IEEE International (2014), pp. 838–843
A. Syaifudin, K. Jayasundera, S. Mukhopadhyay, A novel planar interdigital sensor based sensing and instrumentation for detection of dangerous contaminated chemical in seafood, in Instrumentation and Measurement Technology Conference, I2MTC’09 (IEEE, 2009), pp. 701–706
J. Fischer, H. Dejmkova, J. Barek, Electrochemistry of pesticides and its analytical applications. Curr. Org. Chem. 15, 2923–2935 (2011)
M. Khafaji, S. Shahrokhian, M. Ghalkhani, Electrochemistry of levo-thyroxin on edge-plane pyrolytic graphite electrode: application to sensitive analytical determinations. Electroanalysis 23, 1875–1880 (2011)
L. Li, F. Yang, J. Yu, X. Wang, L. Zhang, Y. Chen et al., In situ growth of ZnO nanowires on Zn comb-shaped interdigitating electrodes and their photosensitive and gas-sensing characteristics. Mat. Res. Bull. 47, 3971–3975 (2012)
M. Dhull, A. Arora, Design of MEMS based microheater for enhanced efficiency of gas sensors. J. Therm. Sci. Eng. Appl. 2, 16–21 (2015)
S.C. Mukhopadhyay, C.P. Gooneratne, A novel planar-type biosensor for noninvasive meat inspection. IEEE Sens. J. 7, 1340–1346 (2007)
M.S.A. Rahman, S.C. Mukhopadhyay, P.-L. Yu, J. Goicoechea, I.R. Matias, C.P. Gooneratne et al., Detection of bacterial endotoxin in food: New planar interdigital sensors based approach. J. Food Eng. 114, 346–360 (2013)
C. Xhoffer, K. Van den Bergh, H. Dillen, Electrochemistry: a powerful analytical tool in steel research. Electrochim. Acta 49, 2825–2831 (2004)
C.V. Vidal, A.I. Muñoz, Effect of physico-chemical properties of simulated body fluids on the electrochemical behaviour of CoCrMo alloy. Electrochim. Acta 56, 8239–8248 (2011)
X. Li, K. Toyoda, I. Ihara, Coagulation process of soymilk characterized by electrical impedance spectroscopy. J. Food Eng. 105, 563–568 (2011)
C. Liu, Q. Bi, A. Leyland, A. Matthews, An electrochemical impedance spectroscopy study of the corrosion behaviour of PVD coated steels in 0.5 N NaCl aqueous solution: Part II.: EIS interpretation of corrosion behaviour. Corros. Sci. 45, 1257–1273 (2003)
A. Ghasemi, V. Raja, C. Blawert, W. Dietzel, K. Kainer, Study of the structure and corrosion behavior of PEO coatings on AM50 magnesium alloy by electrochemical impedance spectroscopy. Surf. Coat. Technol. 202, 3513–3518 (2008)
R.M. Souto, M.A.M. Laz, R.L. Reis, Degradation characteristics of hydroxyapatite coatings on orthopaedic TiAlV in simulated physiological media investigated by electrochemical impedance spectroscopy. Biomaterials 24, 4213–4221 (2003)
D. Andre, M. Meiler, K. Steiner, C. Wimmer, T. Soczka-Guth, D. Sauer, “Characterization of high-power lithium-ion batteries by electrochemical impedance spectroscopy, I. Experimental investigation. J. Power Sour. 196, 5334–5341 (2011)
F. Lisdat, D. Schäfer, The use of electrochemical impedance spectroscopy for biosensing. Anal. Bioanal. Chem. 391, 1555–1567 (2008)
B.-Y. Chang, S.-M. Park, Electrochemical impedance spectroscopy. Annu. Revi. Anal. Chem. 3, 207–229 (2010)
G. Instruments, Basics of electrochemical impedance spectroscopy. Gamry Inst. Complex Impedance Corros. 130 (2007)
I.I. Suni, Impedance methods for electrochemical sensors using nanomaterials. Trends Anal. Chem. 27, 604–611 (2008)
J.R. Macdonald, E. Barsoukov, Impedance spectroscopy: theory, experiment, and applications. History 1 8 (2005)
J.E.B. Randles, Kinetics of rapid electrode reactions. Discuss. Faraday Soc. 1, 11–19 (1947)
K. Haupt, A.V. Linares, M. Bompart, B.T.S. Bui, Molecularly imprinted polymers, in Molecular Imprinting (Springer: Berlin/Heidelberg, Germany, 2012), pp. 1–28
M.J. Whitcombe, N. Kirsch, I. Nicholls, A. Molecular imprinting science and technology: A survey of the literature for the years 2004–2011. J. Mol. Recognit. 27, 297–401 (2014)
S.N. Prabhu, S.C. Mukhopadhyay, A.S. Davidson, G. Liu,Highly selective molecularly imprinted polymer for creatinine detection, in 2019 13th International Conference on Sensing Technology (ICST) (Sydney, Australia, 2019), pp. 1–5
Analog Devices AD5933: Impedance Analyzer, https://www.analog.com/media/en/technicaldocumentation/datasheets/AD5933.pdf. Accessed 9 Feb 2020
S. Prabhu, C. Gooneratne, K.A. Hoang, S. Mukhopadhyay, IoT-associated impedimetric biosensing for point-of-care monitoring of kidney health. IEEE Sens. J. (2020)
Creatinine Colorimetric Assay Kit, https://www.abcam.com/ps/products/65/ab65333/documents/ab65333%20Glucose%20Assay%20kit%20Protocol%20v11a%20(website).pdf. Accessed 10 Feb 2020
A. Zia, A. Syaifudin, S. Mukhopadhyay, I.H. Al-Bahadly, P. Yu, C.P. Gooneratne et al., MEMS based impedimetric sensing of phthalates, in 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), IEEE International (2013), 855–860
M.S. Abdul Rahman, S.C. Mukhopadhyay, P.-L. Yu, J. Goicoechea, I.R. Matias, C.P. Gooneratne et al., Detection of bacterial endotoxin in food: new planar interdigital sensors based approach. J. Food Eng. 114, 346–360 (2013)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Switzerland AG
About this chapter
Cite this chapter
Prabhu, S.N., Gooneratne, C.P., Hoang, K.A., Mukhopadhyay, S.C., Davidson, A.S., Liu, G. (2021). Interdigital Sensing System for Kidney Health Monitoring. In: Mukhopadhyay, S.C., George, B., Roy, J.K., Islam, T. (eds) Interdigital Sensors. Smart Sensors, Measurement and Instrumentation, vol 36. Springer, Cham. https://doi.org/10.1007/978-3-030-62684-6_11
Download citation
DOI: https://doi.org/10.1007/978-3-030-62684-6_11
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-62683-9
Online ISBN: 978-3-030-62684-6
eBook Packages: EngineeringEngineering (R0)