The application of phase-contrast imaging to breast cancer detection has always been a driving force in the development of phase-sensitive techniques. By making use of the physical foundations of propagation-based imaging previously introduced, this chapter is focused on the specific application in the field of breast computed tomography.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ferlay J, Soerjomataram I, Dikshit R, Eser S, Mathers C, Rebelo M, Parkin DM, Forman D, Bray F (2015) Cancer incidence and mortality worldwide: sources, methods and major patterns in GLOBOCAN 2012. Int J Cancer 136(5):E359–E386. https://doi.org/10.1002/ijc.29210

    Article  Google Scholar 

  2. Siegel RL, Miller KD, Jemal A (2016) Cancer statistics, 2016. CA Cancer J Clin 66(1):7–30. https://doi.org/10.3322/caac.21332

  3. Tanaka T, Honda C, Matsuo S, Noma K, Oohara H, Nitta N, Ota S, Tsuchiya K, Sakashita Y, Yamada A et al (2005) The first trial of phase contrast imaging for digital full-field mammography using a practical molybdenum X-ray tube. Invest Radiol 40(7):385–396. https://doi.org/10.1097/01.rli.0000165575.43381.48

    Article  Google Scholar 

  4. Castelli E, Tonutti M, Arfelli F, Longo R, Quaia E, Rigon L, Sanabor D, Zanconati F, Dreossi D, Abrami A et al (2011) Mammography with synchrotron radiation: first clinical experience with phase-detection technique. Radiology 259(3):684–694. https://doi.org/10.1148/radiol.11100745

    Article  Google Scholar 

  5. Morita T, Yamada M, Kano A, Nagatsuka S, Honda C, Endo T (2008) A comparison between film-screen mammography and full-field digital mammography utilizing phase contrast technology in breast cancer screening programs. In: International workshop on digital mammography. Springer, pp 48–54. https://doi.org/10.1007/978-3-540-70538-3_7

  6. Longo R, Tonutti M, Rigon L, Arfelli F, Dreossi D, Quai E, Zanconati F, Castelli E, Tromba G, Cova MA (2014) Clinical study in phase-contrast mammography: image-quality analysis. Phil Trans R Soc A 372(2010):20130025. https://doi.org/10.1098/rsta.2013.0025

    Article  ADS  Google Scholar 

  7. Fedon C, Rigon L, Arfelli F, Dreossi D, Quai E, Tonutti M, Tromba G, Cova MA, Longo R (2018) Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report. J Med Imaging 5(1):013503. https://doi.org/10.1117/1.JMI.5.1.013503

    Article  Google Scholar 

  8. Sechopoulos I (2013) A review of breast tomosynthesis. Part I, the image acquisition process. Med Phys 40(1). https://doi.org/10.1118/1.4770279

  9. McDonald ES, Oustimov A, Weinstein SP, Synnestvedt MB, Schnall M, Conant EF (2016) Effectiveness of digital breast tomosynthesis compared with digital mammography: outcomes analysis from 3 years of breast cancer screening. JAMA Oncol 2(6):737–743. https://doi.org/10.1001/jamaoncol.2015.5536

    Article  Google Scholar 

  10. Lång K, Andersson I, Rosso A, Tingberg A, Timberg P, Zackrisson S (2016) Performance of one-view breast tomosynthesis as a stand-alone breast cancer screening modality: results from the malmö breast tomosynthesis screening trial, a population-based study. Eur Radiol 26(1):184–190. https://doi.org/10.1007/s00330-015-3803-3

    Article  Google Scholar 

  11. Phi X-A, Tagliafico A, Houssami N, Greuter MJ, de Bock GH (2018) Digital breast tomosynthesis for breast cancer screening and diagnosis in women with dense breasts—a systematic review and meta-analysis. BMC Cancer 18(1):380. https://doi.org/10.1186/s12885-018-4263-3

    Article  Google Scholar 

  12. Boone JM, Nelson TR, Lindfors KK, Seibert JA (2001) Dedicated breast CT: radiation dose and image quality evaluation. Radiology 221(3):657–667. https://doi.org/10.1148/radiol.2213010334

    Article  Google Scholar 

  13. Lindfors KK, Boone JM, Nelson TR, Yang K, Kwan AL, Miller DF (2008) Dedicated breast CT: initial clinical experience. Radiology 246(3):725–733. https://doi.org/10.1148/radiol.2463070410

    Article  Google Scholar 

  14. Lindfors KK, Boone JM, Newell MS, D’Orsi CJ (2010) Dedicated breast computed tomography: the optimal cross-sectional imaging solution? Radiol Clin 48(5):1043–1054. https://doi.org/10.1016/j.rcl.2010.06.001

    Article  Google Scholar 

  15. O’Connell A, Conover DL, Zhang Y, Seifert P, Logan-Young W, Lin C-FL, Sahler L, Ning R (2010) Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality. Am J Roentgenol 195(2):496–509. https://doi.org/10.2214/AJR.08.1017

    Article  Google Scholar 

  16. Sechopoulos I, Feng SSJ, D’Orsi CJ (2010) Dosimetric characterization of a dedicated breast computed tomography clinical prototype. Med Phys 37(8):4110–4120. https://doi.org/10.1118/1.3457331

    Article  Google Scholar 

  17. Kalender WA, Beister M, Boone JM, Kolditz D, Vollmar SV, Weigel MC (2012) High-resolution spiral CT of the breast at very low dose: concept and feasibility considerations. Eur Radiol 22(1):1–8. https://doi.org/10.1007/s00330-011-2169-4

    Article  Google Scholar 

  18. Papas MA, Klassen AC (2005) Pain and discomfort associated with mammography among urban low-income african–american women. J Commun Health 30(4):253–267. https://doi.org/10.1007/s10900-005-3704-5

    Article  Google Scholar 

  19. Evans RD (1955) The atomic nucleus. McGraw-Hill New York. https://doi.org/10.1002/aic.690020327

  20. Delogu P, Di Trapani V, Brombal L, Mettivier G, Taibi A, Oliva P (2019) Optimization of the energy for breast monochromatic absorption X-ray computed tomography. Sci Rep 9(1):1–10. https://doi.org/10.1038/s41598-019-49351-2

    Article  Google Scholar 

  21. Koning C (2018) Koning breast CT. http://koninghealth.com/en/kbct/

  22. Kalender WA, Kolditz D, Steiding C, Ruth V, Lück F, Rößler A-C, Wenkel E (2017) Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast. Eur Radiol 27(3):1081–1086. https://doi.org/10.1007/s00330-016-4459-3

    Article  Google Scholar 

  23. Berger N, Marcon M, Saltybaeva N, Kalender WA, Alkadhi H, Frauenfelder T, Boss A (2019) Dedicated breast computed tomography with a photon-counting detector: initial results of clinical in vivo imaging. Invest Radiol. https://doi.org/10.1097/RLI.0000000000000552

    Article  Google Scholar 

  24. AB-CT (2019) Advanced breast-CT. https://www.ab-ct.com/nuview/

  25. O’Connell AM, Karellas A, Vedantham S (2014) The potential role of dedicated 3d breast CT as a diagnostic tool: review and early clinical examples. Breast J 20(6):592–605. https://doi.org/10.1111/tbj.12327

    Article  Google Scholar 

  26. Wienbeck S, Lotz J, Fischer U (2017) Review of clinical studies and first clinical experiences with a commercially available cone-beam breast CT in Europe. Clin Imaging 42:50–59. https://doi.org/10.1016/j.clinimag.2016.11.011

    Article  Google Scholar 

  27. Uhlig J, Uhlig A, Biggemann L, Fischer U, Lotz J, Wienbeck S (2019) Diagnostic accuracy of cone-beam breast computed tomography: a systematic review and diagnostic meta-analysis. Eur Radiol 29(3):1194–1202. https://doi.org/10.1007/s00330-018-5711-9

    Article  Google Scholar 

  28. Sarno A, Mettivier G, Russo P (2015) Dedicated breast computed tomography: basic aspects. Med Phys 42(6Part1):2786–2804. https://doi.org/10.1118/1.4919441

  29. Sechopoulos I (2012) X-ray scatter correction method for dedicated breast computed tomography. Med Phys 39(5):2896–2903. https://doi.org/10.1118/1.4711749

    Article  Google Scholar 

  30. Longo R, Arfelli F, Bellazzini R, Bottigli U, Brez A, Brun F, Brunetti A, Delogu P, Di Lillo F, Dreossi D et al (2016) Towards breast tomography with synchrotron radiation at elettra: first images. Phys Med Biol 61(4):1634. https://doi.org/10.1088/0031-9155/61/4/1634

    Article  Google Scholar 

  31. Rößler A, Wenkel E, Althoff F, Kalender W (2015) The influence of patient positioning in breast CT on breast tissue coverage and patient comfort. Senologie-Zeitschrift für Mammadiagnostik und-therapie 12(02):96–103. https://doi.org/10.1055/s-0034-1385208

    Article  Google Scholar 

  32. Arfelli F, Assante M, Bonvicini V, Bravin A, Cantatore G, Castelli E, Dalla Palma L, Di Michiel M, Longo R, Olivo A et al (1998) Low-dose phase contrast X-ray medical imaging. Phys Med Biol 43(10):2845. https://doi.org/10.1088/0031-9155/43/10/013

  33. Abrami A, Arfelli F, Barroso R, Bergamaschi A, Bille F, Bregant P, Brizzi F, Casarin K, Castelli E, Chenda V et al (2005) Medical applications of synchrotron radiation at the syrmep beamline of elettra. Nucl Instrum Methods Phys Res Sect A Accel Spectrom Detectors and Assoc Equip 548(1–2):221–227. https://doi.org/10.1016/j.nima.2005.03.093

    Article  ADS  Google Scholar 

  34. Tromba G, Longo R, Abrami A, Arfelli F, Astolfo A, Bregant P, Brun F, Casarin K, Chenda V, Dreossi D (2010). The syrmep beamline of elettra: clinical mammography and bio-medical applications. In: AIP conference proceedings, vol 1266. AIP, pp 18–23. https://doi.org/10.1063/1.3478190

  35. Brombal L, Golosio B, Arfelli F, Bonazza D, Contillo A, Delogu P, Donato S, Mettivier G, Oliva P, Rigon L et al (2018c) Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction. J Med Imaging 6(3):031402. https://doi.org/10.1117/1.JMI.6.3.031402

    Article  Google Scholar 

  36. Longo R, Arfell F, Bonazza D, Bottigli U, Brombal L, Contillo A, Cova M, Delogu P, Di Lillo F, Di Trapani V et al (2019) Advancements towards the implementation of clinical phase-contrast breast computed tomography at elettra. J Synchrotron Radiat 26(4). https://doi.org/10.1107/S1600577519005502

  37. Longo R, Abrami A, Arfelli F, Bregant P, Chenda V, Cova MA, Dreossi D, De Guarrini F, Menk R, Quai E et al (2007) Phase contrast mammography with synchrotron radiation: physical aspects of the clinical trial. In: International Society for Optics and Photonics on Medical Imaging 2007: Physics of Medical Imaging, vol 6510, p 65100T. https://doi.org/10.1117/12.708403

  38. Delogu P, Golosio B, Fedon C, Arfelli F, Bellazzini R, Brez A, Brun F, Di Lillo F, Dreossi D, Mettivier G et al (2017b) Imaging study of a phase-sensitive breast-CT system in continuous acquisition mode. J Instrum 12(01):C01016. https://doi.org/10.1088/1748-0221/12/01/C01016

    Article  Google Scholar 

  39. Taba ST, Baran P, Lewis S, Heard R, Pacile S, Nesterets YI, Mayo SC, Dullin C, Dreossi D, Arfelli F et al (2019) Toward improving breast cancer imaging: radiological assessment of propagation-based phase-contrast CT technology. Acad Radiol 26(6):e79–e89. https://doi.org/10.1016/j.acra.2018.07.008

    Article  Google Scholar 

  40. Bellazzini R, Spandre G, Brez A, Minuti M, Pinchera M, Mozzo P (2013) Chromatic X-ray imaging with a fine pitch cdte sensor coupled to a large area photon counting pixel asic. J Instrum 8(02):C02028. https://doi.org/10.1088/1748-0221/8/02/C02028

    Article  Google Scholar 

  41. Burns D, Toni M, Bovi M (1999) Comparison of the air-kerma standards of the enea-inmri and the bipm in the low-energy X-ray range. Technical Report BIPM-99/11, Bureau International des Poids et Mesures

    Google Scholar 

  42. Bovi M, Laitano R, Pimpinella M, Toni M, Casarin K, Quail E, Tromba G, Vacotto A, Dreossi D (2007) Absolute air-kerma measurement in a synchrotron light beam by ionization free-air chamber. In: Workshop on Absorbed dose and air kerma primary standards, Paris

    Google Scholar 

  43. Bovi M, Laitano R, Pimpinella M, Toni M, Casarin K, Tromba G, Vascotto A (2009) Misure assolute di kerma in aria del fascio di luce di sincrotrone prodotto presso l’impianto elettra di trieste per applicazioni nella diagnostica medica ad alta risoluzione. In: Proceedings of the 6th Conference “Metrologia & Qualità”, Turin, Italy, pp 7–9

    Google Scholar 

  44. Mettivier G, Fedon C, Di Lillo F, Longo R, Sarno A, Tromba G, Russo P (2015) Glandular dose in breast computed tomography with synchrotron radiation. Phys Med Biol 61(2):569. https://doi.org/10.1088/0031-9155/61/2/569

    Article  Google Scholar 

  45. Fedon C, Longo F, Mettivier G, Longo R (2015) Geant4 for breast dosimetry: parameters optimization study. Phys Med Biol 60(16):N311. https://doi.org/10.1088/0031-9155/60/16/N311

    Article  Google Scholar 

  46. Brun F, Pacilè S, Accardo A, Kourousias G, Dreossi D, Mancini L, Tromba G, Pugliese R (2015) Enhanced and flexible software tools for X-ray computed tomography at the italian synchrotron radiation facility elettra. Fundamenta Informaticae 141(2–3):233–243. https://doi.org/10.3233/FI-2015-1273

    Article  MathSciNet  MATH  Google Scholar 

  47. Contillo A, Veronese A, Brombal L, Donato S, Rigon L, Taibi A, Tromba G, Longo R, Arfelli F (2018) A proposal for a quality control protocol in breast CT with synchrotron radiation. Radiol Oncol 52(3):1–8. https://doi.org/10.2478/raon-2018-0015

    Article  Google Scholar 

  48. Piai A, Contillo A, Arfelli F, Bonazza D, Brombal L, Cova MA, Delogu P, Trapani VD, Donato S, Golosio B, Mettivier G, Oliva P, Rigon L, Taibi A, Tonutti M, Tromba G, Zanconati F, Longo R (2019) Quantitative characterization of breast tissues with dedicated CT imaging. Phys Med Biol 64(15):155011. https://doi.org/10.1088/1361-6560/ab2c29

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Luca Brombal .

Rights and permissions

Reprints and permissions

Copyright information

© 2020 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Brombal, L. (2020). Propagation-Based Breast CT and SYRMA-3D Project. In: X-Ray Phase-Contrast Tomography. Springer Theses. Springer, Cham. https://doi.org/10.1007/978-3-030-60433-2_3

Download citation

Publish with us

Policies and ethics